XEMEX IABP Balloon Plus
|
|
- Rodney Singleton
- 5 years ago
- Views:
Transcription
1 XEMEX IABP Balloon Plus Ordering information Balloon Volume Catheter O.D. Balloon Length Balloon Diameter Recommended Patient Height BPGL57 (E) 5mL 18mm 15cm 11 BPGL7 (E) cm 11 5 BPGL57 (E) 165cm 5 5 BPGL8 (E) 155cm 5 1 BPGL58 (E) 1mm 15.1mm cm BPGL8 (E) 15.1mm 165cm 5 5 BPGL58-SH (E)* 16mm 15cm 9 BPGL8-SH(E)* 18mm 16cm 5 *Short Balloon Type **Refer to the figure only as a guide. Please select product by confirming balloon length and diameter. Manufactured by: 1-6- Marunouchi, Chiyoda-ku, Tokyo 1, Japan TEL: FAX: XEMEX is the brand by ZEON MEDICAL INC. Copyright 17 ZEON MEDICAL INC. All rights reserved. Ver. July 17 (E)CX- 717(IM5) Agent: **
2 Techn nology from JA APAN Eterna al pursu uit of safety and crea atiivity Measurement of Aorta and analysis of IABP balloon sizes Development of New Concept Balloon Each size below was measured via images of CT (Figure 1) No. of patients: 1 patients on whom contrast-enhanced CT was performed XEMEX IABP Balloon Plus 8F Short Balloon Reference and citation: Use of 8F Short Balloons at Our Facility by Kazuya Hirata, Department of ME, Hokkaido Social Insurance Hospital, Japan Three keys for patient-oriented catheter Measured Items 1. Distance between left subclavian artery and aorta below renal artery. Minor diameter of descending aorta. Minor diameter of subphrenic aorta. Minor diameter of aorta below renal artery XEMEX product development in close cooperation with medical sites IABP Augmentation Efficacy Catheter Migration -Balloon diameter is increased by mm for better augmentation -Nylon catheter shaft performs high durability The experiment proved that XEMEX Short IABP balloon catheter was remarkable in augmentation effect compared to Normal IABP. The experiment proved that XEMEX Short IABP is superior to those of competitors as well as XEMEX conventional balloon. (mmhg msec) Figure : Results of measurement 1. XEMEX 8F Short Figure 1 : Sites of measurement Measured tip positioning after 1-hour driving in the mock circuit n=1 16. In the analysis of balloon diameter, the diameter of the aortic artery was larger than the balloon diameter of the Shor t IABP at the site of the positioned IABP catheter. However, since the descending aorta begins to follow a tortuous course nearby the subphrenic region and there is a risk of the balloon contacting the vessel wall at the tortuous points, the augmentation level should be set properly by watching the balloon pressure patterns in order not to expose the vascular wall to excessive stress. Feature Measurement of augmentation efficacy, short balloon and normal balloon The result shows that the aortic vessel tends to become smaller below the renal ar ter y and appears calcification and intimal hypertrophy in approximately % of the patients. Considering IAB balloon length and balloon diameter, when 8F Normal IABP catheter was used in these patients, the catheter was positioned nearby the area below the renal artery in some cases, which raises the risk of balloon rupture and other complications. To ensure safety in this case, use of 8F Short IABP catheter seemed to be superior. (Figure ) 8F Short Balloon Prevent renal arterial occlusion High augmentation performance Reduce balloon leak risk Company A 8F male female total Company B 8F 1.5 XEMEX 8F Normal Number of patients: 6 1 Mean age (years) Mean height (cm) Distance from left subclavicular artery to aorta below renal artery Minor diameter of descending aorta Minor diameter of subphrenic aorta Minor diameter of aorta below renal artery Vessel mm Vessel 5mm Vessel mm Vessel 5mm - * Short balloon is only for test trial and not for sale *Comparison of Length ( IABP) Balloon length is reduced by 5% of conventional balloon catheter Better pushability, better trackability and less risk of renal arterial occlusion Data logger Pressure transducer IAB Short Thermo stat (7 ) PC VAD Cushion tank for pressure adjustment. lumen for blood pressure measurement Calcification or tunica intima thickening seen in about % of cases Normal IABP Short IABP Mock circuit for the experiment Normal Pseudo Blood : 5% glycerin solution, warmed to 7 (viscosity cps) Blood Pressure : 1/5 mmhg, heart rate 1bpm Console : XEMEX IABP Console 98 Assist ratio : 1: Data collected and analyzed by Hokkaido Social Insurance Hospital, Japan
