Acute ischemic coronary syndromes often result from the

Size: px
Start display at page:

Download "Acute ischemic coronary syndromes often result from the"

Transcription

1 Noninvasive In Vivo Human Coronary Artery Lumen and Wall Imaging Using Black-Blood Magnetic Resonance Imaging Zahi A. Fayad, PhD; Valentin Fuster, MD, PhD; John T. Fallon, MD, PhD; Timothy Jayasundera, MD; Stephen G. Worthley, MD; Gerard Helft, MD; J. Gilberto Aguinaldo, MD; Juan J. Badimon, PhD; Samin K. Sharma, MD Background High-resolution MRI has the potential to noninvasively image the human coronary artery wall and define the degree and nature of coronary artery disease. Coronary artery imaging by MR has been limited by artifacts related to blood flow and motion and by low spatial resolution. Methods and Results We used a noninvasive black-blood (BB) MRI (BB-MR) method, free of motion and blood-flow artifacts, for high-resolution (down to 0.46 mm in-plane resolution and 3-mm slice thickness) imaging of the coronary artery lumen and wall. In vivo BB-MR of both normal and atherosclerotic human coronary arteries was performed in 13 subjects: 8 normal subjects and 5 patients with coronary artery disease. The average coronary wall thickness for each cross-sectional image was mm (range, 0.55 to 1.0 mm) in the normal subjects. MR images of coronary arteries in patients with 40% stenosis as assessed by x-ray angiography showed localized wall thickness of mm (range, 3.30 to 5.73 mm). The difference in maximum wall thickness between the normal subjects and patients was statistically significant (P ). Conclusions In vivo high-spatial-resolution BB-MR provides a unique new method to noninvasively image and assess the morphological features of human coronary arteries. This may allow the identification of atherosclerotic disease before it is symptomatic. Further studies are necessary to identify the different plaque components and to assess lesions in asymptomatic patients and their outcomes. (Circulation. 2000;102: ) Key Words: atherosclerosis magnetic resonance imaging coronary disease Acute ischemic coronary syndromes often result from the rupture of a mildly to moderately stenotic coronary artery plaque, leading to thrombus formation. 1 3 Currently available imaging techniques for the diagnosis of coronary artery disease are limited. For example, coronary angiography demonstrates only the degree of luminal narrowing and fails to visualize the arterial wall. Moreover, arteries accommodate plaque growth through outward displacement of the vessel wall, thereby preserving lumen cross-sectional area. 4 Other imaging techniques, such as intravascular ultrasound, 5 fast CT, 6 and angioscopy, 7 have all advanced our understanding of atherosclerosis, but these techniques are invasive and yield limited information about plaque composition. Recent in vivo studies of atherosclerotic plaques in animal models, 8,9 carotid arteries, 10,11 and aorta 12 demonstrate that high-resolution MRI can noninvasively image the artery wall and assess plaque composition. Preliminary studies in a porcine model of atherosclerosis showed that the major difficulties of MR coronary wall imaging are due to the combination of cardiac and respiratory motion artifacts, the nonlinear course of the coronary arteries, and their relatively small size and location. 13 Thus, an effective in vivo MRI technique for coronary artery imaging must overcome artifacts related to blood flow and cardiac, respiratory, and vessel wall motion to achieve high-resolution and high-contrast imaging. Current white-blood non contrast-enhanced MR coronary angiography (gradient-echo, 14 echo planar, 15 spiral, 16 etc) provide no information about the coronary wall structure or atherosclerotic plaque characteristics. In this context, the concept of black-blood MRI (BB-MR) is promising, because the signal from static tissue is maximized and the transverse magnetization of flowing blood is made intentionally incoherent, leading to blood signal void. 17,18 Therefore, by combining BB-MR with high-spatialresolution and fast-data-acquisition imaging, both lumen and wall imaging of the coronary arteries should be possible. A number of different methods are available for BB-MR However, none of these methods have been used for coronary lumen and wall imaging. In this in vivo study of normal and atherosclerotic human coronary arteries, we use long-echo-train-length (ETL) fastspin-echo (FSE) imaging with velocity-selective inversion preparatory pulses 22,23 to nullify the signal from flowing Received November 15, 1999; revision received February 22, 2000; accepted February 29, From the Zena and Michael A. Wiener Cardiovascular Institute (Z.A.F., V.F., J.T.F., T.J., S.G.W., G.H., J.G.A., J.J.B., S.S.) and the Departments of Radiology (Z.A.F.), Medicine (V.F., J.T.F., J.J.B., S.S.), and Pathology (J.T.F.), Mount Sinai School of Medicine, New York, NY. Correspondence to Zahi A. Fayad, PhD, Mount Sinai School of Medicine, Box 1234, New York, NY zahi.fayad@mssm.edu 2000 American Heart Association, Inc. Circulation is available at 506

2 Fayad et al In Vivo MRI of Human Coronary Atherosclerosis 507 blood. A cardiac phased-array surface coil for high-resolution coronary imaging (460- to 750- m in-plane spatial resolution) is also used. 24 The results of this study clearly demonstrate that normal and atherosclerotic human coronary wall imaging can be performed with high-resolution BB-MR methods. Methods Subjects We studied 13 subjects: 8 healthy subjects (mean age, 30 years; range, 25 to 37 years; 4 men) without a history of cardiovascular disease and 5 consecutive coronary artery disease patients (mean age, 68 years; range, 50 to 78 years; 3 men) with 40% stenosis as documented by x-ray angiography. The MRI studies were performed within 24 hours of the coronary contrast x-ray angiogram. Written informed consent was obtained from all subjects, and the institutional review board approved the protocol. MR Imaging MRI was performed on a 1.5-T whole-body MRI system (General Electric Medical Systems, Signa) equipped with high-performance gradient (40-mT/m amplitude, 150-mT m 1 ms 1 slew rate) and a multichannel receiver with a maximal bandwidth of 250 khz. A 4-element (2 anterior and 2 posterior) specially designed cardiac phased-array receiver surface coil was used for signal reception. 24 ECG electrodes were attached to trigger data acquisition and minimize cardiac and vessel motion. All subjects were instructed to withhold breathing at end expiration to minimize respiratory motion. Breath-holding was confirmed by a bellows respiratory monitor. Imaging Sequence Fast scout gradient-echo images were acquired initially in the coronal, sagittal, and transverse planes for localization. All imaging was subsequently performed with a BB-MR sequence. The major features of the BB-MR sequence are (1) velocity-selective inversion preparatory pulses; (2) short RF excitation pulses; (3) optimized fat saturation; and (4) long-etl FSE imaging. Velocity-Selective Inversion Preparatory Pulses Velocity-selective inversion preparatory pulses were used to suppress the signal from flowing blood, thereby avoiding possible flow artifacts and providing a strong contrast between the dark flowing blood and bright wall signal of the coronary arteries. The flow suppression consisted of 2 inversion pulses: 1 nonselective 180 inversion recovery (IR) pulse followed immediately by a sliceselective 180 inversion pulse. 22 The first IR pulse inverts the magnetization of the entire body, including all of the blood. Next, the second IR pulse reinverts the imaging slice but leaves the blood outside the slice inverted. The section thickness of the selective inversion pulse was set to 3 times the slice thickness to accommodate possible misregistration of tissue between the preparatory pulses and data acquisition. The nonselective pulse consisted of a rectangular hard pulse 1024 s long. The selective pulse was a hyperbolicsecant pulse 8640 s long. 25 This provided good B1 insensitivity and inversion profile. The velocity-selective inversion pulses were placed at end diastole (after the detection of the ECG trigger), and the data acquisition occurred during diastole. This process maximized the blood flow suppression due to outflow and also minimized artifacts due to vessel motion. Image acquisition started after a predetermined inversion time (TI). The delay time or TI for the velocity-selective inversion preparatory pulses was determined close to the null point of the blood signal (see equation). TI is based on the T1 relaxation value of the blood and the TR interval: TI T1 1 e TR T1. 2 With TR 2 RR 1000 ms (heart rate 60 bpm) and T ms, from the equation, TI is 625 ms. Short Optimized RF Pulses The data acquisition is performed with an FSE sequence. As usual for the FSE sequence, the time between the 90 excitation pulse and the first refocusing pulse is half the time between the neighboring refocusing pulses (the echo spacing; ESP). The strong and fast gradients made possible very compact echo trains. To further shorten the ESP, short radiofrequency (RF) pulses optimized by use of the Shinnar-LeRoux algorithm were used. 26 The RF excitation pulses were 1.2 ms long. The refocusing pulse had a flip angle of 155. With a data acquisition sampling of 125 khz and 256 frequency points, an ESP as short as 3.9 ms was achievable. These pulses provided reduced power deposition and reduced echo amplitude unstabilities Optimized Fat Suppression In acquiring images of the coronary artery wall, the velocityselective inversion pulses were immediately followed by a chemical shift selective (CHESS) pulse. This pulse eliminated the epicardial fat signal and thus enhanced the definition of the outer boundary of the arteries. To take account of the multicomponent nature of the fat signal, the CHESS pulse was optimized according to Kuroda et al 30 and resulted in improved fat suppression and coronary wall visualization. Long-ETL FSE Imaging The preparatory pulses (velocity-selective inversion pulses and CHESS pulse) were followed by an ECG-gated, long-etl FSE imaging sequence. The short ESP allowed the use of long-etl data acquisition without the disadvantage of T2 relaxation blurring. 31 From the initial scout images of the coronary arteries, 5 contiguous transverse (cross-sectional) images of the lumen and wall of the proximal segments of the right (RCA) and left anterior descending (LAD) coronary arteries were acquired in 13 subjects. Imaging was performed during short periods of suspended respiration of 12 to 18 heartbeats per slice. One way to restrict the number of phaseencoding steps is to reduce the field of view (FOV) in the phaseencoding direction. However, for a small FOV, this may result in back-folding artifacts. Therefore, when this was the case, we disabled the 2 posterior coil elements of our 4-coil-elements anterior and posterior phased-array coil by a user-controlled variable just before imaging. The imaging parameters were TR 2 RR intervals, TE 40 ms, asymmetric (3/4) FOV in the phase encoding direction (in some of the images), 18- to 29-cm FOV, 3- to 5-mm slice thickness, no interslice gap, or acquisition matrix, number of signals averaged (NSA) 1, 32 ETL, 125-kHz data sampling. The in-plane resolution was 0.46 to 0.75 mm. Image Analysis The MR images were transferred to a Macintosh computer for analysis. The inner (ie, lumen) and outer (eg, adventitial-medial) boundaries of the vessels were traced semiautomatically with ImagePro Plus (Media Cybernetics). The semiautomatic tracing tool works by following an edge (ie, boundary) of significant contrast. The maximal wall thickness was determined from each crosssectional image. The data were then analyzed with a 2-tailed unpaired Student s t test. A value of P 0.05 was considered to be statistically significant. Values are mean SEM. Results All the images demonstrated excellent flow suppression and high contrast and signal-to-noise in the coronary arteries and clearly delineated the coronary wall. Cross-sectional images of normal coronary artery wall showed a circular lumen surrounded by a uniform thin wall (Figure 1). A transverse lumen image obtained without fat saturation (Figure 1A) and wall image obtained with fat saturation (Figure 1B) of the

