Comparison of Muscle Image Acquisition & Analysis Techniques
|
|
- Primrose Reed
- 5 years ago
- Views:
Transcription
1 Comparison of Muscle Image Acquisition & Analysis Techniques Toronto General Research Institute Andy Kin On Wong PhD Assistant UHN Scientist Scanco User Meeting, September 20, :15 pm
2 Muscle & Bone Measures in vivo 200 um 195 um pqct 500 um 500 um 1.0T pmri Muscle density (MD) Muscle cross-sectional area (MCSA) Subcutaneous fat area vbmd, bone microstructural & mechanical properties Muscle area / volume Subcutaneous, inter & intramuscular fat volume Muscle proton density Bone microstructure, area
3 1. T1-Weighted Fast Spin Echo MRI TR/TE: 600/21 ms, NEX = 3, echoes = 2, flip angle=40 o, bandwidth=25 khz, 10 x 1.0 mm thick contiguous slices 195 µm in-plane resolution Issue: Muscle and bone cannot be separated by using fixed thresholds Subcutaneous fat INTERmuscular fat Fascia line Muscle Adult with diabetes Older Adult INTRAmuscular fat Younger Adult
4 Participants with a range of muscle adiposity can be observed Can be performed on the GE 1.0T pmri within 10 minutes Or on any clinical MRI scanner
5 Patterned Involvement of Muscle Dystrophy
6 MRI inter/intra-muscular fat (IMF) segmentation & quantification Watershed Algorithm Region-growing Algorithm IMF Area (IMF.A) IMF Volume (IMF.V) Watershed lines guide separation of different tissue regions Region-growing algorithm colours in tissues within signal range
7 Precision of Manually-Segmented IMF Measures Short-term test-retest pmri/pqct Variable All Participants N=51 No Fx and No Antiresorptives N=17 RMSCV RMSSD LSC RMSCV RMSSD LSC MRI IMF.A (mm 2 ) 10.6% % MRI IMF.V (mm 3 ) 6.1% % One-year test-retest N=33 N=14 MRI IMF.A (mm 2 ) 14.9% % MRI IMF.V (mm 3 ) 17.1% % IMF volume accounts for up to 54% of the variance in muscle density
8 Semi-Automated Segmentation of IMF Manual exclusion of bone and subcutaneous fat Seed point & thresholding Dichotomize Island Pruning Island Pruning Revised threshold applied & and looped until T R (iteration n) = T R (iteration n-1) New muscle (M i ) and IMF (F i ) seed values revised threshold (T R ) T R = 1 + M i F i F i M i
9 Final Segmented IMF
10 Manual IMF Area (mm 2 ) pqct-derived Muscle Density (mg/cm3) Precision of Semi-Automatically Segmented IMF Measures Study Comparison Variable N RMSCV RMSSD ICC Hamilton CaMos(N=43) Test-Retest MCSA mm Age: 74.6±8.9 y Test-Retest IMFA mm BMI: 25.60±4.61 kg/m 2 Test-Retest pimfa % y = 1.14x R² = Semi-Auto IMF Area (mm 2 ) y = -0.43x R² = 0.47 y = -0.81x R² = Percentage IMF Area (%) (Auto or Manual)
11 Automated Segmentation of IMF
12 Other MR Imaging Techniques Fat/Water-suppression pulses Chemical Shift Fat-Water Separation (IDEAL, 3 Point Dixon) Diffusion tensor imaging MR Spectroscopy
13 Challenges with MR Imaging 1. Signal inhomogeneity (full body scanners) 2. Amplified fat signal (T1 and T2 bias) 3. Imperfect suppression pulses 4. Spectral complexities of fat 5. Eddy currents (phase shift)
14 Partial volume artifact mm mm mm mm mm Figure 1. Comparison of intramuscular fat discernibility among images of varying resolutions.
