MFD Filters (MGF Series) 8.3. MFD Mini Regulators (MSR Series) 8.4. MFD General Purpose Regulators (MGR Series) 8.5

Size: px
Start display at page:

Download "MFD Filters (MGF Series) 8.3. MFD Mini Regulators (MSR Series) 8.4. MFD General Purpose Regulators (MGR Series) 8.5"

Transcription

1 ir Preparation Equipment MFD Filters (MGF Series) 8.3 MFD Mini Regulators (MSR Series) 8.4 MFD General Purpose Regulators (MGR Series) 8.5 MFD General Purpose Lubricators (MGL Series) 8.6 MFD Filter - Regulators (MGFR Series) 8.7 MFD FRL Combination (MGFC Series) 8.8 MFD FRL ccessories MFD Mounting ccessories 8.12 MFD ir Preparation Equipment List Prices Pneumatic Isolation Valves ir Preparation Equipment

2 ir Preparation Equipment From Filters FRL Combinations Mini Regulators Pressure Relief Valves General Purpose Regulators Soft Start Valves General Purpose Lubricators Distribution locks Filter Regulators Pneumatic Isolation Valves ir Preparation Equipment 8.2

3 MFD ir Preparation Equipment MGF Series Fluid Model MGF-6-S MGF-8-S Filters MGF-8 MGF-8-S MGF- MGF--S MGF-15 MGF-15-S MGF6- MGF6--S MGF6-25 MGF6-25-S Port Size 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 NPT 3/4 NPT 1 NPT Filtering Pressure Range Proof Pressure Temperature Range Drain owl Capacity ir µ standard (5µ optional) to 1 PSI 215 PSI to 16 F.34 FL OZ 1.35 FL OZ 2.7 FL OZ 7.8 FL OZ owl Material Polycarbonate owl Polycarbonate owl with Metal owl Guard Metal owl with Sight Glass ody Material Mounting luminum Individual racket or Modular Kit Drain lank: uto Drain S: Semi-uto Drain Includes Stamped Steel racket ir Preparation Equipment Manual Pneumatic Isolation Valves - PIV Series Dimensions (mm, except where noted) RCKET INCLUDED H G C F E J K Model C D E F G H J K MGF /8 NPT N/ MGF /4 NPT N/ MGF /4 NPT G 1/ MGF /8 NPT G 1/ MGF /2 NPT G 1/ MGF /4 NPT G 1/ MGF NPT G 1/ D Performance Data MGF Flow Characteristics MGF MGF MGF For Technical ssistance:

4 MFD ir Preparation Equipment MSR Series Mini Regulators Model MSR-6 MSR-8 Fluid ir Port Size 1/8 NPT 1/4 NPT Type Relieving regulators with push to lock adjustment knobs Pressure Range 7 to 1 PSI Proof Pressure 215 PSI Temperature Range to 16 F ody Material luminum Mounting Individual racket Includes Gauge / Stamped Steel racket / Nut / 2 Gauge Ports Dimensions (mm, except where noted) M x GUGE INCLUDED 2 RCKET INCLUDED WHEN DJUSTING KNO LOCKED 26 6: 1/8 8: 1/4 OTH SIDES (2) 1/8 NPT PRESSURE GUGE PORT Performance Data Flow Characteristics MSR Regulation Characteristics MSR Inlet Pressure (psi) Set Point 8.4

5 MFD ir Preparation Equipment MGR Series Fluid Model MGR-6 MGR-6-L MGR-8 MGR-8-L MGR-8 MGR-8-L MGR- MGR--L ir MGR-15 MGR6- MGR6-25 Port Size 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 NPT 3/4 NPT 1 NPT Type Pressure Range Proof Pressure Temperature Range ody Material Mounting Includes Dimensions (mm, except where noted) RCKET INCLUDED C D H J General Purpose Regulators E F G L M Relieving regulators with push to lock adjustment knobs lank: 7-1 PSI 215 PSI -16 F luminum L: 7-6 PSI Individual racket or Modular Kit Gauge / racket / Nut / 2 Gauge Ports Model C D E F G H J K L M MGR-6 32 M x 1.5 1/8 NPT MGR-8 32 M x 1.5 1/4 NPT MGR M x 1.5 1/4 NPT MGR M x 1.5 3/8 NPT MGR-15 M55 x 2. 1/2 NPT MGR M68 x 1.5 3/4 NPT MGR M68 x NPT ir Preparation Equipment Manual Pneumatic Isolation Valves - PIV Series K Performance Data Flow Characteristics Regulation Characteristics 9 MGR 9 MGR 32 MGR 32 MGR Set Point 29 Set Point Inlet Pressure (psi) Inlet Pressure (psi) 9 MGR 9 MGR6 32 MGR 32 MGR Set Point 29 Set Point Inlet Pressure (psi) Inlet Pressure (psi) 8.5 For Technical ssistance:

6 MFD ir Preparation Equipment MGL Series Fluid Model MGL-6 MGL-8 MGL-8 MGL- MGL-15 MGL6- MGL6-25 Port Size 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 NPT 3/4 NPT 1 NPT Pressure Range Proof Pressure Temperature Range ir 7-1 PSI 215 PSI -16 F Oil owl Capacity.85 FL OZ 2.5 FL OZ 5.4 FL OZ 12.8 FL OZ owl Material ody Material Recommended Lubricant Mounting Includes General Purpose Lubricators Polycarbonate owl Polycarbonate owl with Metal owl Guard luminum Non-Detergent SE, ISO VG32, or equivalent Individual racket or Modular Kit Stamped Steel racket Metal owl with Sight Glass Dimensions (mm, except where noted) RCKET INCLUDED E D Model C D E F G H J K F J MGL-6 1/8 NPT MGL-8 1/4 NPT MGL /4 NPT H K MGL- 41 3/8 NPT MGL-15 1/2 NPT MGL6-7 3/4 NPT MGL NPT C G Performance Data Flow Characteristics MGL MGL MGL MGL

7 MFD ir Preparation Equipment MGFR Series Fluid Model MGFR-6-S MGFR-8-S MGFR-8 MGFR-8-S MGFR- MGFR--S MGFR-15 MGFR-15-S MGFR6- MGFR6--S MGFR6-25 MGFR6-25-S Port Size 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 NPT 3/4 NPT 1 NPT Type Filtering Pressure Range Proof Pressure Temperature Range Drain owl Capacity ir Relieving regulators with push to lock adjustment knobs µ standard (5µ optional) to 1 PSI 215 PSI to 16 F.34 FL OZ 1.35 FL OZ 2.7 FL OZ 7.8 FL OZ owl Material Polycarbonate owl Polycarbonate owl with Metal owl Guard Metal owl with Sight Glass ody Material Mounting luminum Individual racket or Modular Kit Drain lank: uto Drain S: Semi-uto Drain Includes Filter - Regulators Stamped Steel racket / Nut ir Preparation Equipment Manual Pneumatic Isolation Valves - PIV Series Dimensions (mm, except where noted) C J K P F G H Model C D E F G H J K L M N P MGFR-6 32 M x 1.5 1/8 NPT N/ MGFR-8 32 M x 1.5 1/4 NPT N/ RCKET INCLUDED M MGFR M x 1.5 1/4 NPT G 1/ D L N MGFR M x 1.5 3/8 NPT G 1/ MGFR-15 M55 x 2. 1/2 NPT G 1/ MGFR M68 x 1.5 3/4 NPT G 1/ MGFR M68 x NPT G 1/ E Performance Data MGFR Flow Characteristics MGFR Regulation Characteristics MGFR MGFR 32 Set Point Inlet Pressure (psi) 32 Set Point Inlet Pressure (psi) MGFR MGFR MGFR 32 Set Point Inlet Pressure (psi) MGFR6 32 Set Point Inlet Pressure (psi) 8.7 For Technical ssistance:

8 MFD ir Preparation Equipment MGFC Series Fluid Model MGFC-6-S MGFC-8-S MGFC-8 MGFC- MGFC-15 Port size 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 NPT Type Filtering Pressure Range Proof Pressure Temperature Range ir Relieving regulators with push to lock adjustment knobs µ standard (5µ optional) to 1 PSI 215 PSI to 16 F Drain owl Capacity.34 FL OZ 1.35 FL OZ 2.7 FL OZ Oil owl Capacity.85 FL OZ 2.5 FL OZ 5.4 FL OZ owl Material Polycarbonate bowl Polycarbonate owl with Metal owl Guard ody Material Mounting Recommended Lubricant luminum T-racket Non-Detergent SE, ISO VG32, or equivalent Drain Semi-auto uto Includes FRL Combination T-racket / Nut Dimensions (mm, except where noted) T SHPE RCKET INCLUDED F G J K Model C D E F G H J K L MGFC-6-S 62 1/8 NPT N/ M x C D H L MGFC-8-S 62 1/4 NPT N/ M x MGFC /4 NPT G 1/8 M x MGFC /8 NPT G 1/8 M x MGFC /2 NPT G 1/4 M55 x E Performance Data MGFC MGFC Flow Characteristics MGFC Regulation Characteristics MGFC Set Point 26 1 Inlet Pressure (psi) MGFC 32 Set Point Inlet Pressure (psi) MGFC Set Point 26 1 Inlet Pressure (psi) 8.8