3 508 Circulation August 1, 2000 Figure 1. In vivo cross-sectional BB-MR images of lumen (A) and wall (B) of proximal LAD from normal subject (see arrow). Lumen image is obtained without fat saturation; wall image is obtained with fat saturation to better delineate coronary artery wall. Blood flow in coronary artery lumen is suppressed with velocity-selective inversion preparatory pulses. Images show normal circular lumen surrounded by uniform thin coronary wall. Average wall thickness of LAD measures 0.8 mm. B, Inset, Magnified view of LAD. Some imaging parameters were TR 2 RR intervals, TE 40 ms, cm FOV, 3-mm slice thickness, acquisition matrix, NSA 1, 32 echo train length, 125- khz data sampling. LV indicates left ventricle; RV, right ventricle; RVOT, right ventricular outflow tract; and CW, chest wall. proximal LAD from a normal subject are shown. In this subject, the maximum wall thickness of the LAD measures 0.8 mm. Figure 2 shows the ectatic atherosclerotic coronary arteries and thickened coronary wall of a 45-year-old male patient. The BB-MR cross-sectional lumen image reveals a circular lumen and an anterior plaque (arrow, Figure 2A). The cross-sectional image of the wall clearly reveals a variably thick proximal RCA, with the wall thinner around the 6 o clock position and thicker in the other sectors (Figure 2B). In that patient, the maximum wall thickness is 3.3 mm. Figure Figure 2. In vivo cross-sectional BB-MR images of lumen (A) and wall (B) of RCA from 45-year-old male patient with ectatic atherosclerotic coronary arteries and thickened coronary wall. Lumen image is obtained without fat saturation; wall image is obtained with fat saturation to better delineate coronary artery wall. Blood flow in coronary artery lumen is suppressed with velocity-selective inversion preparatory pulses. Maximum wall thickness is 3.3 mm. BB-MR cross-sectional lumen image reveals circular lumen and anterior plaque (arrow, A). Crosssectional image of wall clearly reveals variably thick proximal RCA, with wall thinner around 6 o clock position and thicker in other sectors (B). B, Inset, Magnified view of RCA. Some imaging parameters were TR 2 RR intervals, TE 40 ms, cm FOV, 5-mm slice thickness, acquisition matrix, NSA 1, 32 echo train length, 125-kHz data sampling. LA indicates left atrium; RA, right atrium; other abbreviations as in Figure 1. Figure 3. X-ray angiogram from 78-year-old female patient with mild disease on x-ray angiography in proximal LAD (arrow, A). BB-MR cross-sectional lumen image reveals circular lumen (B); wall shows uniformly thickened LAD wall (B) with concentric plaque (maximum thickness 4.13 mm) (C). C, Inset, Magnified view of LAD. Blood flow in coronary artery lumen is suppressed with velocity-selective inversion preparatory pulses. Some imaging parameters were TR 2 RR intervals, TE 40 ms, cm FOV, 4-mm slice thickness, acquisition matrix, NSA 1, 32 echo train length, 125-kHz data sampling. Abbreviations as in Figure 1. 3A shows mild disease in the proximal LAD as seen on x-ray angiography in a 78-year-old female patient. The BB-MR cross-sectional lumen image reveals a circular lumen (Figure 3B), and the wall image shows a concentric plaque (maximum thickness of 4.13 mm) (Figure 3C). Figure 4A shows high-grade stenosis in the proximal LAD on the x-ray angiogram in a 76-year-old male patient. The cross-sectional coronary image at that location shows an obstructed lumen (elliptical shape) on the BB-MR lumen image (Figure 4B). The BB-MR wall image obtained with fat saturation reveals a large eccentric plaque measuring 5.73 mm with heterogeneous signal intensity, possibly due to the different tissue composition (Figure 4C). In the normal subjects, the average maximum coronary wall thickness was mm (range, 0.55 to 1.0 mm; n 40). MR images of coronary arteries in coronary artery disease patients showed atherosclerotic plaques 3.30 to 5.73 mm in maximum wall thickness ( mm; n 25). The difference in maximum coronary wall thickness between the normal subjects and patients was statistically significant (P ). Discussion This study demonstrates, for the first time, that in vivo MRI can provide high-spatial-resolution images of the coronary artery wall in normal and diseased human arteries. Vessel lumen and wall morphology in normal and atherosclerotic human coronary arteries was assessed with a high-resolution