15 Muscle Quantification on peripheral Quantitative Computed Tomography (pqct) -Measures muscle area, volume, density -Proxy for inter+intra-muscular fat pqct (Stratec XCT 2000) ISSUE: Muscle and fat must be separated from one another and from bone 500 µm Outer threshold 40 mg/cm 3 Inner threshold 40 mg/cm 3 Filter: F03F05F05 Contour Mode: 3 Peel Mode: 2
16 Failed muscle segmentations Manually re-segment around muscle fascia
17 Precision & Accuracy of pqct Muscle Outcomes Reliability Data RMSCV (% error) Variable & Method Young Older SCI Water-Shed MD (mg/cm 3 ) Threshold MD (mg/cm 3 ) Water-Shed MCSA (mm 2 ) Threshold MCSA (mm 2 ) SCI = Spinal Cord Injury Muscle density accounts for 54% of the variance in inter+intramuscular fat
18 Muscle Quantification on HR-pQCT Soft Tissue Evaluation Tool
19 HR-pQCT Muscle Segmentation Seed volume identities: Fat threshold: mgha/cm 3 Muscle threshold: to mgha/cm 3 Algorithm Seed volumes Planted Unconnected volumes removed Seed volumes Iteratively expanded Areas of overlap undefined Areas of overlap mgha/cm 3 Muscle / Fat FINAL IMAGE 20 Iterations
20 Comparison with pqct Post-menopausal women (n=45) Age (years) 74.6 (8.5) Height (m) 1.62 (0.07) Weight (kg) 68.0 (11.6) BMI (kg/m 2 ) 25.9 (4.3) TUG (seconds) 11.3 (3.4) Grip Strength (kg) 24.0 (6.0) pqct HR-pQCT HR-pQCT (66% Site) (HA calibration) (HU calibration) MD 70.0 (5.0) mg/cm (4.7) mg/cm (13.4) HU MCSA 5738 (899) mm (242) mm (250) mm 2 Muscle Volume (2.1) cm (2.1) cm 3
21 pqct 66% Muscle Density (mg/cm 3 ) pqct 66% Muscle Area (mm 2 ) Relationship between pqct (prox) & HR-pQCT Muscle (distal) Measurement R 2 P-val B Beta Int MD (mg/cm 3 ) < (0.089,0.283) MCSA (mm 2 ) < (1.227,3.231) Simple linear regression analysis HR-pQCT 22.5 mm site Muscle Density (Houndsfield Units) HR-pQCT 22.5 mm site Muscle Area (mm 2 )
22 XtremeCT2 Calf Imaging
23 ~ 66% Site Muscle Analysis on XtremeCT2
24 ~ 66% Site Muscle Analysis on XtremeCT2 Sample Name Site MV cm 3 MV/TV MD mg/cm 3 Fat Density mg/cm 3 Calf_test#003 Tibia L Calf_test#001 Tibia L Calf_test#004 Tibia L Calf_test#005 Tibia L Calf_test#006 Tibia L Calf_test#006 Radius R
25 Ultrasound Achilles Tendon Imaging GE Logiq E Portable USI Systems (12 MHz, linear transducer B- mode) OsiriX Manual contouring of Achilles Tendon CSA Images obtained from transverse scan Tendon CSA obtained values averaged between three scans
26 Achilles Tendon on HR-pQCT Standard HR-PQCT distal tibia scan 22.5 mm site Soft Tissue Analysis Applied a) b) c) A) Semi-automatic contour of the limb. B) Soft-tissue contours generated for semi-automatic threshold algorithm. C) Manually edited contours around Achilles tendon.
27 Difference HR-pQCT vs. Ultrasound TCSA (cm 2 ) Comparison of HR-pQCT and Ultrasound-derived Tendon CSA SD Mean Women and Men (>50 years) Mean Age = 63.2 years Mean BMI = 24.9 kg/m SD TCSA Measurements Variable N Mean SD HR-pQCT Ultrasound Average of HR-pQCT and Ultrasound Tendon CSA (cm 2 )
28 Mean Ultrasound Tendon CSA (cm 2 ) Comparison of HR-pQCT and Ultrasound-derived Tendon CSA HR-pQCT vs Ultrasound TCSA Correlation Plot Correlation: r = 0.703, p=0.002 ICC (2,1) Using Consistency Definition ICC LCI UCI Single Measure Average Measur Mean HR-pQCT Tendon CSA (cm 2 )
29 T2 Relaxation (ms) MRI & QCT-Compatible Muscle Calibration Phantom T2 Relaxation (ms) Density (mg/cm 3 ) Phantom Properties Fatty Muscle Average Muscle Lean Muscle [CuCl 2 ] 4.00 mm mm mm [EDTA] 0.73 mm 0.03 mm 0.01 mm T2 relaxation time ms ms ms Density 65 mg/cm mg/cm mg/cm CuCl 2 Concentration (mmol/l) CuCl2 Concentration (mmol/l) D = 0.27[CuCl 2 ] , R 2 = 0.84, p = 0.01 T2 = ln[CuCl 2 ] , R 2 =0.91, p<0.01 T2 = 5.72 ln[edta]+54.47, R 2 =0.86, p< EDTA Concentration (mmol/l)
30 Odds for a Fragility Fracture Effect of Muscle Fractures Conditional on Frailty CaMos Frailty Index Johnson-Neyman technique Identified CFI values: 0.05 to 0.13 as region in which effect of Muscle Density Fractures were significant Vertical lines = 95% confidence intervals Points = Point estimate Muscle Cross- Sectional Area & Muscle Mass: Frailty showed no moderation effect
31 Canadian Musculoskeletal Imaging Network Calgary, AB U of C, Foothills Hospital (hr-pqct, pmri, DXA) Vancouver, BC CHHM, VCH (hr-pqct, pqct, DXA) Saskatoon, SK U of Saskatchewan (hr-pqct, pqct, DXA) Hamilton Coordinating Centre Adachi Medicine, McMaster (pqct, pmri, DXA) Hamilton, ON St. Peter s, HHS (DXA, pmri planned) Ottawa, ON CHEO, U of Ottawa (pqct, DXA) Montreal, QC Shriner s Hospital (pqct, DXA) Kingston, ON Queen s U, HMRC (pqct, DXA) Toronto, ON TGH, JDMI, UHN (hr-pqct, pqct pmri, DXA)