3 Techn nology from JA APAN Eterna al pursu uit of safety and crea atiivity Measurement of Aorta and analysis of IABP balloon sizes Development of New Concept Balloon Each size below was measured via images of CT (Figure 1) No. of patients: 1 patients on whom contrast-enhanced CT was performed XEMEX IABP Balloon Plus 8F Short Balloon Reference and citation: Use of 8F Short Balloons at Our Facility by Kazuya Hirata, Department of ME, Hokkaido Social Insurance Hospital, Japan Three keys for patient-oriented catheter Measured Items 1. Distance between left subclavian artery and aorta below renal artery. Minor diameter of descending aorta. Minor diameter of subphrenic aorta. Minor diameter of aorta below renal artery XEMEX product development in close cooperation with medical sites IABP Augmentation Efficacy Catheter Migration -Balloon diameter is increased by mm for better augmentation -Nylon catheter shaft performs high durability The experiment proved that XEMEX Short IABP balloon catheter was remarkable in augmentation effect compared to Normal IABP. The experiment proved that XEMEX Short IABP is superior to those of competitors as well as XEMEX conventional balloon. (mmhg msec) Figure : Results of measurement 1. XEMEX 8F Short Figure 1 : Sites of measurement Measured tip positioning after 1-hour driving in the mock circuit n=1 16. In the analysis of balloon diameter, the diameter of the aortic artery was larger than the balloon diameter of the Shor t IABP at the site of the positioned IABP catheter. However, since the descending aorta begins to follow a tortuous course nearby the subphrenic region and there is a risk of the balloon contacting the vessel wall at the tortuous points, the augmentation level should be set properly by watching the balloon pressure patterns in order not to expose the vascular wall to excessive stress. Feature Measurement of augmentation efficacy, short balloon and normal balloon The result shows that the aortic vessel tends to become smaller below the renal ar ter y and appears calcification and intimal hypertrophy in approximately % of the patients. Considering IAB balloon length and balloon diameter, when 8F Normal IABP catheter was used in these patients, the catheter was positioned nearby the area below the renal artery in some cases, which raises the risk of balloon rupture and other complications. To ensure safety in this case, use of 8F Short IABP catheter seemed to be superior. (Figure ) 8F Short Balloon Prevent renal arterial occlusion High augmentation performance Reduce balloon leak risk Company A 8F male female total Company B 8F 1.5 XEMEX 8F Normal Number of patients: 6 1 Mean age (years) Mean height (cm) Distance from left subclavicular artery to aorta below renal artery Minor diameter of descending aorta Minor diameter of subphrenic aorta Minor diameter of aorta below renal artery Vessel mm Vessel 5mm Vessel mm Vessel 5mm - * Short balloon is only for test trial and not for sale *Comparison of Length ( IABP) Balloon length is reduced by 5% of conventional balloon catheter Better pushability, better trackability and less risk of renal arterial occlusion Data logger Pressure transducer IAB Short Thermo stat (7 ) PC VAD Cushion tank for pressure adjustment. lumen for blood pressure measurement Calcification or tunica intima thickening seen in about % of cases Normal IABP Short IABP Mock circuit for the experiment Normal Pseudo Blood : 5% glycerin solution, warmed to 7 (viscosity cps) Blood Pressure : 1/5 mmhg, heart rate 1bpm Console : XEMEX IABP Console 98 Assist ratio : 1: Data collected and analyzed by Hokkaido Social Insurance Hospital, Japan
4 Techn nology from JA APAN Eterna al pursu uit of safety and crea atiivity Advantage Technology 1. Inner Stopper 1. High Level Balloon and Catheter Positioning Stability Competitor Keeps proper position of after catheter placement Strengthened adhesion of inner and outer tubes for stable pumping (patent pending) Integrated double lumen structure for superior response performance and durability of the catheter Area from celiac artery to renal arteries 8F Short Balloon Migrated catheter position by blood heat softening. High Durability of Catheter Shaft Superior stability of Nylon catheter shaft Prevents catheter from blood heat softening and damage of vessel walls Stiffer shaft provides super trackability to catherter 1. Stiff nylon catheter shaft. Three-level-diameter shaft structure Measurement of balloon position migration after 1-hour driving in the mock vessel Large helium gas lumen provides better response performance with small size catheters Kink-resistant performance improved by reliable inner and outer shaft anchoring Helium gas Lumen. Three-Level-Diameter -1 - New XEMEX 8F Company A 8F - 5. Sheath Introducer -1 New XEMEX 7F Sheath tip insertion resistance. Pumping Response Performance (Newton) 8 7 XEMEX 7F XEMEX 8F 6 5 Pumping