9 MFD ir Preparation Equipment MGZ Series Pressure Relief Valve P R Fluid Model MGZ-6-T MGZ-8-T MGZ-8-T MGZ--T MGZ-15-T Port Size 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 NPT cting Type Valve Type Pressure Range Proof Pressure Temperature Range ody Material Operating ngle Includes FRL ccessories ir Manual 3 ports - 2 position to 1 PSI 215 PSI to 16 F luminum 9 (Twist) T-racket and Stamped Steel racket and Lock ir Preparation Equipment Manual Pneumatic Isolation Valves - PIV Series Dimensions (mm, except where noted) M F C G RCKET INCLUDED T-racket Included H J L K 2 - D E N Model C D E F G H J K L M N MGZ-6-T /8 NPT /4 NPT MGZ-8-T /4 NPT /4 NPT MGZ-8-T /4 NPT /8 NPT MGZ--T /8 NPT /8 NPT MGZ-15-T /2 NPT /2 NPT 8.9 For Technical ssistance:

10 MFD ir Preparation Equipment MGV Series Soft Start-up Valve FRL ccessories Model MGV-6-T-24VDC MGV-8-T-24VDC MGV-8-T-24VDC MGV--T-24VDC MGV-6-T-1VC MGV-8-T-1VC MGV-8-T-1VC MGV--T-1VC MGV-15-T-24VDC MGV-15-T-1VC Fluid ir Port Size 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 NPT Exhaust Port Size 1/4 NPT 3/8 NPT 1/2 NPT cting Type Solenoid Operated, 3/2 Soft-Start Pressure Range 35 to 1 PSI Proof Pressure 215 PSI Temperature Range to 16 F Power Connection DIN P Voltage 1 VC or 24 VDC Voltage Range -15%~+% R Insulation Power Consumption Class 1 VC: 3.5V / 24 VDC: 2.5W Includes T-racket and Stamped Steel racket Dimensions (mm, except where noted) J K RCKET INCLUDED H G E C (2) T-racket Included D F M L Model C D E F G H J K L M MGV-6 1/8 NPT /4 NPT MGV-8 1/4 NPT /4 NPT MGV-8 1/4 NPT /8 NPT MGV- 3/8 NPT /8 NPT MGV-15 1/2 NPT /2 NPT 8.

11 MFD ir Preparation Equipment MG series ir Distribution lock Dimensions (mm, except where noted) FRL ccessories Model MG214-6-T MG214-8-T MG314-8-T MG314--T MG T Fluid ir Port Size 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 NPT # of uxiliary Ports 2 Pressure Range to 1 PSI Proof Pressure 215 PSI Temperature Range to 16 F Includes T-racket ir Preparation Equipment Manual Pneumatic Isolation Valves - PIV Series (4) Model C D MG214-6-T 1/8 NPT MG214-8-T 1/4 NPT MG314-8-T 1/4 NPT MG314--T 3/8 NPT MG T 1/2 NPT C D T-racket Included 8.11 For Technical ssistance:

12 MFD ir Preparation Equipment Mounting ccessories T racket Dimensions (mm, except where noted) J E F Model C D E F G H J MG1-P MG1-P MG1-P MG61-P C H G D L racket Model C D E F G H J E J MG2-P MG2-P F MG2-P C D G H MG62-P U racket Model C D E D MG3-P MG3-P C E MG3-P MG63-P Filter Elements Model Description MGF-4-1 Series - Micron Element Filter ronze MGF-4-2 Series - 5 Micron Element Filter Plastic MGF-4-1 Series - Micron Element Filter ronze MGF-4-2 Series - 5 Micron Element Filter Plastic MGF-4-1 Series - Micron Element Filter ronze MGF-4-2 Series - 5 Micron Element Filter Plastic MGF Series - Micron Element Filter ronze MGF Series - 5 Micron Element Filter ronze 8.12

13 MFD ir Preparation Equipment List Prices Filters Model Number Description Nominal List Price MGF-6-S Filter, 1/8 NPT, Semi-uto Drain 18- $14.15 MGF-8-S Filter, 1/4 NPT, Semi-uto Drain MGF-8 Filter, 1/4 NPT, uto Drain MGF-8-S Filter, 1/4 NPT, Semi-uto Drain MGF- Filter, 3/8 NPT, uto Drain MGF--S Filter, 3/8 NPT, Semi-uto Drain MGF-15 Filter, 1/2 NPT, uto Drain MGF-15-S Filter, 1/2 NPT, Semi-uto Drain MGF6- Filter, 3/4 NPT, uto Drain MGF6--S Filter, 3/4 NPT, Semi-uto Drain MGF6-25 Filter, 1 NPT, uto Drain MGF6-25-S Filter, 1 NPT, Semi-uto Drain Regulators ir Preparation Equipment Manual Pneumatic Isolation Valves - PIV Series Model Number Description Nominal List Price MGR-6 Regulator, 1/8 NPT, 1 psi Gauge, racket 18- $22.5 MGR-6-L Regulator, 1/8 NPT, 6 psi Gauge, racket MGR-8 Regulator, 1/4 NPT, 1 psi Gauge, racket MGR-8-L Regulator, 1/4 NPT, 6 psi Gauge, racket MGR-8 Regulator, 1/4 NPT, 1 psi Gauge, racket MGR-8-L Regulator, 1/4 NPT, 6 psi Gauge, racket MGR- Regulator, 3/8 NPT, 1 psi Gauge, racket MGR--L Regulator, 3/8 NPT, 6 psi Gauge, racket MGR-15 Regulator, 1/2 NPT, 1 psi Gauge, racket MGR6- Regulator, 3/4 NPT, 1 psi Gauge, racket MGR6-25 Regulator, 1 NPT, 1 psi Gauge, racket Lubricators Model Number Description Nominal List Price MGL-6 Lubricator, 1/8 NPT, racket 18- $12. MGL-8 Lubricator, 1/4 NPT, racket MGL-8 Lubricator, 1/4 NPT, racket MGL- Lubricator, 3/8 NPT, racket MGL-15 Lubricator, 1/2 NPT, racket MGL6- Lubricator, 3/4 NPT, racket MGL6-25 Lubricator, 1 NPT, racket ll product is sold F.O.. shipping point. Prices are subject to change without notice For Technical ssistance:

14 MFD ir Preparation Equipment List Prices Filter-Regulator Combination Units Model Description Nominal List Price MGFR-6-S Filter/Regulator, 1/8 NPT, Semi-uto Drain 18- $25.19 MFR-8-S Filter/Regulator, 1/4 NPT, Semi-uto Drain MGFR-8 Filter/Regulator, 1/4 NPT, uto Drain MGFR-8-S Filter/Regulator, 1/4 NPT, Semi-uto Drain MGFR- Filter/Regulator, 3/8 NPT, uto Drain MGFR--S Filter/Regulator, 3/8 NPT, Semi-uto Drain MGFR-15 Filter/Regulator, 1/2 NPT, uto Drain MGFR-15-S Filter/Regulator, 1/2 NPT, Semi-uto Drain MGFR6- Filter/Regulator, 3/4 NPT, uto Drain MGFR6--S Filter/Regulator, 3/4 NPT, Semi-uto Drain MGFR6-25 Filter/Regulator, 1 NPT, uto Drain MGFR6-25-S Filter/Regulator, 1 NPT, Semi-uto Drain Filter-Regulator Combo + Lubricator Model Number Description Nominal List Price MGFC-6 Filter/Regulator/Lube, 1/8 NPT, Semi-uto Drain 18- $. MGFC-8 Filter/Regulator/Lube, 1/4 NPT, Semi-uto Drain 18-. MGFC-8 Filter/Regulator/Lube, 1/4 NPT, Semi-uto Drain MGFC- Filter/Regulator/Lube, 3/8 NPT, uto Drain MGFC-15 Filter/Regulator/Lube, 1/2 NPT, uto Drain Solenoid Operated Soft-Start Valves Model Number Description Nominal List Price MGV-6-T-1VC Soft Start Valve, 1/8IN NPT, racket, 1VC 18- $57.78 MGV-6-T-24VDC Soft Start Valve, 1/8IN NPT, racket, 24VDC MGV-8-T-1VC Soft Start Valve, 1/4IN NPT, racket, 1VC MGV-8-T-24VDC Soft Start Valve, 1/4IN NPT, racket, 24VDC MGV-8-T-1VC Soft Start Valve, 1/4IN NPT, racket, 1VC MGV-8-T-24VDC Soft Start Valve, 1/4IN NPT, racket, 24VDC MGV--T-1VC Soft Start Valve, 3/8IN NPT, racket, 1VC MGV--T-24VDC Soft Start Valve, 3/8IN NPT, racket, 24VDC MGV-15-T-1VC Soft Start Valve, 1/2IN NPT, racket, 1VC MGV-15-T-24VDC Soft Start Valve, 1/2IN NPT, racket, 24VDC Manually Operated Shut-Off / Relief Valves Model Number Description Nominal List Price MGZ-6-T Pressure Relief Valve, 1/8IN NPT, Stamped racket 18- $22.6 MGZ-8-T Pressure Relief Valve, 1/4IN NPT, Stamped racket MGZ-8-T Pressure Relief Valve, 1/4IN NPT, Stamped racket MGZ--T Pressure Relief Valve, 3/8IN NPT, Stamped racket MGZ-15-T Pressure Relief Valve, 1/2IN NPT, Stamped racket ll product is sold F.O.. shipping point. Prices are subject to change without notice. 8.14