4 Fayad et al In Vivo MRI of Human Coronary Atherosclerosis 509 Figure 4. X-ray angiogram from 76-year-old male patient shows high-grade stenosis in proximal LAD (arrows, A). In vivo crosssectional BB-MR images of LAD lumen (B) shows obstructed lumen (elliptical lumen shape); wall image (C) shows large eccentric plaque with heterogeneous signal intensity (maximum thickness 5.73 mm). Blood flow in coronary artery lumen is suppressed with velocity-selective inversion preparatory pulses. Some imaging parameters were TR 2 RR intervals, TE 40 ms, cm FOV, 4-mm slice thickness, acquisition matrix, NSA 1, 32 echo train length, 125-kHz data sampling. Abbreviations as in Figure 1. BB sequence consisting of the long-etl FSE imaging method with velocity-selective inversion preparatory pulses to eliminate the signal from the flowing blood. The coronary artery wall was clearly seen in all patients and had a distinct MR signal characteristic of surrounding tissue. Data obtained from comparative studies with standard histology and epivascular and intravascular ultrasound are in close agreement with the results of our study Moreover, a recent study in pigs using a similar MRI technique showed an excellent correlation between matched in vivo coronary wall images and histopathology sections for average wall thickness. 36 As seen in Figures 1 through 4, the in-plane spatial resolution used in this study (460 to 750 m) was adequate for the distinction between normal and diseased portions of the coronary arteries and to quantify coronary artery wall and plaque thickness. Possible Further Improvements The slice thickness of the MR image (3 to 5 mm) causes volume averaging (ie, partial-volume effect) and can contribute to an overestimation of the coronary wall. Thinner slice thickness, as used with 3D acquisition techniques, could further improve our coronary artery wall imaging. 18,37 Moreover, zero-filled interpolation of the images can be used to create images to reduce the partial-volume effects in imaging pixels. 38 This can be achieved by appending zeros on each side of the data before Fourier transformation. A relatively high spatial resolution of 0.46 to 0.75 mm was achieved by use of a specially tailored phased-array coil. Other coil designs, such as a smaller anterior 4-element phased-array coil, may improve the spatial resolution and allow the identification of the substructures within atherosclerotic coronary lesions. The BB FSE sequence used in this study has flexible multicontrast capabilities (ie, proton-density or T2 weighting through direct manipulation of TE), which, with improvements in spatial resolution and image contrast, may allow the characterization of the different coronary plaque components. 9,11,12,44,45 A misalignment of the imaging plane and the long axis of the vessel can lead to inaccurate cross-sectional images and lead to errors in wall thickness measurements and plaque imaging. Careful planning in this study minimized these errors. A 3D imaging sequence 18,37 will allow image reformatting in any desired plane direction and thus ensure the proper alignment between the imaging plane and the course of the coronary arteries. The effect of slowly flowing blood near the vessel walls is another phenomenon that could potentially degrade the accuracy of vessel wall imaging with BB techniques. However, preliminary results in our study and with a similar BB-MR sequence in the coronary arteries 36 and in the brain 46 suggest that this effect is minimal. Breath-holding was used to suppress respiratory motion. This limits the maximal duration of the scan and may not be possible in certain patients. We have limited the breathholding duration to 12 to 18 heartbeats (12 to 18 seconds for heartbeats of 60 bpm), which was well tolerated by all subjects. Adequate breath-holding was confirmed by respiratory bellows. Short breath-holding limits the achievable spatial resolution and data sampling for each image, which in turn leads to vessel wall imaging. These problems can be overcome only by a prolongation of the duration of the breath-holds, which is well tolerated in some patients, or by the use of navigator techniques to avoid breath-holding altogether. 47,48 The reduction of the ESP will also lead to shorter breath-holds and reduction of vessel motion blurring. We have visualized the major epicardial coronary arteries but not the side branches. However, coronary atherosclerosis most often involves the proximal portion of the coronary arteries, usually at or near branch sites. 49 Evaluation of the whole extent of the epicardial coronary arteries will be developed in future studies. Moreover, validation and repeatability studies of the MRI findings need to be performed, possibly in patients undergoing intravascular ultrasound. Clinical Implications Atherosclerotic coronary artery plaque rupture is a key event leading to acute coronary syndromes. In vivo MRI provides a means to noninvasively image and assess the morphological features of atherosclerotic and normal human coronary arteries. Future work will certainly aim at the identification of the different plaque components. This may allow the identification of the vulnerable plaques before they rupture and may provide a way to target pharmacological intervention to reduce or prevent cardiovascular disease.

5 510 Circulation August 1, 2000 Acknowledgments This study was supported in part by a Radiological Society of North America seed grant (Dr Fayad) and NIH grants P50-HL and R01-HL We acknowledge the help of Karen Metroka, Stella Palencia, and Mary Ann Whelan-Gales in patient selection and recruitment. We thank Paul Wisdom and John Abela for help in MRI. References 1. Falk E, Shah PK, Fuster V. Coronary plaque disruption. Circulation. 1995;92: Fuster V, Fayad ZA, Badimon JJ. Acute coronary syndromes: biology. Lancet. 1999;353(suppl 2):SII5 SII9. 3. Davies MJ. Stability and instability: two faces of coronary atherosclerosis: the Paul Dudley White Lecture, Circulation. 1996;94: Glagov S, Weisenberg E, Zarins CK, et al. Compensatory enlargement of human atherosclerotic coronary arteries. N Engl J Med. 1987;316: Ge J, Chirillo F, Schwedtmann J, et al. Screening of ruptured plaques in patients with coronary artery disease by intravascular ultrasound. Heart. 1999;81: Callister TQ, Raggi P, Cooil B, et al. Effect of HMG-CoA reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography. N Engl J Med. 1998;339: Uchida Y, Nakamura F, Tomaru T, et al. Prediction of acute coronary syndromes by percutaneous coronary angioscopy in patients with stable angina. Am Heart J. 1995;130: Skinner MP, Yuan C, Mitsumori L, et al. Serial magnetic resonance imaging of experimental atherosclerosis detects lesion fine structure, progression and complications in vivo. Nat Med. 1995;1: Fayad ZA, Fallon JT, Shinnar M, et al. Noninvasive in vivo highresolution magnetic resonance imaging of atherosclerotic lesions in genetically engineered mice. Circulation. 1998;98: Yuan C, Beach KW, Smith LH Jr, et al. Measurement of atherosclerotic carotid plaque size in vivo using high resolution magnetic resonance imaging. Circulation. 1998;98: Toussaint JF, LaMuraglia GM, Southern JF, et al. Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo. Circulation. 1996;94: Fayad ZA, Tamana N, Badimon JJ, et al. In-vivo MR characterization of plaques in the thoracic aorta. Circulation. 1998;98(suppl I):I-515. Abstract. 13. Worthley SG, Helft G, Fuster V, et al. High resolution ex vivo magnetic resonance imaging of in situ coronary and aortic atherosclerosis plaque in a porcine model. Atherosclerosis. 2000;150: Manning WJ, Li W, Edelman RR. A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Engl J Med. 1993;328: Slavin GS, Riederer SJ, Ehman RL. Two-dimensional multishot echoplanar coronary MR angiography. Magn Reson Med. 1998;40: Meyer CH, Hu BS, Nishimura DG, et al. Fast spiral coronary artery imaging. Magn Reson Med. 1992;28: Jara H, Yu BC, Caruthers SD, et al. Voxel sensitivity function description of flow-induced signal loss in MR imaging: implications for black-blood MR angiography with turbo spin-echo sequences. Magn Reson Med. 1999;41: Alexander AL, Buswell HR, Sun Y, et al. Intracranial black-blood MR angiography with high-resolution 3D fast spin echo. Magn Reson Med. 1998;40: Edelman RR, Mattle HP, Wallner B, et al. Extracranial carotid arteries: evaluation with black blood MR angiography. Radiology. 1990;177: Schmalbrock P, Hacker VA, Rao A. Three-dimensional steady-state MR angiography of the lower extremities. J Magn Reson Imaging. 1994;4: Le Roux P, Gilles RJ, McKinnon GC, et al. Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging. J Magn Reson Imaging. 1998;8: Edelman RR, Chien D, Kim D. Fast selective black blood MR imaging. Radiology. 1991;181: Simonetti OP, Finn JP, White RD, et al. Black blood T2-weighted inversion-recovery MR imaging of the heart. Radiology. 1996;199: Fayad ZA, Connick TJ, Axel L. An improved quadrature or phased-array coil for MR cardiac imaging. Magn Reson Med. 1995;34: Silver MS, Joseph RI, Hoult DI. Highly selective /2 and pulse generation. J Magn Res. 1984;59: Shinnar M, Eleff S, Subramanian H, et al. The synthesis of pulse sequences yielding arbitrary magnetization vectors. Magn Reson Med. 1989;12: Alsop DC. The sensitivity of low flip angle RARE imaging. Magn Reson Med. 1997;37: Le Roux P, Hinks RS. Stabilization of echo amplitudes in FSE sequences. Magn Reson Med. 1993;30: Hennig J. Multiecho imaging sequences with low refocusing flip angles. J Magn Reson. 1988;78: Kuroda K, Oshio K, Mulkern RV, et al. Optimization of chemical shift selective suppression of fat. Magn Reson Med. 1998;40: Listerud J, Einstein S, Outwater E, et al. First principles of fast spin echo. Magn Reson Q. 1992;8: McPherson DD, Hiratzka LF, Lamberth WC, et al. Delineation of the extent of coronary atherosclerosis by high-frequency epicardial echocardiography. N Engl J Med. 1987;316: Potkin BN, Bartorelli AL, Gessert JM, et al. Coronary artery imaging with intravascular high-frequency ultrasound. Circulation. 1990;81: McPherson DD, Johnson MR, Alvarez NM, et al. Variable morphology of coronary atherosclerosis: characterization of atherosclerotic plaque and residual arterial lumen size and shape by epicardial echocardiography. J Am Coll Cardiol. 1992;19: Podesser BK, Neumann F, Neumann M, et al. Outer radius-wall thickness ratio, a postmortem quantitative histology in human coronary arteries. Acta Anat. 1998;163: Worthley SG, Helft G, Fuster V, et al. In vivo high-resolution MRI non-invasively defines coronary lesion size and composition in a porcine model. Circulation. 1999;100(suppl I):I-521. Abstract. 37. Luk-Pat GT, Gold GE, Olcott EW, et al. High-resolution threedimensional in vivo imaging of atherosclerotic plaque. Magn Reson Med. 1999;42: Du YP, Parker DL, Davis WL, et al. Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography. J Magn Reson Imaging. 1994;4: Gold GE, Pauly JM, Glover GH, et al. Characterization of atherosclerosis with a 1.5-T imaging system. J Magn Reson Imaging. 1993;3: Shinnar M, Fallon JT, Wehrli S, et al. The diagnostic accuracy of ex vivo magnetic resonance imaging for human atherosclerotic plaque characterization. Arterioscler Thromb Vasc Biol. 1999;19: Toussaint JF, Southern JF, Fuster V, et al. Water diffusion properties of human atherosclerosis and thrombosis measured by pulse field gradient nuclear magnetic resonance. Arterioscler Thromb Vasc Biol. 1997;17: Pachot-Clouard M, Vaufrey F, Darrasse L, et al. Magnetization transfer characteristics in atherosclerotic plaque components assessed by adapted binomial preparation pulses. Magma. 1998;7: Lin W, Abendschein DR, Haacke EM. Contrast-enhanced magnetic resonance angiography of carotid arterial wall in pigs. J Magn Reson Imaging. 1997;7: Martin AJ, Gotlieb AI, Henkelman RM. High-resolution MR imaging of human arteries. J Magn Reson Imaging. 1995;5: Yuan C, Murakami JW, Hayes CE, et al. Phased-array magnetic resonance imaging of the carotid artery bifurcation: preliminary results in healthy volunteers and a patient with atherosclerotic disease. J Magn Reson Imaging. 1995;5: Melhem ER, Jara H, Yucel EK. Black blood MR angiography using multislab three-dimensional TI-weighted turbo spin-echo technique: imaging of intracranial circulation. Am J Roentgenol. 1997;169: Ehman RL, Felmlee JP. Adaptive technique for high-definition MR imaging of moving structures. Radiology. 1989;173: Botnar RM, Stuber M, Danias PG, et al. Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation. 1999;99: Hochman JS, Phillips WJ, Ruggieri D, et al. The distribution of atherosclerotic lesions in the coronary arterial tree: relation to cardiac risk factors. Am Heart J. 1988;116:

MR Advance Techniques. Vascular Imaging. Class II

MR Advance Techniques. Vascular Imaging. Class II MR Advance Techniques Vascular Imaging Class II 1 Vascular Imaging There are several methods that can be used to evaluate the cardiovascular systems with the use of MRI. MRI will aloud to evaluate morphology

More information

Conventional coronary angiography frequently underestimates

Conventional coronary angiography frequently underestimates Noninvasive Coronary Vessel Wall and Plaque Imaging With Magnetic Resonance Imaging René M. Botnar, PhD; Matthias Stuber, PhD; Kraig V. Kissinger, BS, RT; Won Y. Kim, MD, PhD; Elmar Spuentrup, MD; Warren

More information

Matthias Stuber, PhD Associate Professor Division of MRI Research Johns Hopkins University Baltimore, MD

Matthias Stuber, PhD Associate Professor Division of MRI Research Johns Hopkins University Baltimore, MD Coronary Magnetic Resonance Imaging Matthias Stuber, PhD Associate Professor Division of MRI Research Johns Hopkins University Baltimore, MD The Need for MRI Background X-ray coronary angiograpy (gold

More information

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA 99. MRA Principles and Carotid MRA As described in Chapter 12, time of flight (TOF) magnetic resonance angiography (MRA) is commonly utilized in the evaluation of the circle of Willis. TOF MRA allows depiction

More information

Magnetic Resonance Angiography

Magnetic Resonance Angiography Magnetic Resonance Angiography 1 Magnetic Resonance Angiography exploits flow enhancement of GR sequences saturation of venous flow allows arterial visualization saturation of arterial flow allows venous

More information

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine Non Contrast MRA Mayil Krishnam Director, Cardiovascular and Thoracic Imaging University of California, Irvine No disclosures Non contrast MRA-Why? Limitations of CTA Radiation exposure Iodinated contrast

More information

RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE

RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE In Practice RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE By Atsuya Watanabe, MD, PhD, Director, Advanced Diagnostic Imaging Center and Associate Professor, Department of Orthopedic Surgery, Teikyo

More information

MR coronary artery imaging with 3D motion adapted gating (MAG) in comparison to a standard prospective navigator technique

MR coronary artery imaging with 3D motion adapted gating (MAG) in comparison to a standard prospective navigator technique Journal of Cardiovascular Magnetic Resonance (2005) 7, 793 797 Copyright D 2005 Taylor & Francis Inc. ISSN: 1097-6647 print / 1532-429X online DOI: 10.1080/10976640500287547 ANGIOGRAPHY MR coronary artery

More information

1Pulse sequences for non CE MRA

1Pulse sequences for non CE MRA MRI: Principles and Applications, Friday, 8.30 9.20 am Pulse sequences for non CE MRA S. I. Gonçalves, PhD Radiology Department University Hospital Coimbra Autumn Semester, 2011 1 Magnetic resonance angiography

More information

Real-Time Black-Blood MRI Using Spatial Presaturation

Real-Time Black-Blood MRI Using Spatial Presaturation JOURNAL OF MAGNETIC RESONANCE IMAGING 13:807 812 (2001) Technical Note Real-Time Black-Blood MRI Using Spatial Presaturation Krishna S. Nayak, Ph.D., 1 * Pedro A. Rivas, M.D., 2 John M. Pauly, Ph.D., 1

More information

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview CARDIAC MRI Dr Yang Faridah A. Aziz Department of Biomedical Imaging University of Malaya Medical Centre Cardiovascular Disease Diseases of the circulatory system, also called cardiovascular disease (CVD),

More information

Using Radial k-space Sampling and Steady-State Free Precession Imaging

Using Radial k-space Sampling and Steady-State Free Precession Imaging MRI of Coronary Vessel Walls Cardiac Imaging Original Research A C D E M N E U T R Y L I A M C A I G O F I N G Marcus Katoh 1 Elmar Spuentrup 1 Arno Buecker 1 Tobias Schaeffter 2 Matthias Stuber 3 Rolf

More information

Fulfilling the Promise

Fulfilling the Promise Fulfilling the Promise of Cardiac MR Non-contrast, free-breathing technique generates comprehensive evaluation of the coronary arteries By Maggie Fung, MR Cardiovascular Clinical Development Manager; Wei

More information

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03 Introduction Cardiac Imaging Modalities Arnaud Bistoquet 12/19/03 Coronary heart disease: the vessels that supply oxygen-carrying blood to the heart, become narrowed and unable to carry a normal amount

More information

Aortic Vessel Wall Imaging Using 3D Phase Sensitive Inversion Recovery in Children and Young Adults

Aortic Vessel Wall Imaging Using 3D Phase Sensitive Inversion Recovery in Children and Young Adults Aortic Vessel Wall Imaging Using 3D Phase Sensitive Inversion Recovery in Children and Young Adults Animesh Tandon, MD, MS 1,2, Tarique Hussain, MD, PhD 1,2, Andrew Tran, MD, MS 3, René M Botnar, PhD 4,