response performance is ensured by: Tapered structure toward proximal of outer shaft provides catheter shaft durability Succeeded in higher response performance by enlargement of helium gas lumen of outer shaft outside of the body Less gap between sheath and dilator Feature. Integrated Double Lumen Structure High Balloon position stability: 1. Double lumen structure with large helium gas lumen. Three-level-diameter catheter shaft. Inner stopper anchoring Company C 8F Measurement of total inflation and deflation time (msec) (msec) 5 ZEON MEDICAL s processing technology realized: Smooth transition of diameter gap Less insertion resistance Increased intensity Prevention of distortion or deformation Excellence trackability of dilator tip to GW Downsized dilator tip has increased: Tip flexibility and trackability to the guide wire Prevention of damage to the vessel wall 6. Soft tip of catheter prevents unintentional vessel damage New XEMEX 7F New XEMEX 8F Company A 8F Sophisticated taper shape and soft material for catheter tip 5
5 Techn nology from JA APAN Eterna al pursu uit of safety and crea atiivity Advantage Technology 1. Inner Stopper 1. High Level Balloon and Catheter Positioning Stability Competitor Keeps proper position of after catheter placement Strengthened adhesion of inner and outer tubes for stable pumping (patent pending) Integrated double lumen structure for superior response performance and durability of the catheter Area from celiac artery to renal arteries 8F Short Balloon Migrated catheter position by blood heat softening. High Durability of Catheter Shaft Superior stability of Nylon catheter shaft Prevents catheter from blood heat softening and damage of vessel walls Stiffer shaft provides super trackability to catherter 1. Stiff nylon catheter shaft. Three-level-diameter shaft structure Measurement of balloon position migration after 1-hour driving in the mock vessel Large helium gas lumen provides better response performance with small size catheters Kink-resistant performance improved by reliable inner and outer shaft anchoring Helium gas Lumen. Three-Level-Diameter -1 - New XEMEX 8F Company A 8F - 5. Sheath Introducer -1 New XEMEX 7F Sheath tip insertion resistance. Pumping Response Performance (Newton) 8 7 XEMEX 7F XEMEX 8F 6 5 Pumping response performance is ensured by: Tapered structure toward proximal of outer shaft provides catheter shaft durability Succeeded in higher response performance by enlargement of helium gas lumen of outer shaft outside of the body Less gap between sheath and dilator Feature. Integrated Double Lumen Structure High Balloon position stability: 1. Double lumen structure with large helium gas lumen. Three-level-diameter catheter shaft. Inner stopper anchoring Company C 8F Measurement of total inflation and deflation time (msec) (msec) 5 ZEON MEDICAL s processing technology realized: Smooth transition of diameter gap Less insertion resistance Increased intensity Prevention of distortion or deformation Excellence trackability of dilator tip to GW Downsized dilator tip has increased: Tip flexibility and trackability to the guide wire Prevention of damage to the vessel wall 6. Soft tip of catheter prevents unintentional vessel damage New XEMEX 7F New XEMEX 8F Company A 8F Sophisticated taper shape and soft material for catheter tip 5
6 Technology from JAPAN Eternal pursuit of safety and creativity XEMEX IABP Balloon Plus Specification (insertion with sheath / sheath less ) Catheter Tray Balloon volume Catheter outer diameter Catheter type Inner diameter Catheter active length Balloon length Balloon diameter Catheter material Balloon material BPGL57 (E) BPGL7 (E) BPGL57 (E) 5mL.mm (7.F).71mm (.8inch).5mm (.inch).mm (7.F).71mm (.8inch).5mm (.inch).mm (7.F).71mm (.8inch).5mm (.inch) 651mm 681mm 71mm 18mm Outer tube: Nylon (antithrombogenic polyurethane coating) Inner tube: Special treated resin High-strength antithrombogenic polyurethane coating 5mL syringe, One-way valve for decompression Introducer Tray Sheath type Sheath active length Sheath inner diameter Standard type with hemostasis valve 17.5cm.mm J tip guide wire for balloon catheter insertion.5mm (. inch) X 15cm J tip guide wire for sheath introducer.88mm (.5 inch) X 8cm 18G Needle, Adapter for other manufacturer's driving consoles, Dilator (6F X 16.5cm), Blood pressure monitoring lines, -way stopcock Balloon volume Catheter outer diameter Catheter type Inner diameter Catheter active length Balloon length Balloon diameter Catheter material Balloon material Sheath type Sheath active length Sheath inner diameter Catheter Tray BPGL8 (E) BPGL58 (E) BPGL8 (E).66mm (8.F).88mm (.5inch).79mm (.1inch).66mm (8.F).88mm (.5inch).79mm (.1inch) 695mm 7mm 75mm 1mm 15.1mm 15.1mm Outer tube: Nylon (antithrombogenic polyurethane coating) Inner tube: Special treated resin High-strength antithrombogenic polyurethane coating 5mL syringe, One-way valve for decompression.66mm (8.F).88mm (.5inch).79mm (.1inch) Introducer Tray Standard type with hemostasis valve 17.5cm.7mm J tip guide wire for balloon catheter insertion.79mm (.1inch) X 15cm J tip guide wire for sheath introducer.88mm (.5 inch) X 8cm 18G Needle, Adapter for other manufacturer's driving consoles, Dilator (7F X 16.5cm), Blood pressure monitoring lines, -way stopcock 6
