Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Size: px
Start display at page:

Download "Yes You Can! New! Amazing EVO C18. Core-Shell Technology"

Transcription

1 Core-Shell Technology Yes You Can! New! Amazing EVO C8 Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity

2 THE PAST Fully Porous You used to have to deal with chromatographic band broadening, low sensitivity, and long run times caused by classical fully porous silica. More Band Broadening And don t forget about system dependency and extremely high backpressure caused by me! Sub- µm Phenomenex l WEB:

3 Core-Shell Technology THE PRESENT Core-Shell Technology That was until Phenomenex, the leading Core-Shell Technology developer and manufacturer, came to liberate you with core-shell particles for each of your specific techniques and applications. Less Band Broadening Improved Results Increased Productivity Easy Transferability Significant Cost Savings 9 Small Molecules Synthetic Oligonucleotides Peptides / Proteins And Now Core-Shell Technology

4 AMAZING NEW KINETEX EVO, NOW! Introducing Kinetex EVO This is truly the next step in the evolution of the chromatographic particle. With Kinetex EVO you now have the freedom to achieve improved results, cost savings, and overall higher productivity at low, neutral, and high ph! O O O O O O O Si Si O Si S Si O Si O Si Si O O O O O O O O C Si O Si Si O Si Si O Si Si O Si C O O O O O O O O C O Si Si O Si Si O Si Si O Si Si O O O O O O Kinetex EVO uses a patented organo-silica grafting process which incorporates uniform stabilizing ethane cross-linking to provide resistance to high ph attack while maintaining mechanical strength of the core-shell particle. Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity Phenomenex l WEB:

5 Core-Shell Technology What emotion will Kinetex EVO bring out in you... STRENGTH... pp. 6-7 TRUST... pp. 8-9 PRIDE...p. CONFIDENCE...p. HAPPINESS... pp. - WONDER... pp. - DESIRE... pp. 6-7 ZEST... pp. 8-9 LOVE... pp. - EVO

6 STRENGTH ph at Your Control While low ph mobile phases are quite useful, once the door to both low and high ph is opened, your method development options rapidly increase. The illustrations below exemplify how easy it can be to influence the retention behavior and peak shape of ionizable compounds by adjusting your mobile phase ph. Effects of mobile phase ph on Acids Effects of mobile phase ph on Bases Below pk a Low ph Below pk a At pk a At pk a Above pk a High ph Above pk a 6 Phenomenex l WEB:

7 Core-Shell Technology STRENGTH Show Those Peaks Who s Boss With excellent performance across a large ph range, Kinetex EVO columns allow you to transform chromatograms and manipulate retention order, no matter the combination of compound functionalities. Now is your chance to break the mold and let your creative LC side flourish ph. ph 7 6 APP ID 7 APP ID Conditions for all columns: Column: Kinetex µm EVO C8 Dimensions: x.6 mm Part No.: F-6-E Mobile Phase: A: mm Potassium Phosphate B: Acetonitrile Gradient: -7 % B in utes Flow Rate:. ml/ Temperature: C Detection: nm Sample:. Ibuprofen. Diphenhydrae. Ethyl Benzene 7 6 ph APP ID

8 TRUST Rugged and Wonderful With its unique chemistry, the Kinetex EVO particle ensures improved ph stability at alkaline mobile phase conditions along with amazing core-shell performance. It s time for you to expand your method development options and go where other core-shell products can t! % High ph Stability % % Initial Efficiency for Amitriptyline 9% 8% 7% 6% % % Injection Cycle Conditions for all columns: Column: Kinetex μm EVO C8 Poroshell.7 μm HPH-C8 UltraCore μm Super C8 Dimensions: x. mm Mobile Phase: A: mm Ammonium bicarbonate (ph.) B: Acetonitrile Gradient: % to 9% B in.. Hold at 9 % B for.7. Re-equilibrate at % B for.. Flow Rate:.8 ml/ Temperature: 6 C Detection: nm Sample:. Amitriptyline Kinetex µm EVO C8 Agilent Poroshell.7 µm HPH-C8 ACE UltraCore µm Super C8 Agilent and Poroshell are registered trademarks of Agilent Technologies, Inc. ACE is a registered trademark and UltraCore is a trademark of Advanced Chromatography Technologies Limited. Phenomenex is not affiliated with any of the above listed companies. Comparative separations may not be representative of all applications. 8 Phenomenex l WEB:

9 Core-Shell Technology TRUST Dependability Batch-to-Batch, Column-to-Column Exceptionally rigorous quality control and manufacturing steps ensure that Kinetex EVO columns deliver the pinnacle of performance values and mechanical strength time after time. Simply put, that s reproducibility that you can trust and feel at ease with! 7 One of Many Internal Batch/Column QC Tests Customer Example Run-to-Run Consistency Batch Batch 7 APP ID 7 APP ID 7 7, st Injection 6 th Injection APP ID 7 6 Batch APP ID 7, 6 APP ID 7 Column: Kinetex µm EVO C8 Dimensions: x.6 mm Part No.: F-6-E Mobile Phase: A:. % Formic acid in Water B:. % Formic acid in Acetonitrile Gradient: -9 % B in 7.76 utes Flow Rate:. ml/ Temperature: C Detection: nm Sample:. Uracil. Pindolol. Chlorphenirae. Nortriptyline. -Methyl--Nitrobenzoic acid 6. -hydroxy,-methylbenzaldehyde 7. Hexanophenone Column: Kinetex µm EVO C8 Dimensions: x. mm Part No.: B-6-AN Mobile Phase: A:. % Ethanolae in Water (ph~.) B:. % Ethanolae in Acetonitrile Gradient: Time () Flow Rate:. ml/ Temperature: C Detection: nm % B 9 Sample:. Pyridine. Aniline. Unknown peak. Benzyl alcohol. Toluene 6. Unknown peak Data Courtesy of: Róbert Kormány, Egis Pharmaceuticals Plc., Hungary 9