15 MFD ir Preparation Equipment List Prices uxiliary ir Porting locks Model Number Description List Price MG214-6-T ir Distribution lock, 1/8IN NPT with T racket $.49 MG214-8-T ir Distribution lock, 1/4IN NPT with T racket.49 MG314-8-T ir Distribution lock, 1/4IN NPT with T racket MG314--T ir Distribution lock, 3/8IN NPT, racket MG T ir Distribution lock, 1/2IN NPT, racket ir Preparation Equipment Modular Connector rackets Model Number Description List Price MG1-P1 Series T racket $4.75 MG2-P1 Series L racket 4. MG3-P1 Series U racket 4. MG1-P1 Series T racket 8. MG2-P1 Series L racket 6.9 MG3-P1 Series U racket 6.9 MG1-P1 Series T racket 8.75 MG2-P1 Series L racket 8.5 MG3-P1 Series U racket 8.5 MG61-P1 6 Series T racket.75 MG62-P1 6 Series L racket 9.25 MG63-P1 6 Series U racket 9.25 Manual Pneumatic Isolation Valves - PIV Series Replacement Filter Elements Model Number Description List Price MGF-4-1 Series, Micron Element $1. MGF-4-2 Series, 5 Micron Element 1. MGF-4-1 Series, Micron Element 2. MGF-4-2 Series, 5 Micron Element 2. MGF-4-1 Series, Micron Element 3.75 MGF-4-2 Series, 5 Micron Element 3.75 MGF Series, Micron Element 12. MGF Series, 5 Micron Element 12. For 5 micron filter element, add -W to model number and $3. LIST ll product is sold F.O.. shipping point. Prices are subject to change without notice For Technical ssistance:

16 imba Manual Pneumatic Isolation Valves - PIV Series Pneumatic Isolation Valves are typically the first valve following the FRL components in the line supplying compressed air to pneumatic equipment. FRL PIV Valve Operating Valve Pneumatic System Pneumatic Isolation Valves are the critical component in any safety lockout, tagout system. vailable sizes range from 1/4" inlet/outlet ports with 3/8" exhaust ports up to 1-1/2" inlet/outlet ports with 2" exhaust ports. vailable accessories include air mufflers, pressure switches, and air pressure visual indicators, and connecting hex nipples. List Prices Valves Part Number Inlet/Outlet Port Size Exhaust Port Size Note: The part numbers have been configured to provide information on applicable FRL series and port sizes. There is some overlap in the applicable FRL series. In/Out For example: PIV (Pneumatic Isolation Valve) - 6 (6 series FRL) - (Inlet/Outlet Port Size) - 75 (Exhaust Port Size) Cv Exhaust List Price PIV--25/38 1/4 NPT 3/8 NPT $79.35 PIV--38/38 3/8 NPT 3/8 NPT PIV--38/75 3/8 NPT 3/4 NPT PIV-6-/75 1/2 NPT 3/4 NPT PIV-6-75/75 3/4 NPT 3/4 NPT PIV-6-75/125 3/4 NPT 1-1/4 NPT PIV-7-/125 1 NPT 1-1/4 NPT PIV-7-125/ /4 NPT 1-1/4 NPT PIV-7-1/ 1-1/2 NPT 2 NPT Referenced Standards: ll standards are subject to revision. Parties are encouraged to investigate and apply the most recent editions of the standards indicated below. OSH 29 CFR ISO 14118: CS Z142-2 EN 37 CS Z46-5 NSI/SSE Z ISO NSI/PMMI ll product is sold F.O.. shipping point. Prices are subject to change without notice. 8.16

17 imba Manual Pneumatic Isolation Valves - PIV Series ccessories Part Number Description Port Size verage Cv List Price PIV-SIL-13 ir Muffler 1/8 NPT 2. $13.8 PIV-SIL-25 ir Muffler 1/4 NPT PIV-SIL-38 ir Muffler 3/8 NPT PIV-SIL-38-HF ir Muffler (High Flow) 3/8 NPT PIV-SIL- ir Muffler 1/2 NPT PIV-SIL-75 ir Muffler 3/4 NPT PIV-SIL-75-HF ir Muffler (High Flow) 3/4 NPT PIV-SIL- ir Muffler 1 NPT PIV-SIL-125 ir Muffler 1-1/4 NPT *PIV-SIL- ir Muffler 2 NPT CK-1/8 Hex Nipple 1/8 NPT N/ 3.45 CK-1/4 Hex Nipple 1/4 NPT N/ 4. CK-3/8 Hex Nipple 3/8 NPT N/ 4. CK6-1/2 Hex Nipple 1/2 NPT N/ 5.75 CK6-3/4 Hex Nipple 3/4 NPT N/ 9. CK7-1 Hex Nipple 1 NPT N/ 14.7 CK7-1-1/4 Hex Nipple 1-1/4 NPT N/ CK7-1-1/2 Hex Nipple 1-1/2 NPT N/ 53. ir Preparation Equipment Manual Pneumatic Isolation Valves - PIV Series Caution Note: Mufflers only rated to 1 psi. *Note: This size contains female threads. ll other sizes are male threaded. Dimensions PIV Valves Part Number In-Out Port Size ll dimensions are inches. Exhaust Port Size C D E F G H I J K PIV--25/38 1/4 3/ PIV--38/38 3/8 3/ ll product is sold F.O.. shipping point. Prices are subject to change without notice For Technical ssistance:

18 imba Manual Pneumatic Isolation Valves - PIV Series Dimensions PIV Valves PIV-7-1/ Only E H G PORT 2 (OUTLET) PORT 1 (INLET) PORT 2 (OUTLET) PORT 1 (INLET) F F 2X I THRU D 2X I THRU PORT 3 D (EXHUST) PORT 3 (EXHUST) C H G C Part Number In-Out Port Size Exhaust Port Size (open) (open) C D E F G H I PIV--38/75 3/8 3/ PIV-6-/75 1/2 3/ PIV-6-75/75 3/4 3/ PIV-6-75/125 3/4 1-1/ PIV-7-/ / PIV-7-125/ /4 1-1/ PIV-7-1/ 1-1/ ll dimensions are inches. ir Mufflers Part Number Port Size PIV-SIL-13 1/ PIV-SIL-25 1/ PIV-SIL-38 3/ PIV-SIL-38-HF 3/ PIV-SIL- 1/ PIV-SIL-75 3/ PIV-SIL-75-HF 3/ PIV-SIL PIV-SIL / *PIV-SIL ll dimensions are inches. * Note: The PIV-SIL- contains female threads. ll other sizes are male threaded. Hex Nipples Part Number Thread Size Material CK-1/8 1/8 NPT 1.6 7/16" lack Oxide Steel CK-1/4 1/4 NPT 1. 5/8" lack Oxide Steel CK-3/8 3/8 NPT /4" Zinc Plated Steel CK6-1/2 1/2 NPT /8" Zinc Plated Steel CK6-3/4 3/4 NPT /8" Zinc Plated Steel CK7-1 1 NPT /8" Zinc Plated Steel CK7-1-1/4 1-1/4 NPT /4" Zinc Plated Steel CK7-1-1/2 1-1/2 NPT " Zinc Plated Steel 8.18