More information

MR Imaging of Atherosclerotic Plaques

MR Imaging of Atherosclerotic Plaques MR Imaging of Atherosclerotic Plaques Yeon Hyeon Choe, MD Department of Radiology, Samsung Medical Center, Sungkyunkwan University, Seoul MRI for Carotid Atheroma Excellent tissue contrast (fat, fibrous

More information

Clinical Applications

Clinical Applications C H A P T E R 16 Clinical Applications In selecting pulse sequences and measurement parameters for a specific application, MRI allows the user tremendous flexibility to produce variations in contrast between

More information

Objectives 8/17/2011. Challenges in Cardiac Imaging. Challenges in Cardiac Imaging. Basic Cardiac MRI Sequences

Objectives 8/17/2011. Challenges in Cardiac Imaging. Challenges in Cardiac Imaging. Basic Cardiac MRI Sequences 8/17/2011 Traditional Protocol Model for Tomographic Imaging Cardiac MRI Sequences and Protocols Frandics Chan, M.D., Ph.D. Stanford University Medical Center Interpretation Lucile Packard Children s Hospital

More information

Plaque Imaging: What It Can Tell Us. Kenneth Snyder, MD, PhD L Nelson Hopkins MD FACS Elad Levy MD MBA FAHA FACS Adnan Siddiqui MD PhD

Plaque Imaging: What It Can Tell Us. Kenneth Snyder, MD, PhD L Nelson Hopkins MD FACS Elad Levy MD MBA FAHA FACS Adnan Siddiqui MD PhD Plaque Imaging: What It Can Tell Us Kenneth Snyder, MD, PhD L Nelson Hopkins MD FACS Elad Levy MD MBA FAHA FACS Adnan Siddiqui MD PhD Buffalo Disclosure Information FINANCIAL DISCLOSURE: Research and consultant

More information

Coronary angiography is the standard way of visualizing

Coronary angiography is the standard way of visualizing Clinical Investigation and Reports Coronary Artery Fly-Through Using Electron Beam Computed Tomography Peter M.A. van Ooijen, MSc; Matthijs Oudkerk, MD, PhD; Robert J.M. van Geuns, MD; Benno J. Rensing,

More information

Raja Muthupillai, PhD. Department of Diagnostic and Interventional Radiology St. Luke s Episcopal Hospital. Research Support: Philips Healthcare

Raja Muthupillai, PhD. Department of Diagnostic and Interventional Radiology St. Luke s Episcopal Hospital. Research Support: Philips Healthcare 3D Cardiac Imaging Raja Muthupillai, PhD Department of Diagnostic and Interventional Radiology St. Luke s Episcopal Hospital Houston, TX Disclosures Research Support: Philips Healthcare This presentation

More information

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation for spiral flow imaging Joao L. A. Carvalho Previous talks Non-Cartesian reconstruction (2005) Spiral FVE (Spring 2006) Aortic flow Carotid flow Accelerated spiral FVE (Fall 2006) 2007? Department of Electrical

More information

Non-Contrast MRA. How and When 1996! Why Non-Contrast MRA? Angiography: What are our goals? Inflow Techniques Differences in excitation hx

Non-Contrast MRA. How and When 1996! Why Non-Contrast MRA? Angiography: What are our goals? Inflow Techniques Differences in excitation hx A major teaching hospital of Harvard Medical School Angiography: What are our goals? Non-Contrast MRA: How and When Neil M. Rofsky, M.D. Professor of Radiology, Harvard Medical School Director of MRI &

More information

Coronary MR angiography (MRA) is able to depict the

Coronary MR angiography (MRA) is able to depict the Improved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRA René M. Botnar, PhD; Matthias Stuber, PhD; Peter G. Danias, MD, PhD; Kraig V. Kissinger, BS, RT; Warren

More information

Functional Chest MRI in Children Hyun Woo Goo

Functional Chest MRI in Children Hyun Woo Goo Functional Chest MRI in Children Hyun Woo Goo Department of Radiology and Research Institute of Radiology Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea No ionizing radiation

More information

UK Biobank. Imaging modality Cardiovascular Magnetic Resonance (CMR) Version th Oct 2015

UK Biobank. Imaging modality Cardiovascular Magnetic Resonance (CMR) Version th Oct 2015 Imaging modality Cardiovascular Magnetic Resonance (CMR) Version 1.0 http://www.ukbiobank.ac.uk/ 30 th Oct 2015 This document details the procedure for the CMR scan performed at an Imaging assessment centre

More information

OCT. molecular imaging J Jpn Coll Angiol, 2008, 48: molecular imaging MRI positron-emission tomography PET IMT

OCT. molecular imaging J Jpn Coll Angiol, 2008, 48: molecular imaging MRI positron-emission tomography PET IMT 48 6 CT MRI PET OCT molecular imaging J Jpn Coll Angiol, 2008, 48: 456 461 atherosclerosis, imaging gold standard computed tomography CT magnetic resonance imaging MRI CT B intima media thickness IMT B

More information

MR Advance Techniques. Cardiac Imaging. Class IV

MR Advance Techniques. Cardiac Imaging. Class IV MR Advance Techniques Cardiac Imaging Class IV Heart The heart is a muscular organ responsible for pumping blood through the blood vessels by repeated, rhythmic contractions. Layers of the heart Endocardium

More information

Coronary Magnetic Resonance Angiography 1.5T Techniques

Coronary Magnetic Resonance Angiography 1.5T Techniques Coronary Magnetic Resonance Angiography 1.5T Techniques Matthias Stuber, PhD Johns Hopkins University, Baltimore MD Department of Radiology, Division of MR Research Address for Reprints and Correspondence:

More information

MR Advance Techniques. Cardiac Imaging. Class III

MR Advance Techniques. Cardiac Imaging. Class III MR Advance Techniques Cardiac Imaging Class III Black Blood Imaging & IR Blue= O2 poor blood Red=O2 rich blood Inversion pulses can produce black blood imaging in GRE pulse sequences. Specially on the

More information

Identification of Fibrous Cap Rupture With Magnetic Resonance Imaging Is Highly Associated With Recent Transient Ischemic Attack or Stroke

Identification of Fibrous Cap Rupture With Magnetic Resonance Imaging Is Highly Associated With Recent Transient Ischemic Attack or Stroke Identification of Fibrous Cap Rupture With Magnetic Resonance Imaging Is Highly Associated With Recent Transient Ischemic Attack or Stroke Chun Yuan, PhD; Shao-xiong Zhang, MD, PhD; Nayak L. Polissar,

More information

High-Resolution MR Angiography: Results in Diseased Arteries

High-Resolution MR Angiography: Results in Diseased Arteries IAGS Proceedings NEW IMAGING FOR NEW AND OLD DISEASES High-Resolution MR Angiography: Results in Diseased Arteries Peter Gonschior, M D, Ingo Pragst, M D, Gregor Valassis, M D, Claudia Vo g e l - Wiens,

More information

High Field MR of the Spine

High Field MR of the Spine Department of Radiology University of California San Diego 3T for MR Applications Advantages High Field MR of the Spine Increased signal-to-noise Better fat suppression Increased enhancement with gadolinium

More information

A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla

A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla Chinese Medical Journal 2009;122(18):2111-2116 2111 Original article A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla YANG Jian, WANG Wei, WANG Ya-rong, NIU Gang,

More information

ABSTRACT INTRODUCTION

ABSTRACT INTRODUCTION Journal of Cardiovascular Magnetic Resonance (2006) 8, 703 707 Copyright c 2006 Informa Healthcare ISSN: 1097-6647 print / 1532-429X online DOI: 10.1080/10976640600723706 Coronary Artery Magnetic Resonance

More information

Magnetic Resonance Imaging. Basics of MRI in practice. Generation of MR signal. Generation of MR signal. Spin echo imaging. Generation of MR signal

Magnetic Resonance Imaging. Basics of MRI in practice. Generation of MR signal. Generation of MR signal. Spin echo imaging. Generation of MR signal Magnetic Resonance Imaging Protons aligned with B0 magnetic filed Longitudinal magnetization - T1 relaxation Transverse magnetization - T2 relaxation Signal measured in the transverse plane Basics of MRI