32 Participation from over 12 academic institutions and over 16 Canadian investigators across five provinces in Canada
Investigating the Effects of Motion Streaks on pqct-derived Leg Muscle Density and Its Association With Fractures
Journal of Clinical Densitometry: Assessment & Management of Musculoskeletal Health, vol. 21, no. 1, 130 139, 2018 Copyright 2016 by The International Society for Clinical Densitometry 1094-6950/21:130
More informationIntroduction. Original Article. Abstract
J Musculoskelet Neuronal Interact 2014; 14(4):401-410 Original Article Hylonome Peripheral quantitative computed tomography-derived muscle density and peripheral magnetic resonance imaging-derived muscle
More informationQuadriceps Muscle and Intermuscular Fat Volumes in the Thighs of Men in the OAI are Associated with Physical Function and Knee Pain
Quadriceps Muscle and Intermuscular Fat Volumes in the Thighs of Men in the OAI are Associated with Physical Function and Knee Pain Karen A. Beattie, Monica R. Maly, Sami Shaker, Norma J. MacIntyre McMaster
More informationpqct Measurement of Bone Parameters in Young Children
Journal of Clinical Densitometry, vol. 3, no. 1, 9 14, Spring 2000 Copyright 2000 by Humana Press Inc. All rights of any nature whatsoever reserved. 0169-4194/00/3:9 14/$11.50 Original Article pqct Measurement
More informationLiver Fat Quantification
Liver Fat Quantification Jie Deng, PhD, DABMP Department of Medical Imaging May 18 th, 2017 Disclosure Research agreement with Siemens Medical Solutions 2 Background Non-alcoholic fatty liver diseases
More information2013 ISCD Official Positions Adult
2013 ISCD Official Positions Adult These are the Official Positions of the ISCD as updated in 2013. The Official Positions that are new or revised since 2007 are in bold type. Indications for Bone Mineral
More informationCover Page. The handle holds various files of this Leiden University dissertation.
Cover Page The handle http://hdl.handle.net/1887/35124 holds various files of this Leiden University dissertation. Author: Wokke, Beatrijs Henriette Aleid Title: Muscle MRI in Duchenne and Becker muscular
More informationACR MRI Accreditation: Medical Physicist Role in the Application Process
ACR MRI Accreditation: Medical Physicist Role in the Application Process Donna M. Reeve, MS, DABR, DABMP Department of Imaging Physics University of Texas M.D. Anderson Cancer Center Educational Objectives
More informationACR MRI Accreditation Program. ACR MRI Accreditation Program Update. Educational Objectives. ACR accreditation. History. New Modular Program
ACR MRI Accreditation Program Update Donna M. Reeve, MS, DABR, DABMP Department of Imaging Physics University of Texas M.D. Anderson Cancer Center Educational Objectives Present requirements of the new
More informationL.W. Sun 1,2, G. Beller 1, D. Felsenberg 1. Introduction. Original Article. Abstract
J Musculoskelet Neuronal Interact 2009; 9(1):18-24 Original Article Hylonome Quantification of bone mineral density precision according to repositioning errors in peripheral quantitative computed tomography
More informationExperimental Assessment of Infarct Lesion Growth in Mice using Time-Resolved T2* MR Image Sequences
Experimental Assessment of Infarct Lesion Growth in Mice using Time-Resolved T2* MR Image Sequences Nils Daniel Forkert 1, Dennis Säring 1, Andrea Eisenbeis 2, Frank Leypoldt 3, Jens Fiehler 2, Heinz Handels
More informationRemoval of Nuisance Signal from Sparsely Sampled 1 H-MRSI Data Using Physics-based Spectral Bases
Removal of Nuisance Signal from Sparsely Sampled 1 H-MRSI Data Using Physics-based Spectral Bases Qiang Ning, Chao Ma, Fan Lam, Bryan Clifford, Zhi-Pei Liang November 11, 2015 1 Synopsis A novel nuisance
More informationUnderwater Acoustic Measurements in Megahertz Frequency Range.
Underwater Acoustic Measurements in Megahertz Frequency Range. Current State and Prospects of Development in Russia Alexander M. Enyakov,, Many medical applications of underwater acoustic measurements
More informationLeast significant changes and monitoring time intervals for high-resolution pqct-derived bone outcomes in postmenopausal women
J Musculoskelet Neuronal Interact 2015; 15(2):190-196 Original Article Hylonome Least significant changes and monitoring time intervals for high-resolution pqct-derived bone outcomes in postmenopausal
More informationQuantitative Computed Tomography 4 Introduction
Quantitative Computed Tomography 4 Introduction Quantitative Computed Tomography (QCT) is a well recognised technique for the measurement of bone mineral density (BMD) in the lumbar spine1 and forearm2.
More informationAPPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS
APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS Jeffrey P. Milligan, Daniel T. Peters, Structural Integrity Associates, Inc., USA Many advances in Non-Destructive Examination
More informationConfident and Conclusive Diagnosis with Flexible Solutions
Internal Medicine Confident and Conclusive Diagnosis with Flexible Solutions ALPINION MEDICAL SYSTEMS We are Ultrasound Professionals Ultrasound is widely used as the gold-standard for internal medicine
More informationIn vivo diffusion tensor imaging (DTI) of articular cartilage as a biomarker for osteoarthritis
In vivo diffusion tensor imaging (DTI) of articular cartilage as a biomarker for osteoarthritis Jose G. Raya 1, Annie Horng 2, Olaf Dietrich 2, Svetlana Krasnokutsky 3, Luis S. Beltran 1, Maximilian F.
More informationCT Imaging of skeleton in small animals. Massimo Marenzana
CT Imaging of skeleton in small animals Massimo Marenzana Introduction Osteoporosis is a disease in which bones become fragile and more likely to break. It can be defined as a systemic skeletal disease
More informationThis article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.
This is the peer reviewed version of the following article: S, Smith & A. M. Madden (2016) Body Composition and functional assessment of nutritional status in adults: a narrative review of imaging, impedance,
More informationULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS
1 OB/Gyn (Core) Ultrasound Principles of Ultrasound Physics and Instrumentation Nathan Pinkney, BS, CDOS Philadelphia College of Osteopathic Medicine 2016 ULTRASOUND CATEGORIES OF SOUND INFRASOUND = below
More informationMetabolism Core. History: Services: Metabolism Core Published on Nutrition & Obesity Research Center (
Metabolism Core The Metabolism Core was designed to provide state-of-the-art assessments of human energy expenditure, substrate metabolism, body composition, body fat distribution, and bone quality; to
More informationInterpreting DEXA Scan and. the New Fracture Risk. Assessment. Algorithm
Interpreting DEXA Scan and the New Fracture Risk Assessment Algorithm Prof. Samir Elbadawy *Osteoporosis affect 30%-40% of women in western countries and almost 15% of men after the age of 50 years. Osteoporosis
More information2013 ISCD Combined Official Positions
2013 ISCD Combined Oicial Positions Oicial Positions of the International Society for Clinical Densitometry The International Society for Clinical Densitometry (ISCD) is a not-for-profit multidisciplinary
More informationLOGIQ V2. Simple. Fast. Precise. Empowering Point of Care Medicine.
LOGIQ V2 Simple. Fast. Precise. Empowering Point of Care Medicine. Challenges in Point of Care: Chronic patient management. Needle guidance. Action-oriented patient care. Physicians who use ultrasound
More informationDevelopment of a Viable Bedside Ultrasound Protocol to Accurately Predict Appendicular Lean Tissue Mass
Development of a Viable Bedside Ultrasound Protocol to Accurately Predict Appendicular Lean Tissue Mass by Michael Paris A thesis presented to the University of Waterloo in fulfillment of the thesis requirement
More informationAssessment of Adipose Tissue from Whole Body 3T MRI Scans
Assessment of Adipose Tissue from Whole Body 3T MRI Scans Ting Song 1, Jing An 2, Qun Chen 2, Vivian Lee 2, Andrew Laine 1 1 Department of Biomedical Engineering, Columbia University, New York, NY, USA
More informationBone Densitometry Radiation dose: what you need to know
Bone Densitometry Radiation dose: what you need to know John Damilakis, PhD Associate Professor and Chairman University of Crete, Iraklion, Crete, GREECE Estimation of bone status using X-rays Assessment
More informationConsortium of MS Centres Guidelines Revised Standardized MRI Protocol. for the Diagnosis and Follow-up of MS. David K.B.
Consortium of MS Centres Guidelines Revised Standardized MRI Protocol for the Diagnosis and Follow-up of MS David K.B. Li MD FRCPC Indianapolis, Indiana May 27, 2015 Disclosure I have received research
More informationA new method of sonograph lateral resolution measurement using PSF analysis of received signal
A new method of sonograph lateral resolution measurement using PSF analysis of received signal L. Doležal, J. Hálek Faculty of Medicine Palacký University in Olomouc, Czech Republic E-mail: ladol@tunw.upol.cz
More informationGE Healthcare 9900 Innovation Drive Wauwatosa, WI U.S.A.
2011 General Electric Company All rights reserved. General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time
More informationThis is a repository copy of Microarchitecture of bone predicts fractures in older women.
This is a repository copy of Microarchitecture of bone predicts fractures in older women. White Rose Research Online URL for this paper: http://eprints.whiterose.ac.uk/130351/ Version: Accepted Version
More informationMethods of MR Fat Quantification and their Pros and Cons
Methods of MR Fat Quantification and their Pros and Cons Michael Middleton, MD PhD UCSD Department of Radiology International Workshop on NASH Biomarkers Washington, DC April 29-30, 2016 1 Disclosures
More informationQuality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.
Quality Assurance of Ultrasound Imaging in Radiation Therapy Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St. Louis, Missouri Typical Applications of Ultrasound Imaging in Radiation Therapy
More informationCover Page. The handle holds various files of this Leiden University dissertation.