19 imba Manual Pneumatic Isolation Valves - PIV Series Pneumatic Energy Release Verification Options Visual Pop-Up Indicator or Pressure Switch (electrical) May be installed on all PIV valves with pressure sensing port Provides a means to verify the release of downstream pressure to next obstruction. Verification Option Model Number Inlet Port Size* List Price Pop-Up Indicator PIV-POI 1/8 $.65 Pressure Switch PIV-PS 1/ * NPT port threads. ir Preparation Equipment Pop-Up Indicator Pressure Switch Manual Pneumatic Isolation Valves - PIV Series Pressure Switch Specifications Parameters Maximum Operating Pressure Set Point Tolerance Diaphragm Material Proof Pressure Specifications 6 psig (41 bar) ±1 psi or 5% (.7 bar) una N Differential 8-16% Current Rating Media Connection (2) Circuit Form (C) Electrical Connection (HR) 18 psi (124 bar) 2 VC VDC (Resistive) 1/8" NPT Male DT (Single Pole - Double Throw) DIN436 Wiring Diagram PIV Sensing Port PIV Sensing Port - imba Pneumatic Isolation Valves are provided with 1/8 NPT sensing ports, enabling installation of a pressure sensing device such as the Pop-Up Indicator or Pressure Switch shown above. Standards suggest that machine design should include a method for verifying the release of energy after lockout. The imba Pop-Up Indicator is constructed for the industrial environment with a brass body and 1/8" NPT connection. It offers 36 visibility and a redundant verification feature. y pushing on the red plunger, the operator can feel the presence of pressure and verify that the indicator is performing its sensing function. The imba Pressure Switch offers an electronic pressure sensing option that can be integrated into a safety monitoring system, which confirms energy isolation throughout the circuit. ll product is sold F.O.. shipping point. Prices are subject to change without notice For Technical ssistance:

20 imba Manual Pneumatic Isolation Valves - PIV Series How it Works 12 2 Manual PIV valve shown in the closed position. The valve can only be locked in the closed position. 3 1 Push/pull operation - Push the handle inward to exhaust downstream air (lockable in this position). Pull the handle outward to supply air downstream. Following any FRL components, an energy isolation valve is usually the first valve in the line supplying compressed air to equipment. The energy isolation valve should provide a quick means of shutting off the supply of air and exhausting the downstream lines. The imba PIV valve has a large red operating handle for high visibility. When the handle is pulled out, there is full line pressure. short, full inward push of the handle closes off the flow of air, and quickly exhausts the pressure in the downstream line. This action is swift and doesn t require a difficult, slow, or confusing twisting action. PIV- Series Valve Operation VLVE CLOSED When the red handle is pushed inward, the flow of supply air is blocked and downstream air is exhausted via the exhaust port. While servicing or maintaining machinery, the PIV valve should be padlocked in this position to prevent the handle from being pulled outward inadvertently where potential for human injury exists. 2 (out) 1 (in) 3 (exhaust) VLVE OPEN When the red handle is pulled outward supply air flows freely from inlet to outlet and flow to exhaust is blocked. detent keeps the handle in the open position. 2 (out) 1 (in) 3 (exhaust) STNDRD SPECIFICTIONS: mbient/media Temperature: to 175 F (4 to 8 C). Flow Media: Filtered air; 5 micron recommended. Inlet Pressure: 15 to 145 psig (1 to bar). Port Threads: NPT standard. Lock Hole Diameter:.27 inch (7.6 mm). Length of Hole:.43 inch (.92 mm). NOTE: Per specifications and regulations, these products are defined as energy isolation devices, NOT S EMERGENCY STOP DEVICES. 8.

21 imba Manual Pneumatic Isolation Valves - PIV Series PIV-6 Series VLVE CLOSED With a short push of the red handle inward, the flow of supply air is blocked and downstream air is exhausted via the exhaust port at the bottom of the valve. The PIV valve should be padlocked in this position to prevent the handle from being pulled outward inadvertently where potential for human injury exists or while servicing machinery. 2 (out) Valve Operation 3 (exhaust) 1 (in) STNDRD SPECIFICTIONS: mbient/media Temperature: o to 175 o F (4 o to 8 o C). Flow Media: Filtered air; 5 micron filter recommended. Inlet Pressure: 15 to psig (1 to bar). VLVE OPEN When the red handle is pulled out, supply air flows freely from inlet to outlet and flow to exhaust is blocked. detent keeps the handle in the open position. The handle is not designed to be locked in this position, thereby providing for ready shut-off when necessary. 2 (out) 3 (exhaust) 1 (in) Port Threads: NPT standard. NOTE: Per specifications and regulations, these products are defined as energy isolation devices, NOT S EMER- GENCY STOP DEVICES. ir Preparation Equipment Manual Pneumatic Isolation Valves - PIV Series PIV-7 Series VLVE CLOSED With a short push of the red handle inward, the flow of supply air is blocked and downstream air is exhausted via the exhaust port while servicing or maintaining machinery. Padlock the PIV valve in this position to prevent the handle from being pulled outward inadvertently to avoid potential for human injury while servicing machinery. VLVE OPEN When the red handle is pulled out, supply air flows freely from inlet to outlet and flow to exhaust is blocked. detent keeps the handle in the open position. The handle is not designed to be locked in this position, thereby providing for ready shut-off when necessary. STNDRD SPECIFICTIONS: mbient/media Temperature: to 175 F (4 to 8 C). Flow Media: Filtered air; 5 micron recommended. Inlet Pressure: 15 to psig (1 to bar). Port Threads: NPT standard. Lock Hole Diameter:.38 inch (9.6 mm). Length of Hole:.75 inch (19.1 mm). NOTE: Per specifications and regulations, these products are defined as energy isolation devices, NOT S EMERGENCY STOP DEVICES For Technical ssistance:

22 imba Manual Pneumatic Isolation Valves - PIV Series Referenced Standards: ll standards are subject to revision. Parties are encouraged to investigate and apply the most recent editions of the standards indicated below. OSH 29 CFR ISO 14118: CS Z142-2 EN 37 CS Z46-5 NSI/SSE Z ISO NSI/PMMI What does this regulation cover? In general terms, the rule requires that energy sources (pneumatic, electric, hydraulic, etc.) be shut off or disconnected while equipment is being serviced. Furthermore, the disconnected valve or switch must be locked to prevent reactivation while anyone is working on the equipment. In the case of air-operated equipment, a lockout valve must be used to cut off the air supply to the equipment and exhaust any stored or residual downstream air. (OSH Regulation 29 CFR lists a number of requirements for the control of hazardous energy sources.) In addition, imba PIV products assist manufacturers in complying with European regulation EN 37 (Safety of Machinery). For complete information, please read the entire regulations. Does this regulation apply to you? n estimated 631, businesses are affected by this OSH regulation. The majority of those affected are in the manufacturing and servicing industries. mong individual workers, equipment operators and those performing service on equipment are at the greatest risk of injury. Workers involved with packaging equipment, presses, and conveyor systems are also said to be at high risk. Who benefits? The Secretary of Labor says the procedures were developed to protect 39 million merican workers from injury, and more than six percent of all workplace deaths can be eliminated in the affected industries. Statistics indicate that implementation of the regulation could prevent 1 deaths and 6, injuries annually. How can this regulation be addressed? Guidelines for a Safe Workplace The rule requires equipment to have energy isolation devices (to isolate the equipment from its energy sources), and that such devices be capable of being locked in the off position. Formal procedures must be established to de-energize the equipment, isolate it, and ensure that any stored energy (for example, air pressure trapped downstream in a system) has been dissipated. Employee training in these procedures is mandatory. If your company uses pneumatically-controlled equipment, or if you are a manufacturer of pneumatically operated equipment, OSH rules can have a substantial effect on your business. s an employer, compliance may involve modifications to the air control systems for equipment in your plant. s a manufacturer, the new machines or equipment you deliver should include lockout-and-exhaust devices as a part of your standard package. 8.22

23 imba Manual Pneumatic Isolation Valves - PIV Series Key points regarding the control of pneumatic energy: Shut-off valve required Each piece of equipment must have a shut-off valve to isolate the equipment from its air supply and so render the equipment inoperative. Shut-off valve should be lockable The valve is lockable if it is designed to allow the use of a padlock to keep the valve in the closed position. Pressurized downstream air must be relieved In addition to locking out the air supply, all downstream air must be depressurized by providing an exhaust to atmosphere. Workers must also verify isolation and de-energizing, while being certain there is no reaccumulation of pressurized air during service or maintenance activities. Tagout may replace lockout only under certain circumstances (1) If energy isolation device cannot be locked out; Guidelines for a Safe Workplace (2) If employer shows that tagout provides safety equivalent to lockout. Whenever major replacement, repair, renovation, or modification of equipment is performed, or when new equipment is installed, energy isolating devices for such equipment must be designed to accept a lockout device. ir Preparation Equipment Manual Pneumatic Isolation Valves - PIV Series The imba PIV dvantage FETURES Teflon Seals Standard Integral Pressure Sensing Port Highest Flow Rates Push/Pull ctivation Valve can only be locked in the Off position Full or oversized exhaust ports ENEFITS Competitor s nitrile seals can extrude into the bore and stick; Teflon insures easy motion even after long periods of non-use. NSI/PMMI compliance; competitors need to T the line and add additional components. Quicker exhaust means more machine up time. Easy operation (NSI/PMMI) NSI/PMMI compliance; competitive rotary models can be locked in the partially on position which is a safety hazard and not in compliance with existing standards. NSI/PMMI compliance requires the exhaust port size to be greater than or equal to the supply port size. Many competitors have exhaust ports smaller than their supply ports. ll product is sold F.O.. shipping point. Prices are subject to change without notice For Technical ssistance:

24 Notes 8.24

25 Notes 8.25

26 Notes 8.26

Air Preparation Equipment

Air Preparation Equipment rochure ir Preparation quipment Setting a new standard for: Quality Reliability Value lobal ompatibility ilters M Series M ir Preparation quipment M -8-S-W- MOL imensions (mm, except where noted) RKT INLU

More information

Air Preparation Equipment

Air Preparation Equipment FRLS Improve system efficiency Side-by-side and stacking units available Modular design for easy connection and maintenance Variety of port sizes from #10-30 to 1" NPT pp. 170-174 FILTERS Capture solid

More information

Compressor Accessories

Compressor Accessories Compressor Accessories Series 11 Superior quality for superior performance COMPRESSOR OIL Description MINERAL 11.1100 1 litre container 11.1400 4 litre container SYNTHETIC 11.1200 1 litre container 11.1500

More information

AG INTERCHANGE IR I IRV I IRS SERIES POPPET INTERCHANGE COUPLERS Ag Style Interchange

AG INTERCHANGE IR I IRV I IRS SERIES POPPET INTERCHANGE COUPLERS Ag Style Interchange G INTERCHNGE IR I IRV I IRS SERIES POPPET INTERCHNGE COUPLERS g Style Interchange The griculture IR Series Hydraulic Quick Couplings offer automatic shut-off during disconnection. The IR features a variety

More information

Control Panel Regulators

Control Panel Regulators Control Panel Regulators Modular design for service & interchangeability Non-rising adjustment knob with push-pull lock ring feature Small package size and light weight construction Competitively priced

More information

Mechanically actuated valves

Mechanically actuated valves Mechanically actuated valves /2-5/2 spool valves with /8 NPT threaded ports Installation in any position Comprehensive range of actuations, direct or servo-piloted Special versions on request Materials

More information

AIR PREPARATION UNITS 3/4" NPT & 1" NPT SERIES

AIR PREPARATION UNITS 3/4 NPT & 1 NPT SERIES PNEUMATIC GROUP AIR PREPARATION UNITS 3/" NPT & " NPT SERIES 6 0, 0,6 0, 0,8 8 0,0 0 0 bar 6 0, 0,6 0, 0,8 8 0,0 0 0 bar 83 6 0, 0,6 0, 0,8 8 0,0 0 0 bar 6 0, 0,6 0, 0,8 0,0 0 0 bar 8 Port size Recommended

More information

Interchange Coupling. Poppet: Interchange Coupling

Interchange Coupling. Poppet: Interchange Coupling griculture Overview Stucchi griculture Series couplings are offered with a choice of either ball or poppet valve mechanisms for automatic shut-off during disconnection. The ball mechanism is the IR series,

More information

Misc: Interchange Coupling

Misc: Interchange Coupling Wing Style Interchange Coupling Misc: Interchange Coupling Series: W Interchange: Parker 6100 - Seals: Nitrile - Threaded sleeve allows connection/disconnection under pressure - Coupler: brass material

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

Table of Contents. Mark 3, SPA 3 & PA 3 Series

Table of Contents. Mark 3, SPA 3 & PA 3 Series Table of Contents...3-9 NSI Symbols... 3 Technical and Operating Data.... How to Order....5-6 Valve with ase....7-8 Manifold lock ssembly...9-0 Sandwich ressure Regulator.... Regulator Service Kits....

More information

Needle Valves Catalog 4110-NV December 2010

Needle Valves Catalog 4110-NV December 2010 Needle Valves Catalog 4110-NV December 2010 Series Needle Valves Catalog 4110-NV Introduction Parker Series nion onnet Valves have been engineered for use at pressures up to 6,000 (414 bar) and temperatures

More information

SUMMARY UNITS INTRODUCTION PAGE 2-4 KEY TO CODES PAGE 2-7 FILTER PAGE 2-8 DEPURATOR PAGE 2-11 ACTIVE CARBON FILTER PAGE 2-14.

SUMMARY UNITS INTRODUCTION PAGE 2-4 KEY TO CODES PAGE 2-7 FILTER PAGE 2-8 DEPURATOR PAGE 2-11 ACTIVE CARBON FILTER PAGE 2-14. SUMMARY INTRODUCTION PAGE - KEY TO CODES PAGE -7 FILTER PAGE -8 DEPURATOR PAGE - SUMMARY Syntesi ACTIVE CARBON FILTER PAGE - REGULATOR PAGE -7 IN-SERIES REGULATOR PAGE - FILTER-REGULATOR PAGE - LUBRICATOR

More information

3/4" NPT 3080 MF 185-3/4-US 1" NPT 3080 MF US

3/4 NPT 3080 MF 185-3/4-US 1 NPT 3080 MF US Port size Recommended flow Page No. (l/min) 1/8" NPT 125 MF 007-1/8-US 111-112 1/4" NPT 125 MF 007-1/4-US 1/8" NPT 200 MF 012-1/8-US 113-114 1/4" NPT 200 MF 012-1/4-US 3/8" NPT 200 MF 012-3/8-US 3/8" NPT

More information

TEKNOCRAFT INC. Proportional Valves. Mini Valves. Outlet Balanced Valves. Standard Valves. Your Proportional Valve Specialists

TEKNOCRAFT INC. Proportional Valves. Mini Valves. Outlet Balanced Valves. Standard Valves. Your Proportional Valve Specialists TEKNOCRAFT INC. Your Proportional Valve Specialists Proportional Valves Mini Valves Outlet Balanced Valves Standard Valves Table of Contents Teknocraft Unique Designs... 3 Mini Valves... 6 Outlet Balanced

More information

components IC, PB PSCK Pressure switches Digital pressure gauges Pressure gauges GA, GS NV, FM Gauge accessories A, AH/R HLS, H, T

components IC, PB PSCK Pressure switches Digital pressure gauges Pressure gauges GA, GS NV, FM Gauge accessories A, AH/R HLS, H, T Pressure switches t series IC, PB PSCK t page 188 Digital pressure gauges DG 189 Pressure gauges Gauge accessories Manifolds, couplers, hoses, tubing G GA, GS NV, FM A, AH/R HLS, H, T 190 191 192 High

More information

12 series (Pneufit) Push-in fittings

12 series (Pneufit) Push-in fittings > > Port size: Ø /8... /2, Ø 4... 2 mm tube size, SP and NPT threads > > Very compact units > > asy tube insertion for rapid assembly of pneumatic circuits > > Positive tube anchorage > > ll taper threads

More information

Model Filter. Lubricator PL2000 PL3000 PL4000 PL5000 Port size (NPT) Max. Supply Pressure Max. Operating Pressure Regulating Range.

Model Filter. Lubricator PL2000 PL3000 PL4000 PL5000 Port size (NPT) Max. Supply Pressure Max. Operating Pressure Regulating Range. Filter, Regulator, Lubricator Combinations PC2 PC3 MODULAR DESIGN EASY ASSEMBLY/DISASSEMBLY EASY MATENANCE FE OIL ADJUSTMENT (ONE-TOUC) BOWL GUARD ON UPC4, UPC5 REFILL UNDER PRESSURE Standard Specifications

More information

FITTINGS. Pneufit C composite and Pneufit M fittings Inch Ø 1/8" to 1/2" O/D tube

FITTINGS. Pneufit C composite and Pneufit M fittings Inch Ø 1/8 to 1/2 O/D tube Pneufit C composite and Pneufit M fittings Ø 1/8" to 1/2" Ready to use. Over 1,000 composite push-in pneumatic fittings. Releasable stainless-steel grab-ring to grip nylon or polyurethane (8 or 9 durometer).