7 16mm/18mm Balloon volume Catheter outer diameter Catheter type Inner diameter Catheter active length Balloon length Balloon diameter Catheter material Balloon material Sheath type Sheath active length Sheath inner diameter Catheter Tray BPGL58-SH (E).66mm (8.F).88mm (.5 inch).79mm (.1 inch) 68mm 16mm Catheter Tray BPGL8-SH (E).66mm (8.F).88mm (.5 inch).79mm (.1 inch) 75mm 18mm Outer tube: Nylon(antithrombogenic polyurethane coating) Inner tube: Special treated resin High-strength antithrombogenic polyurethane coating 5mL syringe, One-way valve for decompression Introducer Tray Standard type with hemostasis valve 17.5cm.7mm J tip guide wire for balloon catheter insertion.79mm (.1inch) X 15cm J tip guide wire for sheath introducer.88mm (.5inch) X 8cm 18G Needle, Adapter for other manufacturer's driving consoles, Dilator (7F X 16.5cm), Blood pressure monitoring lines, -way stopcock Introducer Tray 8F Short Balloon Feature Driving Tube For MAQUET Console For TeleFlex Console Caution Please make sure to use catheter and introducer set packed in the same box. Please make sure to read the attached IFU when using the product. 7
8 XEMEX IABP Balloon Plus Ordering information Balloon Volume Catheter O.D. Balloon Length Balloon Diameter Recommended Patient Height BPGL57 (E) 5mL 18mm 15cm 11 BPGL7 (E) cm 11 5 BPGL57 (E) 165cm 5 5 BPGL8 (E) 155cm 5 1 BPGL58 (E) 1mm 15.1mm cm BPGL8 (E) 15.1mm 165cm 5 5 BPGL58-SH (E)* 16mm 15cm 9 BPGL8-SH(E)* 18mm 16cm 5 *Short Balloon Type **Refer to the figure only as a guide. Please select product by confirming balloon length and diameter. Manufactured by: 1-6- Marunouchi, Chiyoda-ku, Tokyo 1, Japan TEL: FAX: XEMEX is the brand by ZEON MEDICAL INC. Copyright 17 ZEON MEDICAL INC. All rights reserved. Ver. July 17 (E)CX- 717(IM5) Agent: **
LINEAR 7.5Fr. IAB Catheter
LINEAR 7.5Fr. IAB Catheter The LINEAR 7.5Fr. Catheter Easier to insert* Proprietary IAB Membrane provides better performance* Abrasion resistance improved 43%* Improved fatigue resistance* Immediate inflation
More informationLINEAR. 7.5Fr. IAB Catheter. This document is intended to provide information to an international audience outside of the US.
LINEAR 7.5Fr. IAB Catheter This document is intended to provide information to an international audience outside of the US. Maquet offers a range of convenient and innovative clinical solutions for counterpulsation
More informationHigh Flow Family. Short Term Dialysis Catheters. Dialysis
High Flow Family Short Term Dialysis Catheters Dialysis High Flow Triple Lumen 13.5 Fr Unique tip design, superior to the classic sidehole design: Clotting risk is considerably reduced Adhesion risk to
More informationER REBOA Catheter. Instructions for Use
ER REBOA Catheter Instructions for Use Prytime Medical Devices, Inc. 229 N. Main Street Boerne, TX 78006, USA feedback@prytimemedical.com www.prytimemedical.com US 1 210 340 0116 U.S. and Foreign Patents
More informationQuick Reference Guide
Quick Reference Guide Indications for Use The AFX Endovascular AAA System is indicated for endovascular treatment in patients with AAA. The devices are indicated for patients with suitable aneurysm morphology
More informationPTA Balloon Dilatation Catheter
PTA Balloon Dilatation Catheter March 2016 1/6(3214-0) Catalogue number Serial number Lot number Use by Do not reuse Do not resterilize Do not use if package is damaged Consult instructions for use Keep
More informationPTA Balloon Dilatation Catheter
PTA Balloon Dilatation Catheter 1/6(3211-0) February 2016 TIS-488-06272017 Catalogue number Serial number Lot number Use by Do not reuse Do not resterilize Do not use if package is damaged Consult instructions
More informationHLS Cannulae Solutions from tip to tip.
HLS Cannulae Solutions from tip to tip. This document is intended to provide information to an international audience outside of the US. 5 HLS cannulae HLS Cannulae Vessels access becomes easier. Maquet
More informationHLS Cannulae Solutions from tip to tip.