Cover Page The handle http://hdl.handle.net/1887/35124 holds various files of this Leiden University dissertation. Author: Wokke, Beatrijs Henriette Aleid Title: Muscle MRI in Duchenne and Becker muscular
More informationULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah
ULTRASOUND IMAGING EE 472 F2018 Prof. Yasser Mostafa Kadah www.k-space.org Recommended Textbook Diagnostic Ultrasound: Physics and Equipment, 2nd ed., by Peter R. Hoskins (Editor), Kevin Martin (Editor),
More informationRECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE
In Practice RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE By Atsuya Watanabe, MD, PhD, Director, Advanced Diagnostic Imaging Center and Associate Professor, Department of Orthopedic Surgery, Teikyo
More informationBody Composition in NASH Clinical Trials
Body Composition in NASH Clinical Trials Jonathan Riek, PhD VP, Musculoskeletal and Metabolic Imaging, BioTel Research Olof Dahlqvist Leinhard, PhD Chief Scientific Officer & Co-Founder, AMRA 2/26/2018
More informationHigh Field MR of the Spine
Department of Radiology University of California San Diego 3T for MR Applications Advantages High Field MR of the Spine Increased signal-to-noise Better fat suppression Increased enhancement with gadolinium
More informationDevelopment of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion
Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion Jason Silver August 26, 2009 Presentation Outline Introduction Thesis Objectives Mathematical Model and Principles Methods
More informationVarian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System
Varian Edge Experience Jinkoo Kim, Ph.D Henry Ford Health System Disclosures I participate in research funded by Varian Medical Systems. Outline of Presentation Review advanced imaging in Varian Edge Linear
More informationTable 1. Summary of PET and fmri Methods. What is imaged PET fmri BOLD (T2*) Regional brain activation. Blood flow ( 15 O) Arterial spin tagging (AST)
Table 1 Summary of PET and fmri Methods What is imaged PET fmri Brain structure Regional brain activation Anatomical connectivity Receptor binding and regional chemical distribution Blood flow ( 15 O)
More informationContrast, Elastography and 3D in MSK Ultrasound
Advances in Musculoskeletal US Contrast, Elastography and 3D in MSK Ultrasound Nandkumar Rawool, MD, RDMS Associate Professor, Department of Radiologic Sciences Program Director, Diagnostic Medical Sonography
More informationA. DeWerd. Michael Kissick. Larry. Editors. The Phantoms of Medical. and Health Physics. Devices for Research and Development.
Larry Editors A. DeWerd Michael Kissick The Phantoms of Medical and Health Physics Devices for Research and Development ^ Springer Contents 1 Introduction to Phantoms of Medical and Health Physics 1 1.1
More information3D Dosimetry with Polymer Gel
3D Dosimetry with Polymer Gel Yoichi Watanabe, Ph.D. University of Minnesota Minneapolis, MN NCCAAPM Meeting, Minneapolis, MN NCCAAPM Meeting, Minneapolis, MN April 28, 2006 Outline I. Basics of polymer
More informationIn-vivo precision of the GE Lunar idxa for the measurement of visceral adipose tissue in
1 2 In-vivo precision of the GE Lunar idxa for the measurement of visceral adipose tissue in adults: the influence of body mass index 3 4 Running title: Precision of the idxa for the measurement of visceral
More informationA New Approach For an Improved Multiple Brain Lesion Segmentation
A New Approach For an Improved Multiple Brain Lesion Segmentation Prof. Shanthi Mahesh 1, Karthik Bharadwaj N 2, Suhas A Bhyratae 3, Karthik Raju V 4, Karthik M N 5 Department of ISE, Atria Institute of
More informationULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS
ULTRASOUND QA SOLUTIONS Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS INNOVATORS IN ADVANCED ULTRASOUND TECHNIQUES Gammex is the
More informationBone Densitometry at the Point of Care
Bone Densitometry at the Point of Care EchoS is the first radiation free solution for the early diagnosis of Osteoporosis at the axial sites. A breakthrough echographic device for bone characterization
More informationA quality control program for MR-guided focused ultrasound ablation therapy
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 3, NUMBER 2, SPRING 2002 A quality control program for MR-guided focused ultrasound ablation therapy Tao Wu* and Joel P. Felmlee Department of Radiology,
More informationFulfilling the Promise
Fulfilling the Promise of Cardiac MR Non-contrast, free-breathing technique generates comprehensive evaluation of the coronary arteries By Maggie Fung, MR Cardiovascular Clinical Development Manager; Wei
More informationTrends in adult obesity
53 by Margot Shields and Michael Tjepkema Keywords: body mass index, body weight, income, smoking In recent years, the percentage of Canadian adults with excess weight has increased considerably, part
More informationSONIMAGE HS1. Premium Portable Ultrasound
SONIMAGE HS1 Premium Portable Ultrasound EXIT SET F2 F1 User User Gain FREEZE PREMIUM PORTABLE ULTRASOUND DESIGNED FOR YOU Sonimage HS1 2 Sonimage HS1 is Konica Minolta s Premium Portable Ultrasound designed
More informationSensitivity and Specificity in Detection of Labral Tears with 3.0-T MRI of the Shoulder
Magee and Williams MRI for Detection of Labral Tears Musculoskeletal Imaging Clinical Observations C M E D E N T U R I C L I M G I N G JR 2006; 187:1448 1452 0361 803X/06/1876 1448 merican Roentgen Ray