10 PRIDE Wow! Look at those Marvelous Peak Shapes! You re going to be the talk of the lab and department when you switch to Kinetex EVO for your basic compound analyses. The unique organo-silica layer of ethane cross-linking found within each Kinetex EVO particle creates a highly inert surface which provides the additional benefit of better peak shape for bases. Kinetex µm EVO C8 x.6 mm Pressure: 76 bar Peak Capacity: 69 Supelco Ascentis Express µm C8 x.6 mm Pressure: bar Peak Capacity: 87 APP ID 76 APP ID Conditions for all columns: Column: Kinetex µm EVO C8 Ascentis Express µm C8 Dimensions: x.6 mm Mobile Phase: A: mm Sodium phosphate dehydrate ph 7. B: Methanol Gradient: % to 9 % B over utes Flow Rate: ml/ Temperature: Ambient Detection: Sample:. Scopolae. Pseudoephedrine. Doxylae. Chlorphenirae. Diphenhydrae Ascentis and Supelco are registered trademarks of Sigma-Aldrich Co. Phenomenex is not affiliated with any of the above listed companies. Comparative separations may not be representative of all applications. Phenomenex l WEB:

11 Core-Shell Technology CONFIDENCE Do More Load-to-Load Use Kinetex EVO columns to avoid the effects of peak shape distortion for bases that traditional fully porous and core-shell columns display. Even across multiple loading conditions, sharp compound peak shape is kept consistently good and strong using a Kinetex EVO LC column. Core-Shell µm C8 Kinetex µm EVO C APP ID 76 APP ID 77 Conditions for all columns: Column: Kinetex µm EVO C8 Core-Shell µm C8 Dimensions: x.6 mm Mobile Phase:. % TFA in Water /. % TFA in Acetonitrile (:6) Flow Rate:. ml/ Temperature: Ambient Detection: Sample: µg to µg Loads of Nortriptyline

12 HAPPINESS Instant Improvement of µm and µm Methods Now you can cheerfully improve the resolution, productivity, and sensitivity of your current µm and µm methods using Kinetex EVO µm Core-Shell Technology. This revolutionary coreshell particle was specifically developed to give you great performance and true ph durability at very low HPLC backpressures. Up to 9 % higher average efficiency Up to % higher average efficiency at half the pressure µm VS. µm VS. Fully Porous µm Fully Porous µm Kinetex EVO Core-Shell Kinetex EVO Core-Shell Phenomenex l WEB:

13 Core-Shell Technology HAPPINESS Drop in a Kinetex EVO µm Column to Start Smiling With the combination of rugged ph stability from - and the core-shell performance advantage, you can easily replace old hybrid silica columns and gain immediate method improvements without increasing backpressure. It s time to let chromatography cheer appear! Kinetex µm EVO C8 x.6 mm 6 Pressure: bar Waters XBridge. µm C8 x.6 mm Pressure: 6 bar APP ID APP ID Conditions for all columns: Column: Kinetex µm EVO C8 XBridge µm C8 XBridge. µm C8 Dimensions: x.6 mm Mobile Phase: A:. % Formic acid in Water B:. % Formic acid in Acetonitrile Gradient: % to 9 % B over utes Flow Rate:. ml/ Temperature: Ambient Detection: Sample:. Uracil. Pindolol. Chlorophenirae. Nortriptyline. -Methyl--Nitrobenzoic acid 6. -hydroxy,-methylbenzaldehyde 7. Hexaphenone 7 Waters XBridge µm C8 x.6 mm 8 6 Pressure: bar 7 6 APP ID Waters and XBridge are registered trademarks of Waters Corporation. Phenomenex is not affiliated with Waters Corporation. Comparative separations may not be representative of all applications.

14 WONDER Imagine No Suppression Ever have that moment of panic when polar analytes elute way too early in low or neutral ph mobile phases? It s time to put that worry to rest and marvel at the way you can use the enhanced ph stability of Kinetex EVO columns to dramatically improve the retention of polar, basic compounds. Low ph High ph 8.e 8.e 7.e 7.e 6.e 6.e Intensity, cps.e.e Intensity, cps.e.e.e.e.e.e APP ID 7.e.e APP ID 7 Column: Kinetex µm EVO C8 Dimensions: x. mm Part No.: D-6-Y Mobile Phase: A:. % Formic acid in Water B:. % Formic acid in Methanol Gradient: Time (). Flow Rate:.7 ml/ Temperature: Ambient Detection: MS % B 7 7 Sample:. -Hydroxycotinine. Nornicotine. Cotinine. Anabasine. Nicotine Column: Kinetex µm EVO C8 Dimensions: x. mm Part No.: D-6-Y Mobile Phase: A: mm Ammonium bicarbonate (unadjusted ph ~8.) B: Methanol Gradient: Time (). Flow Rate:.7 ml/ Temperature: Ambient Detection: MS % B 7 7 Sample:. -Hydroxycotinine. Nornicotine. Cotinine. Anabasine. Nicotine Phenomenex l WEB:

15 Core-Shell Technology WONDER Increased Sensitivity for LC/MS Applications Alongside LC/UV analyses, the high performance and low pressure of the Kinetex EVO μm make it a tremendous tool for LC/MS and LC/MS/MS. Increased polar basic retention provided by the Kinetex EVO allows for greater use of organic within the mobile phase, subsequently leading to improved ionization and increased sensitivity..e.8e.6e.e Intensity, cps.e.e 8.e 6.e.e.e APP ID 7 6 Mobile Phase: A:. % Formic acid in Water B:. % Formic acid in Methanol Gradient: Time () % B Column: Kinetex µm EVO C8 Dimensions: x. mm Part No.: B-6-AN Mobile Phase: A: mm Ammonium Bicarbonate (ph 8.) B: Methanol Gradient: Time () Flow Rate:. ml/ Temperature: Ambient Detection: MS/MS (AB SCIEX API ) Sample:. Sufentanil % B 8 8 8

16 DESIRE The Best C8 Columns For You With more C8 s on the market than any other phase, it s important to understand how the best ones can benefit you! Switch between the combination of the all-purpose Kinetex C8 and butyl side chain bonded XB-C8 to get small defined changes in retention and selectivity. Use the Kinetex EVO for enhanced peak shape of bases and extra alkaline ph stability. Kinetex µm EVO C8 Kinetex µm XB-C8 APP ID 79 APP ID Conditions for all columns: Column: Kinetex µm EVO C8 Kinetex µm XB-C8 Kinetex µm C8 Dimensions: x.6 mm Mobile Phase: A: mm Potassium phosphate (ph.) B: Acetonitrile Gradient: - % B in utes Flow Rate:. ml/ Temperature: C Detection: nm Sample: Nutraceutical Mix Kinetex µm C8 APP ID Phenomenex l WEB:

17 Core-Shell Technology DESIRE Built For Your Needs Two exceptional selectivities give you retention enhancement without performance loss. Use the multi-functional Kinetex Biphenyl or ph stable Kinetex EVO C8 to reach the desired solution for your method..8e.6e.e.e.e.8e.6e.e.e.e 8.e 6.e.e.e Kinetex µm C8 6 APP ID 7.8e.6e.e.e.e.8e.6e.e.e.e 8.e 6.e.e.e Keep same mobile phase Kinetex µm Biphenyl 6 APP ID 7.8e.6e.e.e.e.8e.6e.e.e.e 8.e 6.e.e.e Switch to high ph mobile phase Kinetex µm EVO C8 6 APP ID 7 Conditions for all columns: Column: Kinetex µm C8 Kinetex µm Biphenyl Kinetex µm EVO C8 Dimensions: x. mm Mobile Phase: A:. % Formic acid in Water B:. % Formic acid in Methanol Mobile Phase: A: mm Ammonium Bicarbonate (ph 8.) B: Methanol Gradient: Time () Flow Rate:. ml/ Temperature: Ambient % B Detection: MS/MS (AB SCIEX API ) Sample: Opiates Mix 7

18 ZEST Get Enthusiastic About Prep LC Reach new levels of purification with the ground-breaking combination of Kinetex EVO coreshell particles and AXIA preparative column technology. This technological combination provides genuine benefits including excellent loadability, high efficiency levels, and incredible ph stability. On top of all this, scaling and method optimization from analytical to prep is a breeze. Waters XBridge µm C8 x.6 mm Kinetex µm EVO C8 x.6 mm Impurity Not Resolved APP ID 7 6 Excellent Resolution APP ID Analytical to PREP Scalability Conditions for all columns: Column: Kinetex µm EVO C8 XBridge µm C8 Dimensions: x.6 mm x. mm (Kinetex AXIA Packed) Mobile Phase: A:. % TFA in Water B:. % TFA in Acetonitrile Gradient: % to 7 % B over utes Flow Rate:. ml/ ml/ (Kinetex AXIA) Temperature: Ambient Detection: Sample: Proprietary Pharmaceutical Sample Kinetex µm EVO C8 x. mm AXIA 6 8 APP ID 7 8 Waters and XBridge are registered trademarks of Waters Corporation. Phenomenex is not affiliated with Waters Corporation. Comparative separations may not be representative of all applications. Phenomenex l WEB:

19 Core-Shell Technology ZEST Got an Appetite For Better Results? Kinetex EVO will easily pave the way to enhanced purification and isolation levels with its incredible ph durability and core-shell performance gains. Get ready for a future of high yields and chromatographic improvements over traditional fully porous and hybrid materials. Kinetex µm EVO C8 Waters Xbridge µm C8 x. mm AXIA x 9 mm Prep OBD 7 Amazing Peak Shape Over All Sample Loads 7 mv 7 APP ID 768 mv 7 APP ID Conditions for all columns: Column: Kinetex µm EVO C8 Axia packed XBridge µm C8 Prep OBD Dimensions: x. mm (Kinetex) x 9 mm (XBridge) Mobile Phase: A:. % TFA in Water B:. % TFA in Acetonitrile Gradient: -9 % B in. Hold for. Re-equilibrate for. Flow Rate: ml/ Temperature: Ambient Detection: Sample:. Amitriptyline Sample Load: mg mg mg mg mg 8 mg Waters and XBridge are registered trademarks of Waters Corporation. Phenomenex is not affiliated with Waters Corporation. Comparative separations may not be representative of all applications. 9

20 Get Method Development Flexibility For Your Small Molecule Analysis Recommended Selectivities If You re Working With: Acids Bases Neutrals Aromatics Kinetex C8 Kinetex EVO C8 Kinetex C8 Kinetex Biphenyl Kinetex XB-C8 Kinetex XB-C8 Kinetex C8 Kinetex Phenyl-Hexyl Kinetex Phenyl-Hexyl Kinetex Biphenyl Kinetex Biphenyl Kinetex C8 Acids, Bases, and Neutrals Highly Polar Compounds High ph Kinetex C8 Kinetex EVO C8 Kinetex HILIC Kinetex EVO C8 Kinetex Biphenyl Kinetex C8 Kinetex EVO C8 Kinetex Biphenyl Upgrading Your Fully Porous Methods: Fully Porous µm or µm Fully Porous sub- µm Fully Porous Preparative LC µm Kinetex or Kinetex EVO Drop-in for easy performance improvements with no backpressure increase.6 µm Kinetex Dramatically improve results with efficiency/ peak capacity gains.6 µm Kinetex Get similar efficiencies at lower backpressure allowing for greater productivity gains.7 µm Kinetex Up to % greater efficiencies resulting in drop-in improvements. µm Kinetex Incredible efficiency gains on high end UHPLC systems µm Kinetex or Kinetex EVO Drop-in for easy performance improvement with no backpressure increase Phenomenex l WEB:

21 Choosing The Best Core-Shell Platform For You is Easy! Core-Shell Technology For Small Molecules µm.6 µm.6 µm.7 µm. µm UHPLC HPLC PREP LC Material Phase Best Use ph Stability Available Particle Size(s) Kinetex EVO C8 Robust reversed phase methods even in alkaline conditions with improved peak shape for polar basic compounds - µm Kinetex C8 XB-C8 C8 Biphenyl Phenyl-Hexyl HILIC All purpose phase that offers the hydrophobic retention and methylene selectivity chromatographers expect from a C8 column C8 phase with protective butyl side chains for improved peak shape for basic compounds under neutral and acidic conditions USP L7 phase that provides less hydrophobic and methylene selectivity than a C8 % aqueous stable and allows for excellent reversed phase retention and enhanced polar and aromatic selectivity Reversed phase chemistry that allows for greater retention and separation of aromatic hydrocarbons Unbonded silica phase for HILIC conditions to provide selectivity for polar compounds * µm.6 µm.7 µm. µm * µm.6 µm.7 µm * µm.6 µm.7 µm * µm.6 µm.7 µm * µm.6 µm.7 µm µm.6 µm.7 µm Phenomenex Application Specific Core-Shell Products Material Phase Best Use ph Stability Available Particle Size(s) For Peptides (, Da) Aeris PEPTIDE XB-C8 Excellent hydrophobicity and methylene selectivity for peptide and peptide mapping separations µm.6 µm.6 µm.7 µm For Proteins (, Da) Aeris WIDEPORE XB-C8 XB-C8 C Maximum hydrophobicity and high temp stability for hydrophilic and PEGylated proteins Medium hydrophobicity and high temp stability for moderately hydrophobic proteins and glycosylated proteins Lowest hydrophobicity for very large or very hydrophobic proteins µm µm µm For Synthetic Oligonucleotides (DNA/RNA) Clarity Rapid, high efficiency reversed phase LC/MS analysis for QC C8 Oligo-MS and characterization *ph stability under gradient conditions. ph stability is.- under isocratic conditions *.6 µm.7 µm