More information

INTEGRAL-BONNET NEEDLE VALVES H-300 SERIES

INTEGRAL-BONNET NEEDLE VALVES H-300 SERIES INTEGRAL-BONNET NEEDLE VALVES SERIES INTEGRAL-BONNET NEEDLE VALVES SERIES FEATURES n Straight and angle pattern n Stainless Steel and Brass construction n MAWP 5000 psi (345 bar) n MAWT 446 F (230 C) n

More information

FILTER REGULATORS AND PARTS

FILTER REGULATORS AND PARTS COMPRESSED AIR ACCESSORIES PRICING 5-2017 WWW.RAPIDAIRPRODUCTS.COM 800-954-3310 FILTER REGULATORS AND PARTS 175psi MAX INLET, 0-150psi adjustment range PRICE QUANTITY K93210 INLINE REGULATOR W/GAUGE, 1/4"

More information

UMR Series Features and Benefits... 3 How to order... 3 Dimensionsder... 4

UMR Series Features and Benefits... 3 How to order... 3 Dimensionsder... 4 Table of Contents UMR Series...2-4 Features and enefits... 3 How to order... 3 Dimensionsder... 4 Numatics 2009 Rev. 1/06 2 UMR Series The UMR Series Mini Regenerative Desiccant Dryer offers a total cleaning

More information

Inline Filters (F Series) Catalog 4130-F July 2005

Inline Filters (F Series) Catalog 4130-F July 2005 Inline Filters (F Series) Catalog 4130-F July 2005 Catalog 4130-F Introduction Parker are designed for protection of instrumentation systems from undesirable materials. Component changes or repair and

More information

Contents. Coming soon from Teryair!!

Contents. Coming soon from Teryair!! Technical products for the ship suppl y industry Contents Teryair is a specialist manufacturer of precision pneumatic tools and marine industrial equipment. Our factories in Mumbai, India are certified

More information

BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM

BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / ACUUM LAB TABLE OF CONTENTS Content Page Table of Content 2 Product Overview 3 BROEN UniFlex TM BASIC 4-5 Fittings for Non-burnig 2.0 Gases/acuum Turret

More information

12 series (Pneufit) Push-in fittings Ø 1/8... 1/2, Ø mm tube size, BSP and NPT threads

12 series (Pneufit) Push-in fittings Ø 1/8... 1/2, Ø mm tube size, BSP and NPT threads 2 series (Pneufit) Push-in fittings Ø /8... /2, Ø 4... 2 mm tube size, SP and NPT threads Very compact units asy tube insertion for rapid assembly of pneumatic circuits Positive tube anchorage ll taper

More information

Impact resistant PBT body in black for Pneufit C and light gray for Pneufit M.

Impact resistant PBT body in black for Pneufit C and light gray for Pneufit M. Pneufit C composite and Pneufit M fittings Ø Â" to Ë" Ready to use. Over 1,000 composite push-in pneumatic fittings. Releasable stainless-steel grab-ring to grip nylon or polyurethane (85 or 95 durometer).

More information

H Series Pneumatic Screwdrivers and Nutrunners. Products and Solutions for Assembly

H Series Pneumatic Screwdrivers and Nutrunners. Products and Solutions for Assembly H Series Pneumatic Screwdrivers and Nutrunners Products and Solutions for Assembly About We are personally committed to understanding and exceeding our customers requirements. We are committed to continuously

More information

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I PORTO 2 VENT CPAP OS Operator s Manual 1 2 TABLE of CONTENTS 1. Introduction 3. Operating Instructions 1a. Definitions 3a. Setting the CPAP Level 1b. General Description 3b. Applying the Breathing Circuit

More information

DURASEAL. High Integrity, Double Block and Bleed Plug Valve.

DURASEAL. High Integrity, Double Block and Bleed Plug Valve. DURASEAL High Integrity, Double Block and Bleed Plug Valve www.franklinvalve.com How the DuraSeal Works An improved valve with a proven history We took an alternative path. Unlike many valve manufacturers

More information

Description. Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings

Description. Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings R Description Although Proximitor and interface are rugged by design, these units and their electrical connections

More information

SE Optimus Combination Shower and Eye And Face Wash System EYEWASH FEATURES: SHOWER FEATURES FINISH: OPTIONS: WARRANTY:

SE Optimus Combination Shower and Eye And Face Wash System EYEWASH FEATURES: SHOWER FEATURES FINISH: OPTIONS: WARRANTY: Optimus Combination Shower and Eye And Face Wash System EYEWASH FEATURES: Independent eye wash & face wash integrated into one, multi-functioning safety unit. Aerated sprays for eyewash comfort & innovative

More information

In-Line Accessories. In-Line Pressure Gauges. Pressure Gauges. In-Line Accessories

In-Line Accessories. In-Line Pressure Gauges. Pressure Gauges. In-Line Accessories Pressure Gauges Pressure gauges for monitoring system pressure Hoses and test points for sampling oil and determining ISO cleanliness levels Flanges to connect components Valves for system control In-Line

More information

AIR PREPARATION uality DOES matter!

AIR PREPARATION uality DOES matter! Qu ali ty DO E AIR PREPARATION S m at! r te AIR FILTER-REGULATOR-LUBRICATOR COMBINATION NAC 2000 01 D Model Range Body Size Port Size Manual Drain 2000 01: 1/8 NPT D Auto Drain 3000 02: 1/4 NPT 4000 03:

More information

Fittings, Tubing & Nipples

Fittings, Tubing & Nipples s, Tubing & Nipples P Series Pipe s s to 15,000 psi (1034 bar) Since 1945 utoclave Engineers has designed and built premium quality valves, fittings and tubing. This commitment to engineering and manufacturing

More information

Product Index by Coupler Style & Interchange

Product Index by Coupler Style & Interchange Product Index by Coupler Style & Interchange Flat Face Style Series Description Page # A Premier ISO 16028 Interchange Flat Face Coupling In accordance with ISO 16028 for Interchange and Performance. s:

More information

VALVES. Nugget 200 Spool Valves 1/4", 3/8", 1/2" NPT Air Pilot Actuated 3/2, 5/2, & 5/3 Inline Valves

VALVES. Nugget 200 Spool Valves 1/4, 3/8, 1/2 NPT Air Pilot Actuated 3/2, 5/2, & 5/3 Inline Valves Nugget 00 Spool Valves 1/", 3/8", 1/" NPT Air Pilot Actuated 3/, 5/, & 5/3 Inline Valves Long lasting spool design High flow compact valves Three functional types: available in 3/, 5/, and 5/3 configurations

More information

Installation Instructions

Installation Instructions Instructions Midrange Self-Contained Unit Accessory: Indeeco Electric Heat Used with Models SCWJ, SCRJ 3, 5, 7.5, 10, 12, and 15 Tons AO and later design sequence SAFETY WARNING Only qualified personnel

More information

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS 224500 SAFETY SHOWERS AND EYEWASHES PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 013010 Accessibility for People with Disabilities B. Section 115000 Laboratory Equipment

More information

Quick Sealing with a Twist to Connect Actuation Method

Quick Sealing with a Twist to Connect Actuation Method - Finger tighten seals up to 689 bar (10,000 psi) for pneumatic and hydraulic testing - Safe and Reliable leak tight connections to male and female threads - Eliminate thread damage, sealant and wrenches

More information

ROTARY UNION 9000 SERIES GENERAL PURPOSE MODELS ADDED MODELS ADDED. Operating Parameters FEATURES & BENEFITS MEDIA PRESSURE* TEMPERATURE* SPEED*

ROTARY UNION 9000 SERIES GENERAL PURPOSE MODELS ADDED MODELS ADDED. Operating Parameters FEATURES & BENEFITS MEDIA PRESSURE* TEMPERATURE* SPEED* ROTARY UNION 9 SERIES GENERAL PURPOSE Operating Parameters Steam, Hot Oil, Water MEDIA PRESSURE* 25 psi (Water), 75 psi (Steam), psi (Hot Oil) MODELS ADDED MODELS ADDED TEMPERATURE* 6 F (Hot Oil), 378

More information

In-Line Check Valves. Features. Valves. Working Pressures to: Flow Ranges to:

In-Line Check Valves. Features. Valves. Working Pressures to: Flow Ranges to: Valves In-Line Check Valves Working Pressures to: Flow Ranges to: 5700 psi/393 bar 200 gpm 757 lpm Features Steel constructed check valves are compatible with all non-corrosive liquids. Valves contain

More information

Fundamentals of Pressure Transducers

Fundamentals of Pressure Transducers print close Fundamentals of Pressure Transducers (Unpublished) Hydraulics & Pneumatics Alan Hitchcox Tue, 2013 09 17 (All day) Pressure is a key factor in almost every fluid power circuit. Pressure transducers

More information

S51 Series. Thread Together, Maximum Flow with Minimum Spillage

S51 Series. Thread Together, Maximum Flow with Minimum Spillage S51 Series S A F E W A Y H Y D R A U L I C S Document No. 7951 rev. 003 Thread Together, Maximum Flow with Minimum Spillage Minimum Spill, High Flow, Heavy-Duty Quick Coupling SafeWay s S51 Series is a

More information

DEBSON TM2 OXYGEN THERAPY FLOWMETERS WITH PRE ADJUSTED FLOWRATES. English version 09/2015

DEBSON TM2 OXYGEN THERAPY FLOWMETERS WITH PRE ADJUSTED FLOWRATES. English version 09/2015 DEBSON TM2 English version 09/2015 RAIL MOUNTING SYSTEMS 2 DIRECT PROBES 3 DEBSON TM2 The DEBSON TM2 is used to set the of a gas that is to be delivered to patients through the respiratory tract. It is