More informationPrinciples of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012
Principles of Ultrasound Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012 None Disclosures Outline Introduction Benefits and Limitations of US Ultrasound (US) Physics
More informationValidating FE predictions of distal radius failure load: standard region and 4% region
Validating FE predictions of distal radius failure load: standard region and 4% region M Hosseinitabatabaei, N Soltan, M McDonald, C Kawalilak, G Johnston, S Kontulainen, JD Johnston Fixed Scan Position
More informationMeniscus T2 Relaxation Time at Various Stages of Knee Joint Degeneration
Meniscus T2 Relaxation Time at Various Stages of Knee Joint Degeneration Richard Kijowski, Michael Fazio, Benjamin Beduhn, and Fang Liu Department of Radiology University of Wisconsin School of Medicine
More informationTerminology Tissue Appearance
By Marc Nielsen, MD Advantages/Disadvantages Generation of Image Ultrasound Machine/Transducer selection Modes of Ultrasound Terminology Tissue Appearance Scanning Technique Real-time Portable No ionizing
More informationBasic of Ultrasound Physics E FAST & Renal Examination. Dr Muhammad Umer Ihsan MBBS,MD, DCH CCPU,DDU1,FACEM
Basic of Ultrasound Physics E FAST & Renal Examination Dr Muhammad Umer Ihsan MBBS,MD, DCH CCPU,DDU1,FACEM What is Sound? Sound is Mechanical pressure waves What is Ultrasound? Ultrasounds are sound waves
More informationPurpose. Methods and Materials
Fat fraction of bone marrow measured by Dixon quantitative chemical shift magnetic resonance imaging in the lumbar spine: does it have a significant correlation with bone mineral density and age or menopause?
More informationMagnetic Resonance Imaging. Basics of MRI in practice. Generation of MR signal. Generation of MR signal. Spin echo imaging. Generation of MR signal
Magnetic Resonance Imaging Protons aligned with B0 magnetic filed Longitudinal magnetization - T1 relaxation Transverse magnetization - T2 relaxation Signal measured in the transverse plane Basics of MRI
More informationpowerful versatile mobile
M9 Premium Compact Ultrasound System powerful versatile mobile M9 Premium Compact Ultrasound System powerful versatile mobile Powerful Platform With the next generation of technologies, the Mindray M9
More informationULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS
ULTRASOUND QA SOLUTIONS Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS INNOVATORS IN ADVANCED ULTRASOUND TECHNIQUES Gammex is the
More informationMuscle-bone relationships in the lower leg of healthy pre-pubertal females and males
J Musculoskelet Neuronal Interact 2008; 8(3):239-243 Original Article Hylonome Muscle-bone relationships in the lower leg of healthy pre-pubertal females and males T.L. Binkley and B.L. Specker Ethel Austin
More informationSegmentation of Tumor Region from Brain Mri Images Using Fuzzy C-Means Clustering And Seeded Region Growing
IOSR Journal of Computer Engineering (IOSR-JCE) e-issn: 2278-0661,p-ISSN: 2278-8727, Volume 18, Issue 5, Ver. I (Sept - Oct. 2016), PP 20-24 www.iosrjournals.org Segmentation of Tumor Region from Brain
More informationDETERMINATION OF OXALIPLATIN DOSE IN ADJUVANT CHEMOTHERAPY : VALIDATION OF A DEDICATED SOFTWARE BASED ON INITIAL CT SCAN
DETERMINATION OF OXALIPLATIN DOSE IN ADJUVANT CHEMOTHERAPY : VALIDATION OF A DEDICATED SOFTWARE BASED ON INITIAL CT SCAN R Tetreau, M Theillac, F Castan, P Senesse, V Baracos 07 APRIL 2016 BACKGROUND 1
More information2D-Sigmoid Enhancement Prior to Segment MRI Glioma Tumour
2D-Sigmoid Enhancement Prior to Segment MRI Glioma Tumour Pre Image-Processing Setyawan Widyarto, Siti Rafidah Binti Kassim 2,2 Department of Computing, Faculty of Communication, Visual Art and Computing,
More informationNew Dual-energy X-ray Absorptiometry Machines (idxa) and Vertebral Fracture Assessment
Case 1 New Dual-energy X-ray Absorptiometry Machines (idxa) and Vertebral Fracture Assessment (VFA) History and Examination Your wealthy friend who is a banker brings his 62-year-old mother to your office
More informationFat Suppression in the Abdomen
Clinical How I do it? Fat Suppression in the Abdomen Wilhelm Horger Siemens Medical Solutions, Erlangen, Germany Introduction Due to the different chemical environment, hydrogen nuclei in - and in -tissue
More informationCoronary artery disease (CAD) risk factors
Background Coronary artery disease (CAD) risk factors CAD Risk factors Hypertension Insulin resistance /diabetes Dyslipidemia Smoking /Obesity Male gender/ Old age Atherosclerosis Arterial stiffness precedes
More informationPatients with diffuse idiopathic skeletal hyperostosis do not have increased peripheral bone mineral density and geometry
RHEUMATOLOGY Rheumatology 2010;49:977 981 doi:10.1093/rheumatology/keq014 Advance Access publication 15 February 2010 Concise report Patients with diffuse idiopathic skeletal hyperostosis do not have increased
More informationBrain tissue and white matter lesion volume analysis in diabetes mellitus type 2
Brain tissue and white matter lesion volume analysis in diabetes mellitus type 2 C. Jongen J. van der Grond L.J. Kappelle G.J. Biessels M.A. Viergever J.P.W. Pluim On behalf of the Utrecht Diabetic Encephalopathy
More informationD. Doré 1, C. Ding 1,2, J.P. Pelletier 3, J. Martel-Pelletier 3, F. Cicuttini 2, G. Jones 1.