22 Ordering Information SecurityGuard μm Minibore Columns (mm) ULTRA Cartridges Phases x. x. x. x. /pk EVO C8 B-6-AN D-6-AN F-6-AN AJ-998 Biphenyl A-67-AN B-67-AN D-67-AN AJ-99 XB-C8 A-6-AN B-6-AN D-6-AN AJ-878 C8 A-6-AN B-6-AN D-6-AN F-6-AN AJ-878 C8 B-68-AN D-68-AN AJ-878 Phenyl-Hexyl B-6-AN D-6-AN AJ-8788 for. mm ID SecurityGuard μm MidBore Columns (mm) ULTRA Cartridges Phases x. x. x. /pk If you are not completely satisfied with Kinetex core-shell columns, send in your comparative data to a similar product within days and keep the column for FREE. EVO C8 B-6-Y D-6-Y F-6-Y AJ-997 Biphenyl B-67-Y D-67-Y F-67-Y AJ-98 XB-C8 B-6-Y D-6-Y F-6-Y AJ-877 C8 B-6-Y D-6-Y F-6-Y AJ-877 C8 B-68-Y D-68-Y AJ-8777 Phenyl-Hexyl B-6-Y D-6-Y AJ-878 for. mm ID SecurityGuard μm Analytical Columns (mm) ULTRA Cartridges Phases x.6 x.6 x.6 x.6 /pk EVO C8 B-6-E D-6-E F-6-E G-6-E AJ-996 Biphenyl B-67-E D-67-E F-67-E G-67-E AJ-97 XB-C8 B-6-E D-6-E F-6-E G-6-E AJ-8768 C8 B-6-E D-6-E F-6-E G-6-E AJ-8768 C8 B-68-E D-68-E F-68-E G-68-E AJ-877 Phenyl-Hexyl B-6-E D-6-E F-6-E G-6-E AJ-877 for.6 mm ID SecurityGuard μm Semi-Preparative Columns (mm) SemiPrep Cartridges*** Phases x x x /pk C8 F-6-N G-6-N AJ-978 Biphenyl F-67-N G-67-N AJ-98 for mm ID SecurityGuard μm Axia Packed Preparative Columns (mm) PREP Cartridges* Phases x. x. x. x. x. /ea EVO C8 B-6-P-AX D-6-P-AX F-6-P-AX G-6-P-AX AJ-9 /ea Biphenyl B-67-P-AX D-67-P-AX F-67-P-AX G-67-P-AX AJ-97 XB-C8 B-6-P-AX D-6-P-AX F-6-P-AX G-6-P-AX AJ-9 C8 B-6-P-AX D-6-P-AX F-6-P-AX G-6-P-AX AJ-9 C8 B-68-P-AX D-68-P-AX F-68-P-AX G-68-P-AX AJ-9 Phenyl-Hexyl B-6-P-AX D-6-P-AX F-6-P-AX G-6-P-AX AJ-97 HILIC D-66-P-AX F-66-P-AX G-66-P-AX AJ-977 for. mm ID SecurityGuard μm Axia Packed Preparative Columns (mm) PREP Cartridges** Phases x x x x x /ea Biphenyl F-67-U-AX AJ-97 XB-C8 B-6-U-AX D-6-U-AX F-6-U-AX G-6-U-AX AJ-9 C8 B-6-U-AX D-6-U-AX F-6-U-AX G-6-U-AX AJ-9 C8 B-68-U-AX D-68-U-AX F-68-U-AX G-68-U-AX AJ-97 Phenyl-Hexyl B-6-U-AX D-6-U-AX F-6-U-AX G-6-U-AX AJ-96 for mm ID Phenomenex l WEB: SecurityGuard ULTRA Cartridges require holder, Part No.: AJ-9 * PREP SecurityGuard Cartridges require holder, Part No.: AJ-8 ** PREP SecurityGuard Cartridges require holder, Part No.: AJ-877 *** SemiPrep SecurityGuard Cartridges require holder, Part No.: AJ-98