More information

How I do it: Non Contrast-Enhanced MR Angiography (syngo NATIVE)

How I do it: Non Contrast-Enhanced MR Angiography (syngo NATIVE) Clinical How-I-do-it Cardiovascular How I do it: Non Contrast-Enhanced MR Angiography (syngo NATIVE) Manuela Rick, Nina Kaarmann, Peter Weale, Peter Schmitt Siemens Healthcare, Erlangen, Germany Introduction

More information

Current Status and Future Trends of MRI Technology for Carotid Plaque Imaging LI Rui*, CHEN Hui-Jun, YUAN Chun. *Biomedical Engineering Department, School of Medicine, Tsinghua University, Beijing 100084,

More information

The Low Sensitivity of Fluid-Attenuated Inversion-Recovery MR in the Detection of Multiple Sclerosis of the Spinal Cord

The Low Sensitivity of Fluid-Attenuated Inversion-Recovery MR in the Detection of Multiple Sclerosis of the Spinal Cord The Low Sensitivity of Fluid-Attenuated Inversion-Recovery MR in the Detection of Multiple Sclerosis of the Spinal Cord Mark D. Keiper, Robert I. Grossman, John C. Brunson, and Mitchell D. Schnall PURPOSE:

More information

Cardiac Imaging Tests

Cardiac Imaging Tests Cardiac Imaging Tests http://www.medpagetoday.com/upload/2010/11/15/23347.jpg Standard imaging tests include echocardiography, chest x-ray, CT, MRI, and various radionuclide techniques. Standard CT and

More information

Atherosclerosis is a chronic disease that affects medium

Atherosclerosis is a chronic disease that affects medium Classification of Human Carotid Atherosclerotic Lesions With In Vivo Multicontrast Magnetic Resonance Imaging Jian-Ming Cai, MD, PhD; Thomas S. Hatsukami, MD; Marina S. Ferguson, BS; Randy Small, BS; Nayak

More information

Influence of Velocity Encoding and Position of Image Plane in Patients with Aortic Valve Insufficiency Using 2D Phase Contrast MRI

Influence of Velocity Encoding and Position of Image Plane in Patients with Aortic Valve Insufficiency Using 2D Phase Contrast MRI Influence of Velocity Encoding and Position of Image Plane in Patients with Aortic Valve Insufficiency Using 2D Phase Contrast MRI M. Sc. Thesis Frida Svensson gussvefrh@student.gu.se Supervisors: Kerstin

More information

Analysis of Residual Coronary Artery Motion for Breath Hold and Navigator Approaches Using Real-Time Coronary MRI

Analysis of Residual Coronary Artery Motion for Breath Hold and Navigator Approaches Using Real-Time Coronary MRI Magnetic Resonance in Medicine 55:612 618 (2006) Analysis of Residual Coronary Artery Motion for Breath Hold and Navigator Approaches Using Real-Time Coronary MRI R. W. Fischer, 1,2 R. M. Botnar, 1,3 K.

More information

Scan Reproducibility of Magnetic Resonance Imaging Assessment of Aortic Atherosclerosis Burden

Scan Reproducibility of Magnetic Resonance Imaging Assessment of Aortic Atherosclerosis Burden Journal of Cardiovascular Magnetic Resonance, 3(4), 331 338 (2001) Scan Reproducibility of Magnetic Resonance Imaging Assessment of Aortic Atherosclerosis Burden Stephen K. Chan, 1 Farouc A. Jaffer, 1,3

More information

General Cardiovascular Magnetic Resonance Imaging

General Cardiovascular Magnetic Resonance Imaging 2 General Cardiovascular Magnetic Resonance Imaging 19 Peter G. Danias, Cardiovascular MRI: 150 Multiple-Choice Questions and Answers Humana Press 2008 20 Cardiovascular MRI: 150 Multiple-Choice Questions

More information

ARTICLE IN PRESS. Available online at Magnetic Resonance Imaging xx (2008) xxx xxx

ARTICLE IN PRESS. Available online at   Magnetic Resonance Imaging xx (2008) xxx xxx Available online at www.sciencedirect.com Magnetic Resonance Imaging xx (2008) xxx xxx An optimized 3D inversion recovery prepared fast spoiled gradient recalled sequence for carotid plaque hemorrhage

More information

Usefulness of the Navigator-echo triggering Technique for Free-Breathing 3D MRCP

Usefulness of the Navigator-echo triggering Technique for Free-Breathing 3D MRCP Usefulness of the Navigator-echo triggering Technique for Free-Breathing 3D MRCP Poster No.: C-1257 Congress: ECR 2012 Type: Scientific Exhibit Authors: K. Matsunaga, G. Ogasawara, K. Fujii, T. Irie, T.

More information

Speed, Comfort and Quality with NeuroDrive

Speed, Comfort and Quality with NeuroDrive Speed, Comfort and Quality with NeuroDrive Echelon Oval provides a broad range of capabilities supporting fast, accurate diagnosis of brain conditions and injuries. From anatomical depiction to vascular

More information

In Vivo 16-Slice, Multidetector-Row Computed Tomography for the Assessment of Experimental Atherosclerosis

In Vivo 16-Slice, Multidetector-Row Computed Tomography for the Assessment of Experimental Atherosclerosis In Vivo 16-Slice, Multidetector-Row Computed Tomography for the Assessment of Experimental Atherosclerosis Comparison With Magnetic Resonance Imaging and Histopathology Juan F. Viles-Gonzalez, MD; Michael

More information

Policy #: 222 Latest Review Date: March 2009

Policy #: 222 Latest Review Date: March 2009 Name of Policy: MRI Phase-Contrast Flow Measurement Policy #: 222 Latest Review Date: March 2009 Category: Radiology Policy Grade: Active Policy but no longer scheduled for regular literature reviews and

More information

Quantitative Imaging of Transmural Vasa Vasorum Distribution in Aortas of ApoE -/- /LDL -/- Double Knockout Mice using Nano-CT

Quantitative Imaging of Transmural Vasa Vasorum Distribution in Aortas of ApoE -/- /LDL -/- Double Knockout Mice using Nano-CT Quantitative Imaging of Transmural Vasa Vasorum Distribution in Aortas of ApoE -/- /LDL -/- Double Knockout Mice using Nano-CT M. Kampschulte 1, M.D.; A. Brinkmann 1, M.D.; P. Stieger 4, M.D.; D.G. Sedding

More information

IVUS Virtual Histology. Listening through Walls D. Geoffrey Vince, PhD The Cleveland Clinic Foundation

IVUS Virtual Histology. Listening through Walls D. Geoffrey Vince, PhD The Cleveland Clinic Foundation IVUS Virtual Histology Listening through Walls D. Geoffrey Vince, PhD Disclosure VH is licenced to Volcano Therapeutics Grant funding from Pfizer, Inc. Grant funding from Boston-Scientific Most Myocardial

More information

Anatomical and Functional MRI of the Pancreas

Anatomical and Functional MRI of the Pancreas Anatomical and Functional MRI of the Pancreas MA Bali, MD, T Metens, PhD Erasme Hospital Free University of Brussels Belgium mbali@ulb.ac.be Introduction The use of MRI to investigate the pancreas has

More information

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital Coronary Artery Imaging Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital Larger array : cover scan area Detector size : spatial resolution Rotation speed : scan time Retrospective

More information

Evaluation of Carotid Vessels and Vertebral Artery in Stroke Patients with Color Doppler Ultrasound and MR Angiography

Evaluation of Carotid Vessels and Vertebral Artery in Stroke Patients with Color Doppler Ultrasound and MR Angiography Evaluation of Carotid Vessels and Vertebral Artery in Stroke Patients with Color Doppler Ultrasound and MR Angiography Dr. Pramod Shaha 1, Dr. Vinay Raj R 2, Dr. (Brig) K. Sahoo 3 Abstract: Aim & Objectives:

More information

MRI protocol for post-repaired TOF

MRI protocol for post-repaired TOF 2012 NASCI MRI protocol for post-repaired TOF Taylor Chung, M.D. Associate Director, Body and Cardiovascular Imaging Department of Diagnostic Imaging Children s Hospital & Research Center Oakland Oakland,

More information

Sensitivity and Specificity in Detection of Labral Tears with 3.0-T MRI of the Shoulder