HLS Cannulae Solutions from tip to tip. This document is intended to provide information to an international audience outside of the US. 3 HLS cannulae Standard for single lumen cannulation. Smooth transition
More informationLINEAR. 7.5Fr. IAB CATHETER INSTRUCTIONS FOR USE. INSTRUCTIONS FOR USE LINEAR 7.5Fr. Intra-Aortic Balloon Catheter 1
LINEAR 7.5Fr. IAB CATHETER INSTRUCTIONS FOR USE Read this entire booklet before opening inner pack. INSTRUCTIONS FOR USE LINEAR 7.5Fr. Intra-Aortic Balloon Catheter 1 INTENDED USE The intra-aortic balloon
More informationSENSATION and CS300 Smaller meets faster. IABP System
SENSATION and CS300 Smaller meets faster IABP System Cardiac Assist SENSATION and CS300 3 Cardiac Assist SENSATION and CS300 5 Smaller The SENSATION 7Fr. Fiber-Optic IAB Catheter Faster The CS300 with
More informationSMOOTH VASCULAR ACCESS COMPARATIVE BENCH TOP RESULTS
SMOOTH VASCULAR ACCESS COMPARATIVE BENCH TOP RESULTS A NEW STANDARD FOR SMOOTH VASCULAR ACCESS NEEDLE PENETRATION FORCE Needle penetration was measured by the amount of force it took for the needle to
More informationCatheters and Wires. Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon
Catheters and Wires Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon Guidewires: Guidewires (solid wires navigated within the vascular system / extravascular tract) act
More informationThe Art of. Flow Restoration. Ikazuchi Zero. Semi-Compliant PTCA Balloon OVERVIEW CROSSABILITY LOW PROFILE CASE STUDY CODES
The Art of Flow Restoration Japan s Recognized PCI Technology For Both Everyday and Complex CTO Cases* Manufactured by Kaneka Corporation, one of Japan s leading providers of interventional devices. Now
More informationZenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up
Zenith Renu AAA Converter Graft Device Description Planning and Sizing Deployment Sequence Patient Follow-Up Device description: Device indications The Zenith Renu AAA Converter Graft with Z-Trak Introduction
More informationRECOMMENDED INSTRUCTIONS FOR USE
Rapid Exchange PTCA Dilatation Catheter RECOMMENDED INSTRUCTIONS FOR USE Available in diameters 1.25mm to 4.5mm and in lengths 09mm to 40mm Caution: This device should be used only by physicians trained
More informationAncillary Components with Z-Trak Introduction System
Ancillary Components with Z-Trak Introduction System Zenith Flex AAA Endovascular Graft Ancillary Components Converter Converters can be used to convert a bifurcated graft into an aortouniiliac graft if
More informationCP STENT. Large Diameter, Balloon Expandable Stent
CP STENT Large, Expandable CP STENT OPTIONS 12mm to Expansion 26mm to Expansion CP Matrix (number of zigs) 1.6 2.2 2.8 3.4 3.9 4.5 5 5.5 6 12 14 15 16 18 20 22 24 26 28 30 CP Details: CP is composed of
More informationPenumbra INTRACRANIAL ACCESS REDEFINED
Penumbra INTRACRANIAL ACCESS REDEFINED BENCHMARK Case Examples Stability & Compatibility Atraumatic Navigation Flow Diverter Delivery Pipeline BENCHMARK Stability Without Surpass Full distal shaft radiopacity
More informationCook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training
Cook Medical Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full-thickness,
More informationBifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully
Physician Training Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully supported by self-expanding z-stents H&L-B
More informationGlobal Myocardial Protection
Global Myocardial Protection Edwards offers a wide range of antegrade and retrograde cardioplegia products designed to promote global myocardial protection. Complete Antegrade/Retrograde Solutions Edwards
More informationGalt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family
Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family MICRO-INTRODUCERS Micro-Introducer Kits Galt s Micro-Introducer Kits with smooth transition,
More informationURGENT FIELD SAFETY NOTICE MEDICAL DEVICE FIELD CORRECTION Maquet/Datascope CARDIOSAVE Intra-Aortic Balloon Pump (IABP)
May 4, 2018 via [INSERT METHOD] URGENT FIELD SAFETY NOTICE MEDICAL DEVICE FIELD CORRECTION Maquet/Datascope CARDIOSAVE Intra-Aortic Balloon Pump (IABP) AFFECTED PRODUCT PART NUMBER DISTRIBUTION DATE Cardiosave
More informationMAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES
MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES PUSHING BOUNDARIES Terumo Interventional Systems is committed to your success with innovative procedural solutions and ongoing support for your most challenging
More information-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE
Stent Graft SOLUTIONS FOR VASCULAR DISEASE 1 PURE PERFORMANCE AND QUALITY: STENT GRAFT SYSTEMS BY JOTEC JOTEC is an innovation-oriented company with consistent focus on its core competencies: the development
More informationHLS CANNULAE SOLUTIONS FROM TIP TO TIP
HLS CANNULAE SOLUTIONS FROM TIP TO TIP HLS CANNULAE SETS VESSEL ACCESS BECOMES EASIER MAQUET THE GOLD STANDARD MAQUET is an international synonym for innovative and technological advances in operating
More informationIABP Timing & Fidelity. Pocket Reference Guide
IABP Timing & Fidelity Pocket Reference Guide Correct IABP Timing A = One complete cardiac cycle R B = Unassisted aortic end diastolic pressure P T C = Unassisted systolic pressure D = Diastolic augmentation
More informationAccess More Patients. Customize Each Seal.