23 Ordering Information Core-Shell Technology SecurityGuard.6 μm Minibore Columns (mm) ULTRA Cartridges Phases x. x. 7 x. x. x. /pk Biphenyl A-6-AN B-6-AN D-6-AN F-6-AN AJ-99 XB-C8 A-96-AN B-96-AN C-96-AN D-96-AN F-96-AN AJ-878 C8 A-6-AN B-6-AN C-6-AN D-6-AN F-6-AN AJ-878 C8 A-97-AN B-97-AN C-97-AN D-97-AN F-97-AN AJ-878 HILIC A-6-AN B-6-AN C-6-AN D-6-AN F-6-AN AJ-8786 Phenyl-Hexyl A-9-AN B-9-AN C-9-AN D-9-AN F-9-AN AJ-8788 for. mm ID SecurityGuard.6 μm MidBore Columns (mm) ULTRA Cartridges Phases x. x. 7 x. x. x. /pk Biphenyl B-6-Y D-6-Y F-6-Y AJ-98 XB-C8 A-96-Y B-96-Y C-96-Y D-96-Y F-96-Y AJ-877 C8 A-6-Y B-6-Y C-6-Y D-6-Y F-6-Y AJ-877 C8 A-97-Y B-97-Y C-97-Y D-97-Y F-97-Y AJ-8777 HILIC A-6-Y F-6-Y AJ-8779 Phenyl-Hexyl B-9-Y D-9-Y F-9-Y AJ-878 for. mm ID SecurityGuard.6 μm Analytical Columns (mm) ULTRA Cartridges Phases x.6 x.6 7 x.6 x.6 x.6 /pk Biphenyl B-6-E D-6-E F-6-E AJ-97 XB-C8 B-96-E C-96-E D-96-E F-96-E AJ-8768 C8 A-6-E B-6-E C-6-E D-6-E F-6-E AJ-8768 C8 B-97-E C-97-E D-97-E F-97-E AJ-877 HILIC B-6-E C-6-E D-6-E F-6-E AJ-877 Phenyl-Hexyl B-9-E C-9-E D-9-E F-9-E AJ-877 for.6 mm ID SecurityGuard.7 μm Minibore Columns (mm) ULTRA Cartridges Phases x. x. x. x. /pk Biphenyl B-68-AN D-68-AN F-68-AN AJ-99 XB-C8 A-98-AN B-98-AN D-98-AN F-98-AN AJ-878 C8 A-7-AN B-7-AN D-7-AN F-7-AN AJ-878 C8 A-99-AN B-99-AN D-99-AN F-99-AN AJ-878 HILIC A-7-AN B-7-AN D-7-AN AJ-8786 Phenyl-Hexyl B--AN D--AN F--AN AJ-8788 for. mm ID SecurityGuard.7 μm MidBore Columns (mm) ULTRA Cartridges Phases x. x. x. /pk XB-C8 A-98-Y B-98-Y D-98-Y AJ-877 C8 B-7-Y D-7-Y AJ-877 C8 A-99-Y B-99-Y D-99-Y AJ-8777 HILIC B-7-Y AJ-8779 for. mm ID. μm Minibore Columns (mm) Phases x. x. C8 A--AN B--AN SecurityGuard ULTRA Cartridges require holder, Part No.: AJ-9 Terms and Conditions Subject to Phenomenex Standard Terms & Conditions, which may be viewed at Trademarks Phenomenex, Clarity, and Kinetex are registered trademarks of Phenomenex. Axia, Aeris, Oligo-MS, MidBore and SecurityGuard are trademarks of Phenomenex. Waters and XBridge are registered trademarks of Waters Corporation. Agilent and Poroshell are registered trademarks of Agilent Technologies, Inc. Ascentis and Supelco are registered trademarks of Sigma-Aldrich Co. ACE is a registered trademark and UltraCore is a trademark of Advanced Chromatography Technologies Limited. Disclaimer Phenomenex is not affiliated with Advanced Chromatography Technologies Limited, Agilent Technologies, Sigma-Aldrich Co., or Waters Corporation. Comparative separations may not be representative of all applications. SecurityGuard is patented by Phenomenex. U.S. Patent No. 6,6,6. CAUTION: this patent only applies to the analytical-sized guard cartridge holder, and does not apply to SemiPrep, PREP or ULTRA holders, or to any cartridges. Axia is patented by Phenomenex. U.S. Patent No. 7, 67, 8 Kinetex EVO is patented by Phenomenex. U.S. Patent Nos. 7,6,67 and 8,68,8 and foreign counterparts. The opinions stated herein are solely those of the speaker and not necessarily those of any company or organization. Phenomenex, Inc. All rights reserved.

24 Introducing Kinetex EVO! Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity Core-Shell Technology Australia t: f: auinfo@phenomenex.com Austria t: -9- f: -9- anfrage@phenomenex.com Belgium t: (French) t: 8666 (Dutch) f: + ()-879 beinfo@phenomenex.com Canada t: (8) -68 f: () info@phenomenex.com Denmark t: 8 88 f: nordicinfo@phenomenex.com Finland t: f: nordicinfo@phenomenex.com France t: 9 f: 9 franceinfo@phenomenex.com Germany t: f: anfrage@phenomenex.com India t: - f: - indiainfo@phenomenex.com Ireland t: 7 f: eireinfo@phenomenex.com Italy t: 67 f: 67 italiainfo@phenomenex.com Luxembourg t: + ()-87 f: + ()-879 nlinfo@phenomenex.com Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: -87 f: -879 nlinfo@phenomenex.com New Zealand t: f: nzinfo@phenomenex.com Norway t: 8 f: nordicinfo@phenomenex.com Puerto Rico t: (8) -HPLC f: () info@phenomenex.com Sweden t: f: nordicinfo@phenomenex.com United Kingdom t: 6-67 f: ukinfo@phenomenex.com United States t: () - f: () info@phenomenex.com All other countries: Corporate Office USA t: () - f: () info@phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR87_I

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology Core-Shell Technology Kinetex EVO C8 HPLC/UHPLC Core-Shell Columns Greater Polar Retention with % Aqueous Stability Robust Methods from ph - Improved Peak Shape for Bases NEW.7 µm NEW. µm µm Unconventionally

More information

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns. For Far Greater UHPLC Column Performance... You Must Have Kinetex Core-Shell UHPLC Columns www.phenomenex.com/kinetex The UHPLC Core-Shell Advantage Kinetex Core-Shell Technology produces increased efficiencies

More information

Core-Shell Technology for Proteins and Peptides

Core-Shell Technology for Proteins and Peptides Core-Shell Technology for Proteins and Peptides Better BioSeparations on HPLC and UHPLC Systems www.phenomenex.com/aeris Aeris Core-Shell Technology Core-Shell Particles Precision Engineered for Protein

More information

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology. Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology Jeff Layne, Phenomenex, Inc. Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 951 USA With virtually

More information

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1 APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there

More information

Preparative Chromatography Meets UHPLC

Preparative Chromatography Meets UHPLC Preparative Chromatography Meets UHPLC The Power of Kinetex Core-Shell Technology with the Performance of Piston Packed Prep Columns Ultra-High Efficiencies Ultra-Long Lifetimes NO Added Pressure Two Award

More information

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Michael McGinley, Deborah Jarrett, and Jeff Layne Phenomenex, Inc., 411 Madrid Avenue, Torrance, CA 91 USA Aeris WIDEPORE

More information

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market Better UHPLC Performance Starts NW.7 µm Core-Shell * Columns The IRST and NLY sub- µm core-shell columns on the market Phenomenex India Laxmi Cyber City, Ground loor, B Block, Survey no: Kondapur, Hyderabad

More information

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit Kinetex 5 µm Core-Shell Columns Deliver Significant Improvements in Chromatographic Efficiency and Resolution versus Traditional Fully Porous 5 µm Columns Philip J. Koerner and Jeff Layne Phenomenex, Inc.,

More information

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns Core-Shell Technology 11 HPLC Myths Uncovered & Why You Must Have Kinetex Core-Shell HPLC Columns 2.6 www.phenomenex.com/kinetex HPLC myths have been around since the early 19 s! From the one about the

More information

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you! Core-Shell Technology NEW Kinetex enyl Biph Biphenyl TM S TM Selectivity that a C8 just can t give you! S Bip he ylhenyl Bnip Remarkable Separation Power Rugged and Reliable % Aqueous Stable Kinetex Core-Shell

More information

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput ULTIMATE HPLC/UHPLC CMB Kinetex Luna mega Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput NEW MEGA Core-Shell Technology Luna mega Luna mega PS Kinetex. Kinetex Luna mega Cutting

More information

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance

More information

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm

More information

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1. APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,