Sensitivity and Specificity in Detection of Labral Tears with 3.0-T MRI of the Shoulder Magee and Williams MRI for Detection of Labral Tears Musculoskeletal Imaging Clinical Observations C M E D E N T U R I C L I M G I N G JR 2006; 187:1448 1452 0361 803X/06/1876 1448 merican Roentgen Ray

More information

Multiplane Magnetic Resonance Imaging of the Heart and Major Vessels:

Multiplane Magnetic Resonance Imaging of the Heart and Major Vessels: 661 Charles B. Higgins1 David Stark Michael McNamara Peter Lanzer Lawrence E. Crooks Leon Kaufman Received October 25, 1983; accepted after revision January 5, 1984. This work was supported in part by

More information

Fully Refocused Gradient Recalled Echo (FRGRE): Factors Affecting Flow and Motion Sensitivity in Cardiac MRI

Fully Refocused Gradient Recalled Echo (FRGRE): Factors Affecting Flow and Motion Sensitivity in Cardiac MRI Journal of Cardiovascular Magnetic Resonance w, 4(2), 211 222 (2002) METHODS Fully Refocused Gradient Recalled Echo (FRGRE): Factors Affecting Flow and Motion Sensitivity in Cardiac MRI Laurie B. Hildebrand

More information

Identifying patients at risk: novel diagnostic techniques

Identifying patients at risk: novel diagnostic techniques European Heart Journal Supplements (2004) 6 (Supplement C), C15 C20 Identifying patients at risk: novel diagnostic techniques Department of Cardiology, The Cleveland Clinic Foundation, Cleveland, OH, USA

More information

Invasive Coronary Imaging Modalities for Vulnerable Plaque Detection

Invasive Coronary Imaging Modalities for Vulnerable Plaque Detection Invasive Coronary Imaging Modalities for Vulnerable Plaque Detection Gary S. Mintz, MD Cardiovascular Research Foundation New York, NY Greyscale IVUS studies have shown Plaque ruptures do not occur randomly

More information

Spiral Coronary Angiography Using a Blood Pool Agent

Spiral Coronary Angiography Using a Blood Pool Agent JOURNAL OF MAGNETIC RESONANCE IMAGING 22:213 218 (2005) Original Research Spiral Coronary Angiography Using a Blood Pool Agent Steffen Ringgaard, PhD, 1 * Michael Pedersen, PhD, 1 Jonas Rickers, MD, 1,2

More information

Perspectives of new imaging techniques for patients with known or suspected coronary artery disease

Perspectives of new imaging techniques for patients with known or suspected coronary artery disease Perspectives of new imaging techniques for patients with known or suspected coronary artery disease Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands Correspondence: Jeroen

More information

Chapter 43 Noninvasive Coronary Plaque Imaging

Chapter 43 Noninvasive Coronary Plaque Imaging hapter 43 Noninvasive oronary Plaque Imaging NIRUDH KOHLI The goal of coronary imaging is to define the extent of luminal narrowing as well as composition of an atherosclerotic plaque to facilitate appropriate

More information

MSRS 6473 Vascular Noninvasive Imaging Procedures

MSRS 6473 Vascular Noninvasive Imaging Procedures MSRS 6473 Vascular Noninvasive Imaging Procedures Rex T. Christensen MHA RT (R) (MR) (CT) (ARRT) CIIP Basic Physics Equipment Cardiac Positioning Perfusion Pathology MRI 1 Animal Magnetism MRI Basic Physics

More information

8/4/2016. MRI for Radiotherapy: MRI Basics. Nuclear Magnetic Resonance. Nuclear Magnetic Resonance. Wilson Miller

8/4/2016. MRI for Radiotherapy: MRI Basics. Nuclear Magnetic Resonance. Nuclear Magnetic Resonance. Wilson Miller MRI for Radiotherap: MRI asics Wilson Miller Universit of Virginia Department of Radiolog & Medical Imaging AAPM 2016 August 4, 2016 Nuclear Magnetic Resonance Magnetic resonance images are created using

More information

6/23/2009. Inversion Recovery (IR) Techniques and Applications. Variations of IR Technique. STIR, FLAIR, TI and TI Null. Applications of IR

6/23/2009. Inversion Recovery (IR) Techniques and Applications. Variations of IR Technique. STIR, FLAIR, TI and TI Null. Applications of IR The Anatomy of Basic R Pulse Sequences Inversion Recovery () Techniques and Applications Chen Lin, PhD Indiana University School of edicine & Clarian Health Partners agnetization Preparation Section Chemical

More information

A Magnetic Resonance Imaging Method for

A Magnetic Resonance Imaging Method for Journal of Cardiovascular Magnetic Resonance, 1(1), 59-64 (1999) INVITED PAPER Use of MRI in ASD Asessment A Magnetic Resonance Imaging Method for Evaluating Atrial Septa1 Defects Godtfred Holmvang Cardiac

More information

Department of Radiology University of California San Diego. MR Angiography. Techniques & Applications. John R. Hesselink, M.D.

Department of Radiology University of California San Diego. MR Angiography. Techniques & Applications. John R. Hesselink, M.D. Department of Radiology University of California San Diego MR Angiography Techniques & Applications John R. Hesselink, M.D. Vascular Imaging Arterial flow void Flow enhancement Gadolinium enhancement Vascular

More information

High-Sensitivity Coil Array for Head and Neck Imaging: Technical Note

High-Sensitivity Coil Array for Head and Neck Imaging: Technical Note AJNR Am J Neuroradiol 22:1881 1886, November/December 2001 Technical Note High-Sensitivity Coil Array for Head and Neck Imaging: Technical Note Roland G. Henry, Nancy J. Fischbein, William P. Dillon, Daniel

More information

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor Cardiothoracic Radiology Disclosure I have no disclosure pertinent to this presentation.

More information

How to Learn MRI An Illustrated Workbook

How to Learn MRI An Illustrated Workbook How to Learn MRI An Illustrated Workbook Exercise 8: Cine Imaging of the Heart Teaching Points: How to do cardiac gating? What is Steady State Free Precession (SSFP)? What are the basic cardiac views and

More information

Extracranial Carotid Arteries: Evaluation with Black Blood MR Angiography

Extracranial Carotid Arteries: Evaluation with Black Blood MR Angiography Robert R. Edelman, MD #{149} Heinrich P. Mattle, MD #{149} Bernd Wallner, MD #{149} Richard Bajakian, MD #{149} Jonathan Kleefield, MD #{149} Craig Kent, MD #{149} John J. Skillman, MD Jeffrey B. Mendel,

More information

Fat Suppression in the Abdomen

Fat Suppression in the Abdomen Clinical How I do it? Fat Suppression in the Abdomen Wilhelm Horger Siemens Medical Solutions, Erlangen, Germany Introduction Due to the different chemical environment, hydrogen nuclei in - and in -tissue

More information

Validation of Automatically Classified Magnetic Resonance Images for Carotid Plaque Compositional Analysis

Validation of Automatically Classified Magnetic Resonance Images for Carotid Plaque Compositional Analysis Validation of Automatically Classified Magnetic Resonance Images for Carotid Plaque Compositional Analysis Sharon E. Clarke, MD, PhD; Vadim Beletsky, MD; Robert R. Hammond, MD; Robert A. Hegele, MD; Brian

More information

Cervical Spine: Three-dimensional Fast Spin-Echo MR Imaging Improved Recovery of Longitudinal Magnetization with Driven Equilibrium Pulse 1

Cervical Spine: Three-dimensional Fast Spin-Echo MR Imaging Improved Recovery of Longitudinal Magnetization with Driven Equilibrium Pulse 1 Elias R. Melhem, MD Ryuta Itoh, MD, PhD Paul J. M. Folkers, PhD Index terms: Magnetic resonance (MR), technology, 34.121419 Spinal cord, MR, 341.121419 Spine, MR, 34.121419 Radiology 2001; 218:283 288

More information

Cardiac MRI in ACHD What We. ACHD Patients

Cardiac MRI in ACHD What We. ACHD Patients Cardiac MRI in ACHD What We Have Learned to Apply to ACHD Patients Faris Al Mousily, MBChB, FAAC, FACC Consultant, Pediatric Cardiology, KFSH&RC/Jeddah Adjunct Faculty, Division of Pediatric Cardiology