Responsiveness of qualitative and quantitative MRI measures over 2.7 years D. Doré 1, C. Ding 1,2, J.P. Pelletier 3, J. Martel-Pelletier 3, F. Cicuttini 2, G. Jones 1. 1 Menzies Research Institute Tasmania,
More informationInterleaved Water and Fat Imaging and Applications to Lipid Quantitation Using the Gradient Reversal Technique
JOURNAL OF MAGNETIC RESONANCE IMAGING 26:1064 1070 (2007) Original Research Interleaved Water and Fat Imaging and Applications to Lipid Quantitation Using the Gradient Reversal Technique Haiying Tang,
More information9 Quality Assurance in Bone Densitometry section
9 Quality Assurance in Bone Densitometry section Introduction Bone densitometry is frequently used to determine an individual's fracture risk at a particular point in time but may also be used to assess
More informationMR Advance Techniques. Vascular Imaging. Class II
MR Advance Techniques Vascular Imaging Class II 1 Vascular Imaging There are several methods that can be used to evaluate the cardiovascular systems with the use of MRI. MRI will aloud to evaluate morphology
More informationMUSCLE SIZE AND SPECIFIC FORCE ALONG THE LENGTH OF THE QUADRICEPS IN OLDER AND YOUNG INDIVIDUALS
MUSCLE SIZE AND SPECIFIC FORCE ALONG THE LENGTH OF THE QUADRICEPS IN OLDER AND YOUNG INDIVIDUALS Hannah Barile Faculty Advisor: Dr. Summer Cook 2014 University of New Hampshire. All rights reserved. Introduction
More informationMusculoskeletal Imaging at 3T with Simultaneous Use of Multipurpose Loop Coils
Clinical Orthopedic Imaging Musculoskeletal Imaging at 3T with Simultaneous Use of Multipurpose Loop Coils Elena Ferrer 1 ; Rafael Coronado Santos 2 1 Radiology Department, Clínica Creu Blanca, Barcelona,
More informationBone Mineral Densitometry with Dual Energy X-Ray Absorptiometry
Bone Mineral Densitometry with Dual Energy X-Ray Absorptiometry R Gilles, Laurentius Ziekenhuis Roermond 1. Introduction Osteoporosis is characterised by low bone mass, disruption of the micro-architecture
More informationT2, T2*, ute. Yeo Ju Kim. Radiology, Inha University Hospital, Incheon, Korea
SY28-1 T2, T2*, ute Yeo Ju Kim Radiology, Inha University Hospital, Incheon, Korea T2 relaxation times relate to the rate of transverse magnetization decay, caused by the loss of phase coherence induced
More informationBackground. New Cross Hospital is a 700 bed DGH located in central England
Background New Cross Hospital is a 700 bed DGH located in central England Regional Heart & Lung centre opened in 2005 Covering the Black Country (Population >1,000,000) Nuclear Medicine Department Single
More informationAssessing Bone Quality in Terms of Bone Mineral Density, Buckling Ratio and Critical Fracture Load
J Bone Metab 01;1:- http://dx.doi.org/10.1100/jbm.01.1.. pissn - eissn -0 Original Article Assessing Bone Quality in Terms of Bone Mineral Density, Buckling Ratio and Critical Fracture Load Anitha D 1,
More informationVisualization strategies for major white matter tracts identified by diffusion tensor imaging for intraoperative use
International Congress Series 1281 (2005) 793 797 www.ics-elsevier.com Visualization strategies for major white matter tracts identified by diffusion tensor imaging for intraoperative use Ch. Nimsky a,b,
More informationSaphenous Vein Wall Thickness in Age and Venous Reflux-Associated Remodeling in Adults
Saphenous Vein Wall Thickness in Age and Venous Reflux-Associated Remodeling in Adults Nicos Labropoulos Professor of Surgery Director, Vascular Laboratory Division of Vascular Surgery Stony Brook Medicine
More informationRepeatability of 2D FISP MR Fingerprinting in the Brain at 1.5T and 3.0T
Repeatability of 2D FISP MR Fingerprinting in the Brain at 1.5T and 3.0T Guido Buonincontri 1,2, Laura Biagi 1,3, Alessandra Retico 2, Michela Tosetti 1,3, Paolo Cecchi 4, Mirco Cosottini 1,4,5, Pedro
More information4D Auto LAQ (Left Atrial Quantification)
4D Auto LAQ (Left Atrial Quantification) Introduction There has been an increased interest in quantification of the left atrium (LA) for various types of diseases; e.g. heart failure, heart valve diseases,
More informationImproved Inspection of Composite Wind Turbine Blades with Accessible Advanced Ultrasonic Phased Array Technology
Improved Inspection of Composite Wind Turbine Blades with Accessible Advanced Ultrasonic Phased Array Technology André Lamarre Olympus Scientific Solutions Americas, Canada NDT of Composites an ASNT Topical
More informationSupplementary Online Content
Supplementary Online Content Gregg NM, Kim AE, Gurol ME, et al. Incidental cerebral microbleeds and cerebral blood flow in elderly individuals. JAMA Neurol. Published online July 13, 2015. doi:10.1001/jamaneurol.2015.1359.