More information

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced SIMPLIFIED IRAL SEPARATIS Lux ellulose- Guaranteed Alternative to IRALEL D- Exceptional Quality Sensibly Priced Lux ellulose- ellulose tris(3,5-dimethylphenylcarbamate) This dimethyl cellulose selector

More information

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns Core-Shell Technology NEW Kinetex Whoa! I can even separate structural isomers! TMS TMS HPLC/UHPLC Core-Shell Columns Reduce Method Development Time by Days Greater Reproducibility than other PPs Glorious

More information

Finally, a Solid Phase Extraction product for Drugs of Abuse

Finally, a Solid Phase Extraction product for Drugs of Abuse n io t c a r t x E e s a h P d li Finally, a So e s u b A f o s g u r D r fo product Imagine Only Needing 1 SPE Sorbent For All of Your Drugs of Abuse Extractions Extract over 11 drugs using the same sorbent

More information

APPLICATIONS TN Analytical Method

APPLICATIONS TN Analytical Method APPLICATIONS Simultaneous Determination of Antidepressants and Metabolites in Urine Using Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry (UHPLC-MS/MS) using a Kinetex Core-Shell

More information

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD Determination of Sugars in Animal Feed using HPLC-ELSD Laura Snow, Zeshan Aqeel, Allen Misa and Scott Krepich Phenomenex, Inc., Madrid Ave., Torrance, CA 9050 USA Laura Snow Scientist- Phenologix Outside

More information

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases T-1164 APPLICATIS Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases Marc Jacob, Liming Peng, Michael Klein, Tom eveland,

More information

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns Shuguang Li, Sky Countryman, and Erica Pike Phenomenex,

More information

Figure 1. Core-Shell Particle Technology

Figure 1. Core-Shell Particle Technology Purification of Chlorogenic cid from Green Coffee using Kinetex Core-Shell Technology in xia Preparative Formats Zeshan qeel Technical Magician Zeeshan loves to collect watches and the ack to the Future

More information

Labs Across the World Are Advancing Their Protein Precipitation

Labs Across the World Are Advancing Their Protein Precipitation Phospholipid Removal Solutions Labs Across the World Are Advancing Their Protein Precipitation Achieve Cleaner Samples Extend HPLC Column Lifetime Improve Analyte Sensitivity Reduce Mass Spec Maintenance

More information

Phospholipid Removal Solutions

Phospholipid Removal Solutions Remove Phospholipids Remove Protein No Method Development www.phenomenex.com/phree One Quick Method, Three Big Advantages 1 2 Remove Proteins that can clog HPLC columns Eliminate Phospholipids that cause

More information

METHAMPHETAMINE & AMPHETAMINE

METHAMPHETAMINE & AMPHETAMINE METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine Rapid and Accurate Chiral Separation Polysaccharide Chiral Chiral LC LC Columns and SFC PHEN-RUO-49 Revision: Lux 3 µm AMP Column High Efficiency LC/MS/MS

More information

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite T-1154 APPLICATIS Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS Matthew Trass, Shahana Huq, Seyed Sadjadi, Sky Countryman and Zdravko

More information

APPLICATIONS TN Materials and Methods

APPLICATIONS TN Materials and Methods APPLICATIONS A Simple, Fast, and Efficient HPLC Method for Sensitive, Accurate, and Reproducible Quantitation of Vitamin C in Human Plasma by Applying Impact Protein Precipitation Plate Technology with

More information

Protect Your Mass Spec

Protect Your Mass Spec Protect Your Mass Spec Sample Preparation Solutions for Biological Samples www.phenomenex.com/bioms Dirty Samples Could be Costing You Money and Sensitivity Biological samples contain a wide variety of

More information

PAIN PANEL. Research and Solutions

PAIN PANEL. Research and Solutions PAIN PANEL Research and Solutions Pain management drug use and abuse has increased significantly in recent years. The 21 National Survey on Drug Use & Health (NSDUH) reports that 17.3% of first-time drug

More information

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB: Exceed your Purification Goals Guaranteed The Axia Prep Column Advantage Extended column lifetime Reproducibility: column-to-column and batch-to-batch igher efficiency Improved peak shape Increased loadability

More information

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) APPLICATIONS A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) Ann Montross Technical Specialist Ann enjoys cooking/baking and roasting her

More information

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes Application Guide PAIN PANEL Screen 41 compounds in under 4 minutes Solutions for large compound screens and individual compound classes such as benzodiazepines, opiates, and more Achieve resolution of

More information

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex.6 µm Core-Shell Technology Column Philip J. Koerner, Matthew Trass, and Jeff Layne Phenomenex, Inc., Madrid Ave.,

More information

Prep Columns. and Bulk Media. and Bulk Media

Prep Columns. and Bulk Media. and Bulk Media Prep Columns and Bulk Media Axia Columns...346-355 Process Chromatography...356-36 Bulk Media...356-36 Columns, Scout and Preparative...359-36 Sepra Bulk Sorbents... 36 Prep Columns and Bulk Media 345-36

More information

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse Keep It Clean Solid Phase Extraction Solutions for Drugs of Abuse Analysis Neutral Drugs of Abuse Basic Drugs of Abuse Strata -X-Drug B: Basic Drugs of Abuse Working with basic drugs? Here are 3 reasons

More information

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction.

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction. Polymeric SPE Strata-X- Drug B Simplify Your Solid Phase Extraction QC Tested for Drugs of Abuse No Equilibration or Conditioning Required NEW! Drug B Plus for In-Well Hydrolysis www.phenomenex.com/strataxdrug

More information

APPLICATION TN Materials and Methods Reagents and Chemicals

APPLICATION TN Materials and Methods Reagents and Chemicals TN-8 APPLICATION Fast Analysis of Sucrose,, and Composition in Fruit Juices and Processed Beverages using Simplified HPLC Methodology Brian Rivera Product Manager In addition to chromatography, Brian also

More information

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable,

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology Kinetex. µm UHPLC Coumns The chosen core-she brand to drive UHPLC performance to the next eve Simpy Advantageous The band broadening (wide peaks) and engthy retention times of traditiona fuy porous products

More information

Hyper-fast & Super-rugged

Hyper-fast & Super-rugged Hyper-fast & Super-rugged UHPLC & HPLC columns FALL 2013 PRODUCT CATALOG Hyper-fast & Super-rugged UHPLC & HPLC columns he introduction of HALO columns, developed using innovative Fused-Core particle