More information

PEEK SS Columns & Guard Columns

PEEK SS Columns & Guard Columns PEEK SS Columns & Guard Columns ~ Stainless Steel Analytical Columns ~ PEEK Columns ID 2.1, 4.0, 4.6 & 7.5 mm ~ Jour-Guard Cartridges Stainless Steel or PEEK ~ Stainless Steel End Fittings 1/4 OD Columns

More information

COST, PROCESS & QUALITY IMPROVEMENT

COST, PROCESS & QUALITY IMPROVEMENT COST, PROCESS & QUALITY IMPROVEMENT - Finger tighten seals up to 10,000 psi (689 bar) for pneumatic and hydraulic testing - Safe and Reliable leak tight connections to male and female threads - Eliminate

More information

VAL-212. Super X Manually & mechanically actuated spool valve In-line 3/2, 5/2 & 5/3, 1/8" & 1/4" NPT VALVES. 1/8" NPT 3/2 Mechanical Valves

VAL-212. Super X Manually & mechanically actuated spool valve In-line 3/2, 5/2 & 5/3, 1/8 & 1/4 NPT VALVES. 1/8 NPT 3/2 Mechanical Valves 3/, 5/ & 5/3, /8" & /4" NPT PRODUCTS FOR SAFE SYSTEMS* Wide range of operators Suitable for multi-directional flow and dual supply applications High flow capacity Lightweight corrosion resistant materials

More information

ore Mounting XP 9/16" (02) 3/4" (04) $27.15 $28.85 $28.95 $ /16" (09) $ /2" (17) $38.80 $32.85 $ " (31) $60.85 $65.80 ore Mounti

ore Mounting XP 9/16 (02) 3/4 (04) $27.15 $28.85 $28.95 $ /16 (09) $ /2 (17) $38.80 $32.85 $  (31) $60.85 $65.80 ore Mounti The model number of all P consists of three alphanumeric clusters. These designate product type, bore size and stroke length, and options. Please refer elrin nd ap ylinder ore Size 02 9/16" 04 3/4" 09

More information

Liquid ring vacuum pumps single-stage

Liquid ring vacuum pumps single-stage Liquid ring vacuum pumps single-stage LOH 20103, LOH 20107 Pressure range: Suction volume flow: 150 to 1013 mbar 7 to 58 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement pumps

More information

Fendall Pure Flow 1000 eyewash station, English Ea

Fendall Pure Flow 1000 eyewash station, English Ea Requirements specify that... suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area... Visit www.osha.gov for complete details and regulation requirements.

More information

Process lock Dalton. Use: Features: Door and hatches

Process lock Dalton. Use: Features: Door and hatches Process lock Dalton Use: Door and hatches Features: Small and robust Integrated with Eden High enclosure classification IP Withstands harsh enviroments Low current consumption Status information with LED

More information

Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT

Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT Platform concept conventional cigarettes e-cigarettes fast cleaning VITROCELL SMOKING ROBOT VC 10 S-TYPE Features all special requirements

More information

Hydraulic Motor & Brake

Hydraulic Motor & Brake whitedriveproducts SERIES 00-0 - 0 - HEVY DUTY Hydraulic Motor & rake DT DT (ll Series) For Heavy Duty pplications whitedriveproducts Overview series descriptions The most amazing aspect of the DT Series

More information

Adapters, Couplers and Fittings.

Adapters, Couplers and Fittings. Adapters, Couplers and Fittings www.alliedhpi.com 1 Table of Contents QUICK-CONNECT ADAPTERS AND COUPLERS Chemetron Quick-Connect Adapters 3 Chemetron Quick-Connect Adapters ISO 4 Chemetron Quick-Connect

More information

Side Channel R ing Blower

Side Channel R ing Blower Side Channel R ing Blower ------------------------------------- INSTRUCTION MNUL ------------------------------------ RB20../ 30../ 40../ 50../ 60 / 80.. SERIES CONTENT PGE 1. SFETY REQUIREMENT... 1 2.

More information

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line. Highlights Features ety of mounting flanges and output shafts options Benefits motor into a system tough applications Applications Description The 0 Series offers up to 0 in-lb of torque and gpm (continuous

More information

1105 Windham Parkway Romeoville, IL USA stucchiusa.com. Stucchi USA YOUR NEXT GREAT SOLUTION Product Catalog REV018

1105 Windham Parkway Romeoville, IL USA stucchiusa.com. Stucchi USA YOUR NEXT GREAT SOLUTION Product Catalog REV018 1105 Windham Parkway Romeoville, IL 60446 USA 847.956.9720 stucchiusa.com Stucchi USA YOUR NEXT GREAT SOLUTION Product Catalog REV018 YOUR NEXT GREAT SOLUTION Stucchi, Inc. provides high-quality hydraulic

More information

SureFlow. Oxygen Flow Station PROVIDER TECHNICAL MANUAL

SureFlow. Oxygen Flow Station PROVIDER TECHNICAL MANUAL SureFlow Oxygen Flow Station PROVIDER TECHNICAL MANUAL Table of Contents Definition of Product Symbols... 3 General Information... 3 Warning and Caution Statements...3 Introduction to the SureFlow Oxygen

More information

FasMate Quick Connectors Industry Applications:

FasMate Quick Connectors Industry Applications: FasMate Quick Connectors Industry Applications: The FasMate Series instantly seals threaded ports from vacuum up to 344.7 bar. The patented proprietary design makes sealing threaded ports as easy as 1,

More information

Helping to protect you from exposure to hazardous drugs

Helping to protect you from exposure to hazardous drugs Helping to protect you from exposure to hazardous drugs Closed system solution: Texium closed male luer and SmartSite needle-free valve products What you can t see can hurt you The risks are well documented

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS THANK YOU FOR CHOOSING reo sac THE REVOLUTIONARY REINFORCED RAINWATER STORAGE SYSTEM Before you begin, please take time to review the installation instructions and cross check

More information

AIR COOLED CONDENSERS

AIR COOLED CONDENSERS AIR COOLED CONDENSERS SELECTION GUIDE Data Aire, Inc. 230 W. BlueRidge Ave. Orange, CA 92865 www.dataaire.com TABLE OF CONTENTS DARC - Standard outdoor condenser general description... 3 DARC LD - Low

More information

Premium Chemical Free Iron/Sulphur Filter Installation Manual

Premium Chemical Free Iron/Sulphur Filter Installation Manual Premium Chemical Free Iron/Sulphur Filter Installation Manual 220 Bayview Avenue Unit 18 Barrie, Ontario, Canada, L4N 4Y8 www.excaliburwater.com EXCALIBUR PREMIUM CHEMICAL FREE IRON/SULPHUR FILTER INSTALLATION

More information

TECH 2 Dew Point Retrofit Kit

TECH 2 Dew Point Retrofit Kit TECH 2 Dew Point Retrofit Kit THORESON McCOSH TECH II Instruction Manual 412765A THORESON-McCOSH INC 1885 Thunderbird St. Troy MI. 48084 Phone 1-248-362-0960 Fax 1-248-362-5270 sales@thoresonmccosh.com

More information

Tru-Fit 10k Fittings

Tru-Fit 10k Fittings Tru-Fit 10k Fittings TruFit 10K Pipe and Adapter Fittings are designed and manufactured to provide a reliable connection in high pressure systems running to 10,000 psi. Manufactured from fully-traceable

More information

Today s Improved Compressed Air Piping Method

Today s Improved Compressed Air Piping Method STEP 1 STEP 2 STEP 3 (see page 8 for detailed instructions) Today s Improved Compressed Air Piping Method FAST INSTALLATION TIME -Aluminum piping is easy to cut and lift -O-ring seals ensure a leak free

More information

Plant, components and devices for very high and high pressures (7000 bar and over)

Plant, components and devices for very high and high pressures (7000 bar and over) Plant, components and devices for very high and high pressures (7000 bar and over) VALVES AND FITTINGS UP TO 1035 BAR MATERIALS All fittings are manufactured from EN 1.4404 / AISI 316L stainless steel

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL 1 2 Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

300 PRO FILTER VALVE OPERATING MANUAL. S.I.A.T.A. srl Società Italiana apparecchiature trattamento acqua MAN0028 Rev.

300 PRO FILTER VALVE OPERATING MANUAL. S.I.A.T.A. srl Società Italiana apparecchiature trattamento acqua MAN0028 Rev. 300 PRO FILTER VALVE OPERATING MANUAL S.I.A.T.A. srl Società Italiana apparecchiature trattamento acqua MAN0028 Rev. C Pag 1 di 27 300 PRO FILTER SERVICING MANUAL Document Revision Revision Note Date MAN0028