Access More. Customize Each Seal. The Least Invasive Path Towards Proven Patency ULTRA LOW PROFILE TO EASE ADVANCEMENT The flexible, ultra-low 12F ID Ovation ix delivery system enables you to navigate
More informationAcute Therapy Systems. provencare Catheter Sets
Acute Therapy Systems provencare Catheter Sets Catheter Sets Contents provencare Catheter Sets 4 provencare Product Features and Accessories 6 provencare Single Lumen Catheter Sets 8 provencare Paediatric
More informationBalloon in Balloon (BIB )
Balloon in Balloon (BIB ) Stent Placement Catheter INSTRUCTIONS FOR USE CAUTION: FEDERAL (USA) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN. Read all instructions prior to use. Distributed
More informationi INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE
i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE Catalog 2017 i USER TIPS Easily navigate through the pages in our 2017 Cannula Catalog by using the mini-menu shown on upper right of each page. Navigate
More informationFROM THE EVERYDAY TO THE EXTRAORDINARY
FROM THE EVERYDAY TO THE EXTRAORDINARY Created with the collaboration of more than 250 physicians around the world, ENDURANT empowers you to create stronger outcomes for more patients, including those
More informationAdvancing Lives and the Delivery of Health Care. The High-Flow Port Designed for Apheresis
Advancing Lives and the Delivery of Health Care The High-Flow Port Designed for Apheresis Optimized for Long Device Life Bench Tested up to 1,000 Accesses 1 Bard is proud to introduce the first and only
More informationObesity, Scaring, Access in EVAR. Kiskinis D, Melas N, Ktenidis K. 1 st Department of Surgery Aristotle University of Thessaloniki, Greece
Obesity, Scaring, Access in EVAR Kiskinis D, Melas N, Ktenidis K. 1 st Department of Surgery Aristotle University of Thessaloniki, Greece Obesity Decreased radiolucency (visibility) Max weight load < 160
More informationThe SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use
The SplitWire Percutaneous Transluminal Angioplasty Scoring Device Instructions for Use Contents Contains one (1) SplitWire device. Sterile. Sterilized with ethylene oxide gas. Radiopaque. For single use
More informationNON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER
Page 1 of 5 NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER STERILE. SINGLE USE ONLY. Sterilized with ethylene oxide gas. Non pyrogenic. Do not resterilize. Do not use opened or damaged packages.
More informationMy idea on intimal tracking guide wire selection for Pop-BTK treatment
LINC 2017 Leipzig January 24-27, 2017 My idea on intimal tracking guide wire selection for Pop-BTK treatment Jos C. van den Berg, MD PhD Ospedale Regionale di Lugano, sede Civico Lugano University of Bern
More informationPolyurethane Dual Lumen Occlusion Catheter English Instructions for Use. Polyurethane Dual Lumen Occlusion Catheter
Polyurethane Dual Lumen Occlusion Catheter English Instructions for Use Polyurethane Dual Lumen Occlusion Catheter Polyurethane Dual Lumen Occlusion Catheter (Model Numbers 4F-2L-40, 4F-2L-80, 5F-2L-40,
More informationproduct catalogue Quality Results for life
product catalogue ET CATHETERS OPU NEEDLES Quality Results for life IUI CATHETERS OOCYTE RETRIEVAL NEEDLES NEEDLES oocyte retrieval needles Manufactured from steel of excellent quality, its triple cut
More informationLeMaitre Embolectomy Catheter
Instructions for Use - English Lemaitre Embolectomy Catheter (Model Numbers 1601-24, e1601-24, 1601-26, e1601-26, 1601-28, e1601-28, 1601-34, e1601-34, 1601-38, e1601-38, 1601-44, e1601-44, 1601-48, e1601-48,
More informationSection 6 Intra Aortic Balloon Pump
Section 6 Intra Aortic Balloon Pump The Intra Aortic Balloon Pump (IABP) The balloon is synthetic and is made for single use only. It is threaded into the aorta, usually via a femoral approach. The balloon
More informationAdvanced Innovation for Exceptional Performance
Advanced Innovation for Exceptional Performance longest BALLOON LENGTHS ON THE MARKET Bard Peripheral Vascular Ultraverse 014 300 mm Boston Scientific Coyote 220 mm Cordis SLEEK RX 220 mm Aviator Plus
More information1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER
Page 1 of 5 ASPIRATION CATHETER Carefully read all instructions prior to use, observe all warnings and precautions noted throughout these instructions. Failure to do so may result in complications. STERILE.
More informationProtecting Patients. Preserving Access.