More information

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky

More information

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs APPLICATION Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs Seyed Sadjadi, Shahana Huq, Sean Orlowicz, and Laura Snow Phenomenex, 4 Madrid Avenue, Torrance,

More information

Keep it Clean with Strata -X

Keep it Clean with Strata -X Simplified Solid Phase Extraction Solutions Neutral Compounds Acidic Compounds Basic Compounds Strong Acids (pk a < 2 Weak Acids (pk a 2-4 Neutral Compounds Weak Bases (pk a 8-10 Strong Bases (pk a > 10

More information

A New Era in SFC Column Technology

A New Era in SFC Column Technology B TM A ew Era in SFC Column Technology Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level

More information

Supported Liquid Extraction (SLE) For Food Applications

Supported Liquid Extraction (SLE) For Food Applications Supported Liquid Extraction (SLE) For Food Applications Novum Synthetic SLE Unique, Synthetic Sorbent that Provides Consistent, Reliable Results Strata DE Diatomaceous Earth SLE Cost-Effective, Guaranteed

More information

Effective Surface Area (m 2 /g) Pore Size (Å)

Effective Surface Area (m 2 /g) Pore Size (Å) n e w Ultra-High Performance on Any LC System Achieve sub- µm performance within HPLC backpressure limitations Substitute µm and µm columns for -x higher efficiency Obtain higher throughput without sacrificing

More information

Am I getting the very best value from my UHPLC analyses?

Am I getting the very best value from my UHPLC analyses? Am I getting the very best value from my UHPLC analyses? Stephen Luke LC Columns Product Manager 1 Primary reasons for UHPLC use Very fast Very high resolution Column 2.1 x 50 mm Column 2.1 x 150 mm Run

More information

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns APPLICATION Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns Sean Orlowicz Manager, PhenoLogix When not in the lab, Sean

More information

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC New Luna Omega 1.6 µm UHPLC Coumns The Fina Word in Fuy Porous UHPLC Enhanced with 2 Years of Technoogy, Innovation, and Experience One of the word s eading HPLC brands, now enhanced for incredibe UHPLC

More information

Agilent Technologies Prep LC Columns

Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies has always taken seriously its responsibility to ensure your success. That s why all our instruments and supplies

More information

World Renowned HPLC Media Reinvented for UHPLC!

World Renowned HPLC Media Reinvented for UHPLC! OMEGA World Renowned HPLC Media Reinvented for UHPLC! New. µm Staggering UHPLC Efficiencies and Performance Extreme Ruggedness and Mechanical Strength Perfect Complement to Kinetex Core-Shell Technology

More information

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE APPLICATINS Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE Sky Countryman, Shahana Huq, Terrell Mathews, et al. Phenomenex,

More information

ACE Excel UHPLC Columns

ACE Excel UHPLC Columns Excel UHPLC Columns info@ace-hplc.com Advanced Chromatography Technologies Ltd www.ace-hplc.com Australia & New Zealand contact: infor@winlab.com.au or call + 0 Outline Introduction Key Product Points

More information

Sepax Technologies, Inc.

Sepax Technologies, Inc. Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

ACE C18-AR Use the Power!

ACE C18-AR Use the Power! combines the retention and separation characteristics of a C18 phase with the extra selectivity of an integral phenyl functional group. The combination provides extra resolving power for a wide variety

More information

Analytical and Preparative SFC Columns

Analytical and Preparative SFC Columns Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...

More information

Vitamin Testing APPLICATIONS GUIDE

Vitamin Testing APPLICATIONS GUIDE Vitamin Testing APPLICATIONS GUIDE Vitamins play an essential role in human health and wellness. While essential, many vitamins cannot be synthesized within the body and must be obtained externally, most

More information

SIMPLIFIED CHIRAL SEPARATIONS. FIVE Complementary Chiral Phases. for Greater Selectivity. Resolve 92 %

SIMPLIFIED CHIRAL SEPARATIONS. FIVE Complementary Chiral Phases. for Greater Selectivity. Resolve 92 % SIMPLIFIED IRAL SEPARATIS FIVE omplementary hiral Phases for Greater Selectivity Resolve 9 % of all your Enantiomers using Screening Kits * FREE hiral Screening and Separation Services. *Based on screening

More information

2012 Waters Corporation 1

2012 Waters Corporation 1 An Introduction to Waters HPLC and ACQUITY UPLC Column Technologies for small molecule analysis Esa Lehtorinne Esa_Lehtorinne@waters.com Tel: +358-9-5659 5659 6288 Fax: +358-9-5659 5659 6282 Waters Finland

More information

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and

More information

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns Maximizing Efficiency Using Agilent InfinityLab Poroshell 12 Columns 1, Plates in Less Than Minutes Using Coupled Column Technology Application Note Food, Environmental, Chemical, Pharmaceutical Authors

More information

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis A New Standard of Confidence Calibration, Surrogate, & Internal Standards for Environmental Analysis Meets ISO/IEC 17025 & ISO Guide 34 Criteria Stay in Calibration Longer Lot-to-Lot Consistency ACCREDITED

More information

Ultimate Core Performance to Maximize Your Investment

Ultimate Core Performance to Maximize Your Investment Thermo Scientific Accucore HPL olumns Phase Overview Ultimate ore Performance to Maximize Your Investment Phase Overview Founded on state-of-the-art ore Enhanced Technology and utilizing vast experience

More information

The Raptor HILIC-Si Column

The Raptor HILIC-Si Column The Raptor HILIC-Si Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution

More information

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword   Pinnacle II Columns : 3μm or 5μm particles; 110Å pore size Silica at, for total control of quality and reproducibility. Excellent replacement for the original Hypersil material. Physical and chromatographic properties similar

More information

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. Fast High peak capacity Low back pressure PROTEIN PEPTIDE UHPLC COLUMNS Put these new, high-performance

More information

Fortis Method Development Options

Fortis Method Development Options Method Dev Fortis Method Development Options Choice of Stationary phase functionality Based on Ultra pure silica Reversed Phase (RP) and Normal Phase (NP) options Fortis Ho - Polar endcapped C8 - Increased

More information

Roc On with These Dependable LC Columns

Roc On with These Dependable LC Columns Roc LC s Conventional column built to be the cornerstone for your lab; pressure rated for any 400 bar system. Solid and reliable delivers the peak shape, reproducibility, ruggedness, and performance you

More information

Raptor HILIC-Si: Simplify the Switch to HILIC

Raptor HILIC-Si: Simplify the Switch to HILIC Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed

More information

Restek Ultra II HPLC Columns

Restek Ultra II HPLC Columns Restek Ultra II HPLC Columns THE Choice for All U(HPLC) Systems November 2009 1 www.chromtech.net.au, sales@chromtech.net.au, Tel: 03 9762 2034, Fax: 03 9761 1169 Topics for Today Introducing Restek Ultra

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Poor

More information

Choosing Preparative Columns

Choosing Preparative Columns Choosing Preparative Relationship between Column I.D., Sample Loading Volume and Flow Rate In preparative operations, column internal diameter sizes from 6.0 to 100 mm are widely used. When the analytical

More information

TN-0116 Scott Krepich

TN-0116 Scott Krepich TN-116 APPLICATIONS Analysis of Perfluorinated Compounds (PFCs) in Aqueous Matrices, Evaluating Various Online SPE Sorbents by LC-MS/MS Scott Krepich Senior Field Application Scientist Scott enjoys surfing

More information

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system A practical guide on how to use parameters to increase peak capacity Application Note Pharmaceutical and Chemical Author

More information

Comparison of a UPLC Method across Multiple UHPLC Systems

Comparison of a UPLC Method across Multiple UHPLC Systems Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid

More information

Lux. Five Distinct Polysaccharide Phases to Resolve 92 % of Your Enantiomers* Lux Cellulose-1. Lux Cellulose-3. Lux Cellulose-2.

Lux. Five Distinct Polysaccharide Phases to Resolve 92 % of Your Enantiomers* Lux Cellulose-1. Lux Cellulose-3. Lux Cellulose-2. Five Distinct Polysaccharide Phases to Resolve 9 % of Your Enantiomers* If Lux analytical columns ( 4.6 mm ID) do not provide at least an equivalent or better separation as compared to a competing column

More information

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior InertSustain Phenylhexyl A ew Second Choice Column to Change Chromatographic Behavior Providing Alternative Selectivity to C8 Phases InertSustain Phenylhexyl columns are bonded with phenylhexyl groups,

More information

Raptor HILIC-Si: Simplify the Switch to HILIC

Raptor HILIC-Si: Simplify the Switch to HILIC Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Poor retention

More information

CANNABIS TESTING ACCESSORIES

CANNABIS TESTING ACCESSORIES CANNABIS TESTING ACCESSORIES HPLC/GC/Sample Prep www.phenomenex.com/cannabis Popular Accessories for Cannabis Testing Cannabis Testing Accessories Sample Preparation Vials Sample Preparation Phenex Syringe

More information

Separations. Sweet Sugar. Are in Your Future. New. Luna Omega SUGAR LC Column OMEGA

Separations. Sweet Sugar. Are in Your Future. New.   Luna Omega SUGAR LC Column OMEGA OMEGA Sweet Sugar Separations Are in Your Future New Luna Omega SUGAR LC Column Improved carbohydrate retention and separation with novel HILIC selectivity Enhanced lifetime with highly robust and efficient

More information

GlycanPac AXR-1 Columns

GlycanPac AXR-1 Columns CHRMATGRAPHY GlycanPac AXR- Columns For High Resolution Glycan Analysis Product Specifications The Thermo Scientific GlycanPac AXR- columns are highperformance, silica-based HPLC columns for simultaneous

More information

C30 ISOMERS HAVE MET THEIR MATCH

C30 ISOMERS HAVE MET THEIR MATCH C30 ISOMERS HAVE MET THEIR MATCH INTRODUCING THE NEW! Built on proven Fused-Core particle technology, the is designed to deliver fast separations ideal for lipids and isomers compared to your C18. FEATURES

More information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA

More information

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS Introduction Drug analysis from whole blood is gaining popularity due to a more complete measurement

More information

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed! U.S. Patent No. 6, 162, 362 Column Protection for UHPLC, HPLC to PREP Protect HPLC columns and extend lifetime Virtually no change in chromatography Available in analytical, semi-prep, and preparative

More information

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated Fast, Rugged Raptor Columns with Time-Tested Selectivity Selectivity Accelerated Stationary Phase: Biphenyl CH 3 Si CH 3 O Pure Chromatography www.restek.com/raptor The Raptor Biphenyl Column With Raptor

More information

LC Columns with Liquid Separation Cell Technology

LC Columns with Liquid Separation Cell Technology Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,

More information

Core-Shell / Solid core Particles: A Practical Substitute to Sub-2 Micron Particles: An overview

Core-Shell / Solid core Particles: A Practical Substitute to Sub-2 Micron Particles: An overview Core-Shell / Solid core Particles: A Practical Substitute to Sub-2 Micron Particles: An overview ABSTRACT: S. M. Ramdharane 1, K. B. Vyas 2, K. S. Nimavat 3 * 1 Pacific Academy of Higher Education & Research

More information

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability ACE C8-AR A C8 bonded phase with unique selectivity Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and aromatic mixed mode interaction High efficiency µm, µm, µm and 0µm particles

More information

Impurity Profiling of Carbamazepine by HPLC/UV

Impurity Profiling of Carbamazepine by HPLC/UV Application Note: 52049 Impurity Profiling of Carbamazepine by HPLC/UV Terry Zhang, Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela Hypersil GOLD Carbamazepine Drug Analysis

More information

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns Converting a CHP Method for Insulin to Agilent Poroshell Columns Application Note Biopharm Author Rongjie Fu Agilent Technologies (Shanghai) Co., Ltd. 4 Ying Lun Road Shanghai 3 China Abstract A regulatory

More information

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 1 PFP Application Note Clinical Research Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd Abstract

More information

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific Thermo Scientific GlycanPac AXR-1 Column Product Manual P/N: April, 2014 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXR-1 Columns GlycanPac AXR-1, 1.9 µm, Analytical, 2.1 x 150 mm (P/N

More information

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases Clinical, Forensic & Toxicology Applications Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases By Shun-Hsin

More information

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column Diamond Analytics Technical Note: T131-1 Separation of Vitamin D and Vitamin D Metabolites on FLARE C1 MM (Mixed Mode) HPLC Column Introduction In this technical note, the versatility of the diamond-based

More information

Studies on Stationary Phase Selectivity for Solid-Core Particles

Studies on Stationary Phase Selectivity for Solid-Core Particles Studies on Stationary Phase Selectivity for Solid-Core Particles Richard A. enry, Wayne K. Way, Carmen T. Santasania, and David S. Bell Supelco, Div. of Sigma-Aldrich, Bellefonte, PA 6823 USA T4060 sigma-aldrich.com

More information