More information

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line. Highlights Features displacements, a variety of mounting flanges and output shafts Reliable, proven design High efficiency Environmental protection options Benefits Flexiblilty in designing this motor

More information

ADMINISTRATIVE DIRECTIVE

ADMINISTRATIVE DIRECTIVE ADMINISTRATIVE DIRECTIVE Title: Emergency Eyewash and Shower Stations Issuing Department: Town Manager s Safety Office Effective Date: June 1, 2014 Approved: Gilbert Davidson, Town Manager Type of Action:

More information

Check Valves PRODUCT DESCRIPTION FEATURES & BENEFITS TECHNICAL SPECIFICATIONS

Check Valves PRODUCT DESCRIPTION FEATURES & BENEFITS TECHNICAL SPECIFICATIONS Check Valves PRODUCT DESCRIPTION CPI check valves are designed for high pressure applications where reverse flow and leakage must be kept to a minimum. Typical applications include engine, pump and compressor

More information

MOUNTING ACCESSORIES, GAS HEATERS

MOUNTING ACCESSORIES, GAS HEATERS MOUNTING SSORIS, GS HTRS YLINDR RKTS Wall mount cylinder holders are an essential accessory to all manifolds. or safe containment of cylinders not greater than 9 12 in diameter. quipped with plated safety

More information

needle valves 3700, 3800, 3900 Series Forged Body, Integral Bonnet Needle Valves

needle valves 3700, 3800, 3900 Series Forged Body, Integral Bonnet Needle Valves orged ody, Integral onnet Needle Valves Offered in four different body materials, this group of valves can handle a wide range of general purpose liquid and gas applications. Six types of stem tips are

More information

The Do s and Don ts of Pressure Transducers

The Do s and Don ts of Pressure Transducers The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed

More information

Medescan Nebuliser Med - S600A Instructions Manual

Medescan Nebuliser Med - S600A Instructions Manual Medescan Nebuliser Med - S600A Instructions Manual Please read this guidebook carefully before operating this unit Your Nebuliser is intended for use in the treatment of asthma, COPD and other respiratory

More information

Portable Equine Nebuliser System. User Manual

Portable Equine Nebuliser System. User Manual Portable Equine Nebuliser System User Manual Table of Contents INTENDED USE... 3 SAFETY INFORMATION... 3 TECHNICAL SPECIFICATION... 4 INSTRUCTIONS FOR USE... 6 MAINTENANCE... 12 TROUBLESHOOTING... 13 WARRANTY...

More information

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual THS74/75 Industrial Temperature & Humidity Transmitter Operation Manual 1. Features 2. Security considerations 3. Installation 4. Connection 5. Display and LED instruction 6. Software setting and calibration

More information

KS1 CSM_KS1_DS_E_2_2

KS1 CSM_KS1_DS_E_2_2 Ionizer (ir Push Type) KS CSM_KS_DS_E Wide Range of Nozzles for Optimal Ionization wide range of nozzle variations High-frequency C method with excellent ion balance Refer to Safety Precautions on page

More information

Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan

Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan Installation manual ENGLISH www.simrad-yachting.com www.lowrance.com 1 Preface Warning: It is your sole responsibility to install

More information

BM, BMhp. Lenntech. Lenntech. Booster modules 50/60 Hz. Tel Fax.

BM, BMhp. Lenntech. Lenntech. Booster modules 50/60 Hz. Tel Fax. GRUNDFOS DATA BOOKLET BM, BMhp Booster modules 5/6 z Lenntech info@lenntech.com Tel. +31-152-61-9 www.lenntech.com Fax. +31-152-616-289 Lenntech BM, BMhp Table of contents 1. Performance ranges 3 BM, 5

More information

MEDICAL GAS FITTINGS & CONNECTIONS Quick Reference Guide

MEDICAL GAS FITTINGS & CONNECTIONS Quick Reference Guide MEDICAL GAS FITTINGS & CONNECTIONS Quick Reference Guide www.baycorporation.com ISO 9001 ISO 13485 Follow us: 867 Canterbury Rd., Westlake, OH 44145 USA P: 440.835.2212 888.835.3800 F: 440.835.1377 E:

More information

Union Bonnet Valves - VU6 Series

Union Bonnet Valves - VU6 Series BlowOur Proof Back Seating Hardened Stem Thread Mountable Panel nut Metal Seal Bonnet Union Bonnet Valves VU6 Series Features Pressure rating up to 6000psig (13bar) @38 C (100 F) Temperature rating from

More information

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT Instruction Manual TABLE OF CONTENTS IEC Symbols...2 Important Safeguards...2 Introduction...3 Specifications...4

More information

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0 The sensor series SONOFLOW CO.55/xxx V2.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. For applications on

More information

Needle Valves. We deliver confidence through quality products

Needle Valves. We deliver confidence through quality products We deliver confidence through quality products INTRODUCTION NEEDLE VALVES SD range of Needle valves come in various sizes, sealing styles, end connections and stem types. They are available in bar stock

More information

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION TABLE OF CONTENTS EDITION 5 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2 - INTRODUCTION 2.1. INTRODUCTION 3 Section 3 - GENERAL 3.1. UNPACKING AND INSTALLATION

More information

Double Block and Bleed ball valve have evolved to replace the process of bolting together individual valves to provide dual isolation.

Double Block and Bleed ball valve have evolved to replace the process of bolting together individual valves to provide dual isolation. Bleed valve Double Block and Bleed ball valve have evolved to replace the process of bolting together individual valves to provide dual isolation. This new assembly provides great savings in weight, space

More information

Product Catalog 2016 EMEA

Product Catalog 2016 EMEA Product Catalog EMEA 2016 PORTFOLIO SOL-M Standard medical devices SOL-GUARD Basic safety medical devices SOL-CARE Innovative and advanced safety-engineered medical devices Sol-Millennium Europe Sp. z

More information

Pulsation Systems. Setting the standard for durable and consistent pulsation

Pulsation Systems. Setting the standard for durable and consistent pulsation Pulsation Systems Setting the standard for durable and consistent pulsation 2 GEA PULSATION SYSTEMS Detacher-controlled pulsation systems Electronically efficient diaphragm pulsators The Stimopuls Apex

More information

Ross Brown Sales Pty. Ltd. Portable Pressure/Vacuum Comparator

Ross Brown Sales Pty. Ltd. Portable Pressure/Vacuum Comparator Ross Brown Sales Pty. Ltd. Portable Pressure/Vacuum Comparator The data provided above is for information purposes only and no warranty of accuracy or reliability is given. Page 17 of 30 Pressure Generating

More information

SUN VALLEY STOVE COMPANY

SUN VALLEY STOVE COMPANY LO HI ON PILOT LO HI ON PILOT SUN VALLEY STOVE COMPANY VENT-FREE NATURAL GAS STOVE HEATER ILLUSTRATED PARTS BREAKDOWN MSVFBNR 1 2 6 21 3 7 4 21 11 22 9 12 23 10 13 OFF 1 17 24 14 16 17 1 19 OFF 12 OWNER

More information

V-TEK Hygienic Butterfly Valves

V-TEK Hygienic Butterfly Valves STINLSS STLS LT. V-TK Hygienic utterfly Valves V-TK utterfly Valves have proven functionality and reliability. esigned in 1998, the V-TK valve allows full interchangeability of most handles, actuators

More information

Adapters Quick Reference Guide

Adapters Quick Reference Guide Adapters Quick Reference Guide Minimizing Downtime in a Variety of Industries Construction Demolition Distribution Equipment Rental Excavation Manufacturing Marine Material Handling Municipalities Recycling

More information

ULTR A SERIES G7-S23

ULTR A SERIES G7-S23 ULTR A SERIES G7-S3 PROPER USAGE 1. Do not exceed weight limits of the exercise device.. If applicable, set safety stops to appropriate height. 3. If applicable, adjust seat pads, leg pads, foot pads,

More information

Pulsation Systems. Setting the standard for durable and consistent pulsation. Detacher controlled. Master controlled. Individual. Vacuum operated.

Pulsation Systems. Setting the standard for durable and consistent pulsation. Detacher controlled. Master controlled. Individual. Vacuum operated. Pulsation Systems Setting the standard for durable and consistent pulsation n n n n Detacher controlled. Master controlled. Individual. Vacuum operated. GEA Milking & Cooling WestfaliaSurge Detacher controlled

More information

ULTR A SERIES G7-S75

ULTR A SERIES G7-S75 ULTR A SERIES G7-S75 2 PROPER USAGE 1. Do not exceed weight limits of the exercise device. 2. If applicable, set safety stops to appropriate height. 3. If applicable, adjust seat pads, leg pads, foot pads,

More information

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors Datasheet BR Series /CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the /CSA C22.2 No.5-02, UL1077/CSA

More information