MAHURKAR * Family of Acute Care Catheters Protecting Patients. Preserving Access. The Gold Standard Mahurkar * Acute Care Catheter Family Ease of insertion. Optimal flow rates. Patient comfort. A variety
More informationBalloon in Balloon (BIB )
in (BIB ) Dilatation Catheter INSTRUCTIONS FOR USE CAUTION: FEDERAL (USA) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN. Read all instructions prior to use. Distributed by: B. Braun
More informationThe evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System
The evolution of AORFIX AORFIX AAA Stent Graft now with the new AORFLEX Delivery System The confident choice for the right angles AORFIX the only AAA stent graft approved for all angulations from 0 90,
More informationGuidewire Selection. Making the Most Out of My Guidewire: LINC 2016: Leipzig Interventional Course Leipzig, Germany January 26-29, 2016
Making the Most Out of My Guidewire: Guidewire Selection LINC 2016: Leipzig Interventional Course Leipzig, Germany January 26-29, 2016 Brian DeRubertis, MD, FACS Associate Professor of Surgery Division
More informationThere are multiple endovascular options for treatment
Peripheral Rotablator Atherectomy: The Below-the-Knee Approach to Address Calcium Head On Peripheral Rotablator s front-cutting, diamond-tipped burr provides stable rotation in calcified lesions. BY SONYA
More informationABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM
ABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM Pure performance and quality: Stent graft systems by JOTEC JOTEC is an innovation-oriented company with consistent focus on its core competencies: the development
More informationI SEE THE BROADEST RANGE OF PRODUCTS THRU my smallest possible incision.*
I SEE THE BROADEST RANGE OF PRODUCTS THRU my smallest possible incision.* Edwards ThruPort Systems The complete system for minimal incision valve surgery (MIVS) Prep Guide MIVS Redefined > THRUPORT SYSTEMS
More informationChallenges. 1. Sizing. 2. Proximal landing zone 3. Distal landing zone 4. Access vessels 5. Spinal cord ischemia 6. Endoleak
Disclosure I have the following potential conflicts of interest to report: Consulting: Medtronic, Gore Employment in industry Stockholder of a healthcare company Owner of a healthcare company Other(s)
More informationTHE ENVOY FAMILY OF GUIDING CATHETERS. Supporting your neurointerventional access needs
THE ENVOY FAMILY OF GUIDING CATHETERS Supporting your neurointerventional access needs VERSATILITY & CHOICE ENVOY FAMILY OF GUIDING CATHETERS Innovating in guiding catheter technology and building on the
More informationChronic Total Occlusion (CTO) Technologies
to receive our latest news and key activities. Chronic Total Occlusion (CTO) Technologies Re-open vital channels LinkedIn page Follow us on CORDIS EMEA OUTBACK LTD Re-Entry Catheter True Lumen Re-Entry
More informationNAVIGATE DISTAL AND TORTUOUS ANATOMY
PROGREAT ALPHA PUSHINGBOUNDARIES Terumo Interventional Systems is committed to your success with innovative procedural solutions and ongoing support for your most challenging cases. We are relentlessly
More informationTalent Abdominal Stent Graft
Talent Abdominal with THE Xcelerant Hydro Delivery System Expanding the Indications for EVAR Treat More Patients Short Necks The Talent Abdominal is the only FDA-approved device for proximal aortic neck
More informationHOSPITAL CARE MEDICAL DEVICES Surgical Disposables
HOSPITAL CARE MEDICAL DEVICES Surgical Disposables AEROMED STAPLER SKIN GRAFT KNIFE BLADE 3 WAY STOPCOCK EXTENSION TUBING WITH 3-WAY STOPCOCK ENDOTRACHEAL TUBE SAFE-CATH ALL SILICON FOLLEY CATHETER AERO
More informationThe High-Flow Port Designed & Indicated for Apheresis
The High-Flow Port Designed & Indicated for Apheresis Advancing Lives and the Delivery of Health Care Bard is proud to introduce the first and only high-flow, power-injectable port designed and indicated
More informationPRODUCTS FOR THE DIFFICULT AIRWAY. Courtesy of Cook Critical Care
PRODUCTS FOR THE DIFFICULT AIRWAY Courtesy of Cook Critical Care EMERGENCY CRICOTHYROTOMY Thyroid Cartilage Access Site Cricoid Cartilage Identify the cricothyroid membrane between the cricoid and thyroid
More informationSepetka et al. (45) Date of Patent: May 3, ) VARIABLE STIFFNESS CATHETER 4,739,768 4/1988 Engelson.
United States Patent (19) 11 USOO5308342A Patent Number: Sepetka et al. (45) Date of Patent: May 3, 1994 54) VARIABLE STIFFNESS CATHETER 4,739,768 4/1988 Engelson. o 4,775,371 10/1988 Mueller, Jr.... 604/280
More informationPruitt-Inahara Carotid Shunt
Pruitt-Inahara Carotid Shunt Instructions for Use - English Pruitt-Inahara Carotid Shunt Pruitt-Inahara Carotid Shunt (Outlying) (Model # 2000-19, 2000-49, 2000-48, e2000-19, e2000-49, e2000-48) Inahara-Pruitt
More informationEffectiveness of IVUS in Complex Cases
Effectiveness of IVUS in Complex Cases Satoru Sumituji,M.D. Rinku General Medical Center IVUS is can provide images of the vessel wall and the tissue around the vessel which cannot be viewed by angiography.
More informationCardioplegia Circuit Products { ANTEGRADE}
Cardioplegia Circuit Products { ANTEGRADE} Antegrade cannulae are designed to deliver cardioplegia solution to the heart via the coronary ostia in the normal direction of blood flow (antegrade perfusion).