More informationClinical Introduction
Clinical Introduction 4th XtremeCT User Meeting Dr.med. Stephanie Finzel, MD University of Freiburg, Freiburg, Germany 2 Assessment of Periarticular Joint Alterations Scan: 2 nd - 4 th MCPJ of the clinically
More informationDr Emma Chung. Safety first - Physical principles for excellent imaging
Safety first - Physical principles for excellent imaging Dr Emma Chung Lecturer in Medical Physics, University of Leicester Clinical Scientist, University Hospitals of Leicester NHS Trust Thanks to Caroline
More informationSignificance of MRI in diagnostics, outcome prognosis and definition the therapeutic tactics for cases of aseptic necrosis of the femoral head
Significance of MRI in diagnostics, outcome prognosis and definition the therapeutic tactics for cases of aseptic necrosis of the femoral head Abstract: 539 Congress: ESMRMB 2013 Type: Scientific Poster
More informationResearch Article Development of Automatic Visceral Fat Volume Calculation Software for CT Volume Data
Obesity, Article ID 495084, 7 pages http://dx.doi.org/10.1155/2014/495084 Research Article Development of Automatic Visceral Fat Volume Calculation Software for CT Volume Data Mitsutaka Nemoto, 1 Tusufuhan
More informationPeripheral Quantitative CT (pqct) Using a Dedicated Extremity Cone-Beam CT Scanner
SPIE Medical Imaging 23 Peripheral Quantitative CT (pqct) Using a Dedicated Extremity Cone-Beam CT Scanner A. A. Muhit, a S. Arora, a M. Ogawa, a Y. Ding, a W. Zbijewski, a J. W. Stayman, a G. Thawait,
More informationMast Cell Tryptase Modifies The Contraction Of Human Joint Capsule Cells In Vitro
Mast Cell Tryptase Modifies The Contraction Of Human Joint Capsule Cells In Vitro Kevin A. Hildebrand, MD 1, Lindsey M. Logan 1, Mei Zhang 1, David A. Hart, PhD 1, Paul T. Salo, MD 1, A. Dean Befus, PhD
More informationFull ultrasound breast volumes. Faster scans. Streamlined workflow. ACUSON S2000 Automated Breast Volume Scanner. Answers for life.
Full ultrasound breast volumes. Faster scans. Streamlined workflow. ACUSON S2000 Automated Breast Volume Scanner Answers for life. 1 ACQUIRE An automated whole breast solution. Reduced acquisition time.
More informationFeasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011
Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011 Electrical and Computer Engineering Department Volgenau School of Engineering George
More informationHigh resolution ultrasound scanner for skin imaging
High resolution ultrasound scanner for skin imaging Christine Turlat Sales Director Atys medical 17 Parc d Arbora 69510 SOUCIEU EN JARREST Atys company Principle of ultrasound imaging DERMCUP Normal image
More informationOrthopedic Hardware Imaging Part II: MRI v. Metal
Orthopedic Hardware Imaging Trent Roth, MD And Lauren Ladd, MD Indiana University School of Medicine IU Health Physicians-Radiology Recap: Imaging Techniques Radiography Standard for initial and surveillance
More informationA Method to Monitor Local Changes in MR Signal Intensity in Articular Cartilage: A Potential Marker for Cartilage Degeneration in Osteoarthritis
A Method to Monitor Local Changes in MR Signal Intensity in Articular Cartilage: A Potential Marker for Cartilage Degeneration in Osteoarthritis Josephine H. Naish 1, Graham Vincent 2, Mike Bowes 2, Manish
More information3/25/2010. Age-adjusted incidence rates for coronary heart disease according to body mass index and waist circumference tertiles
Outline Relationships among Regional Adiposity, Physical Activity, and CVD Risk Factors: Preliminary Results from Two Epidemiologic Studies Molly Conroy, MD, MPH Obesity Journal Club February 18, 2010
More information