More information

Detection of carotid plaque neovascularization with Superb Micro-Vascular Imaging

Detection of carotid plaque neovascularization with Superb Micro-Vascular Imaging Detection of carotid plaque neovascularization with Superb Micro-Vascular Imaging Yong Qiang Professor Ultrasonic Department, Beijing An-Zhen Hospital, Capital Medical University, China 1. Background Conventional

More information

Magnetization Preparation Sequences

Magnetization Preparation Sequences Magnetization Preparation Sequences Acquisition method may not give desired contrast Prep block adds contrast (and/or encoding) MP-RAGE = Magnetization prepared rapid acquisition with gradient echo (Mugler,

More information

Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution

Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution COMMUNICATIONS Magnetic Resonance in Medicine 44:511 515 (2000) Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution Eric C. Wong,* Wen-Ming Luh, and Thomas T. Liu A modified pulsed

More information

MR Tumor Staging for Treatment Decision in Case of Wilms Tumor

MR Tumor Staging for Treatment Decision in Case of Wilms Tumor MR Tumor Staging for Treatment Decision in Case of Wilms Tumor G. Schneider, M.D., Ph.D.; P. Fries, M.D. Dept. of Diagnostic and Interventional Radiology, Saarland University Hospital, Homburg/Saar, Germany

More information

Non-invasive Imaging of Carotid Artery Atherosclerosis

Non-invasive Imaging of Carotid Artery Atherosclerosis Non-invasive Imaging of Carotid Artery Atherosclerosis 최연현 성균관의대삼성서울병원영상의학과 Noninvasive Techniques US with Doppler CT MRI Ultrasonography Techniques of Carotid US US Anatomy (ICA vs ECA) Gray scale and

More information

Rapid Quantitation of High-Speed Flow Jets

Rapid Quantitation of High-Speed Flow Jets Rapid Quantitation of High-Speed Flow Jets Krishna S. Nayak, 1 * Bob S. Hu, 1,2 and Dwight G. Nishimura 1 Magnetic Resonance in Medicine 50:366 372 (2003) Flow jets containing velocities up to 5 7 m/s

More information

Isolated congenital coronary anomalies: Evaluation by multislice-ct or MRI

Isolated congenital coronary anomalies: Evaluation by multislice-ct or MRI Isolated congenital coronary anomalies: Evaluation by multislice-ct or MRI B.K. Velthuis, Dept. of Radiology UMC Utrecht, the Netherlands ESC 2010 Coronary artery anomalies CAA Uncommon 0.3-5% normal population

More information

Myocardial Viability: Breath-hold 3D MR Imaging of Delayed Hyperenhancement with Variable Sampling in Time 1

Myocardial Viability: Breath-hold 3D MR Imaging of Delayed Hyperenhancement with Variable Sampling in Time 1 Technical Developments Radiology Thomas K. F. Foo, PhD David W. Stanley, BS Ernesto Castillo, MD Carlos E. Rochitte, MD Yi Wang, MD João A. C. Lima, MD David A. Bluemke, MD, PhD Katherine C. Wu, MD Index

More information

Form 4: Coronary Evaluation

Form 4: Coronary Evaluation Form : Coronary Evaluation Print this Form t Started Date of Coronary Evaluation Coronary Evaluation Indication for Coronary Evaluation Check only one. Angio NOT DONE: n invasive test performed Followup

More information

Positive Remodeling of the Coronary Arteries Detected by Magnetic Resonance Imaging in an Asymptomatic Population

Positive Remodeling of the Coronary Arteries Detected by Magnetic Resonance Imaging in an Asymptomatic Population Journal of the American College of Cardiology Vol. 53, No. 18, 2009 2009 by the American College of Cardiology Foundation ISSN 0735-1097/09/$36.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2008.12.063

More information

Cardiovascular MR Imaging at 3 T: Opportunities, Challenges, and Solutions 1

Cardiovascular MR Imaging at 3 T: Opportunities, Challenges, and Solutions 1 TECHNICAL ADVANCEMENTS IN CARDIAC MR IMAGING 1612 Cardiovascular MR Imaging at 3 T: Opportunities, Challenges, and Solutions 1 Prabhakar Rajiah, MD, FRCR Michael A. Bolen, MD Abbreviations: BOLD = blood

More information

Coronary MRI: State-of-the-Art

Coronary MRI: State-of-the-Art Coronary MRI: State-of-the-Art Michael V. McConnell, MD, MSEE Associate Professor of Medicine and Electrical Engineering (by courtesy) Division of Cardiovascular Medicine, Stanford University School of

More information

MR Angiography in the evaluation of Lower Extremity Arterial Disease

MR Angiography in the evaluation of Lower Extremity Arterial Disease March 2001 MR Angiography in the evaluation of Lower Extremity Arterial Disease Ted Mau, Harvard Medical School Year III Objectives We will cover: Indications for Magnetic Resonance Angiography (MRA) Basic

More information

EAE Teaching Course. Magnetic Resonance Imaging. Competitive or Complementary? Sofia, Bulgaria, 5-7 April F.E. Rademakers

EAE Teaching Course. Magnetic Resonance Imaging. Competitive or Complementary? Sofia, Bulgaria, 5-7 April F.E. Rademakers EAE Teaching Course Magnetic Resonance Imaging Competitive or Complementary? Sofia, Bulgaria, 5-7 April 2012 F.E. Rademakers Complementary? Of Course N Engl J Med 2012;366:54-63 Clinical relevance Treatment

More information

Simultaneous Bright- and Black-Blood Whole-Heart MRI for Noncontrast Enhanced Coronary Lumen and Thrombus Visualization

Simultaneous Bright- and Black-Blood Whole-Heart MRI for Noncontrast Enhanced Coronary Lumen and Thrombus Visualization FULL PAPER Magnetic Resonance in Medicine 79:1460 1472 (2018) Simultaneous Bright- and Black-Blood Whole-Heart MRI for Noncontrast Enhanced Coronary Lumen and Thrombus Visualization Giulia Ginami, 1 *

More information

Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR Imaging

Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR Imaging Provläsningsexemplar / Preview TECHNICAL REPORT ISO/TR 16379 First edition 2014-03-01 Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR

More information

Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience

Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience Ximing Wang, M.D., Zhaoping Cheng, M.D., Dawei Wu, M.D., Lebin

More information

Cardiovascular Imaging

Cardiovascular Imaging Cardiovascular Imaging Cardiovascular Imaging Cardio and Vascular Imaging Vascularization / Angiogenesis Cardiovascular Imaging metabolic imaging of the heart myocardial perfusion imaging Cardiac CT Vascularization

More information

The Severity of Coronary Atherosclerosis at Sites of Plaque Rupture With Occlusive Thrombosis

The Severity of Coronary Atherosclerosis at Sites of Plaque Rupture With Occlusive Thrombosis 1138 MORPHOLOGIC STUDIES The Severity of Coronary Atherosclerosis at Sites of Plaque Rupture With Occlusive Thrombosis JIAN-HUA QIAO, MD, MICHAEL C. FISHBEIN, MD, FACC Los Angeles. California Atherosclerotic

More information

Methods. Yahya Paksoy, Bülent Oğuz Genç, and Emine Genç. AJNR Am J Neuroradiol 24: , August 2003

Methods. Yahya Paksoy, Bülent Oğuz Genç, and Emine Genç. AJNR Am J Neuroradiol 24: , August 2003 AJNR Am J Neuroradiol 24:1364 1368, August 2003 Retrograde Flow in the Left Inferior Petrosal Sinus and Blood Steal of the Cavernous Sinus Associated with Central Vein Stenosis: MR Angiographic Findings

More information

An Effect of Spatial Filtering in Visualization of Coronary Arteries Imaging.

An Effect of Spatial Filtering in Visualization of Coronary Arteries Imaging. An Effect of Spatial Filtering in Visualization of Coronary Arteries Imaging. Dr. P.S. Hiremath1, Mr. Kodge B.G.2 1. Professor & Chairman, Department of Computer Sci. Gulbarga University, Gulbarga. State:

More information

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography 16-MDCT Coronary Angiography Shim et al. 16-MDCT Coronary Angiography Sung Shine Shim 1 Yookyung Kim Soo Mee Lim Received December 1, 2003; accepted after revision June 1, 2004. 1 All authors: Department

More information