More informationCardioplegia Circuit Products { CARDIOPLEGIA ADAPTERS}
Cardioplegia Circuit Products { CARDIOPLEGIA ADAPTERS} Cardioplegia adapters are designed to permit customization of the cardioplegia circuit. Medtronic adapters can be used to connect multiple cardioplegia
More informationCLARIVEIN INFUSION CATHETER
CLARIVEIN INFUSION CATHETER General Product Description Overview The ClariVein Infusion Catheter (ClariVein -IC) is an infusion catheter system designed to introduce physician-specified medicaments into
More informationHemodynamic Monitoring and Circulatory Assist Devices
Hemodynamic Monitoring and Circulatory Assist Devices Speaker: Jana Ogden Learning Unit 2: Hemodynamic Monitoring and Circulatory Assist Devices Hemodynamic monitoring refers to the measurement of pressure,
More informationRhinology Products. Rhinology Products. Superior solutions for superior patient care.
Rhinology Products Superior solutions for superior patient care. The Doyle Open-Lumen Splint addresses the problem of potential closure of the airway lumen by a hypertrophied turbinate. We also offer the
More informationPruitt Irrigation Occlusion Catheter. English Instructions for Use. Pruitt Irrigation Occlusion Catheter
English Instructions for Use Pruitt Irrigation Occlusion Catheter (Model Numbers 2102-09, e2102-09) Instructions for Use - English Concept Balloon tipped catheters have been used to occlude vessels for
More informationZenith Alpha T HORACIC ENDOVASCULAR GRAFT
Device description Zenith Alpha T HORACIC ENDOVASCULAR GRAFT www.cookmedical.com AI-D21181-EN-F Modular design The two-piece modular system allows the physician to customize a graft system to fit each
More informationProtecting Patients. Preserving Access.
MAHURKAR * Family of Acute Care Catheters Protecting Patients. Preserving Access. A full spectrum of acute care catheters for use in hemodialysis, apheresis, infusion and renal replacement therapy The
More informationFIND YOUR IDEAL CANNULAE CATALOG. Designed for your smallest patients
FIND YOUR IDEAL PEDIATRIC CANNULAE CATALOG Designed for your smallest patients CONTENTS Extracorporeal Circuit Arterial Cannulae... 4 Femoral Cannulae... 6 Venous Cannulae... 9 Cardioplegia Circuit Antegrade
More informationRuby Coil. Large Volume Detachable Coils
Ruby Coil Ruby Case Examples 38 mm Hepatic Artery Aneurysm Pulmonary AVM 2 Coils Dr. James Benenati Miami Cardiac and Vascular Institute, FL Y90 Embolization Type 2 Endoleak Dr. J Moskovitz Florida Hospital,
More informationOptimizing Accuracy of Aortic Stent Grafts in Short Necks
Optimizing Accuracy of Aortic Stent Grafts in Short Necks Venkatesh Ramaiah, MD, FACS Medical Director Arizona Heart Hospital Director Peripheral Vascular and Endovascular Research Arizona Heart Institute
More informationPetite Wound Drainage System. 13mm CWV Drainage System. CWSump. CWV with Trocar
CWVDrain Designed to assure optimum cosmetic results Tapered, hubless design provides atraumatic insertion and removal Internal ribs prevent collapsing or kinking Large 150cc capacity reservoir decreases
More informationExtracorporeal Circuit Cannulae { VENOUS}
Extracorporeal Circuit Cannulae { VENOUS} Medtronic are designed to provide optimal venous drainage while providing flexibility and ease of use. We offer a variety of single stage venous cannulae with
More informationDocument No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017
Central Venous Catheter Device Description Multi-lumen catheters incorporate separate, non-communicating vascular access lumens within a single catheter body. Minipunctur Access Sets And Trays: Used for
More informationTranscatheter Aortic Valve Implantation Management of risks and complications
Transcatheter Aortic Valve Implantation Management of risks and complications TAVI Summit, Seoul, Korea, Spetember 3rd, 2011 Alain Cribier University of Rouen, France Complications of TAVI Depending on
More informationDISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management
DISCOVER NEW HORIZONS IN FLUID DRAINAGE Bringing Safety and Convenience to Fluid Drainage Management DRAIN ASEPT Pleural and Peritoneal Drainage Catheter System 600mL or 1,000mL Evacuated Drainage Bottle
More informationGuide Wires design and selection Abbott Vascular. All rights reserved.
Guide Wires design and selection the cardiac catheter was...the key in the lock Cournand AF, Nobel lecture December 11, 1956; nowadays, the coronary guidewire is the master key to all locks Colombo et
More informationNC EMERGE TM PTCA Dilatation Catheter
LEARN MORE Indications, contraindications, warnings and instructions for use can be found in the product labeling supplied with each device. Information for use only in countries with applicable health
More informationMARKING RING VEIN GRAFT VALVE INSTRUMENTS. Hook, Valve. TFX SURGICAL SPECIALTIES Phone Toll Free: Fax:
355838 351785 351749 355175 MARKING RING VEIN GRAFT MARKING RING-VEIN GRAFT The aorta to coronary saphenous vein graft is widely used for the treatment of coronary atherosclerosis. Assessment of the post-operative
More informationFinally, the Control You Need to Deliver Accurate Treatment
Finally, the Control You Need to Deliver Accurate Treatment LIFESTREAM Covered Stent. has joined BD When you reach for a balloon expandable stent, you require accuracy. The LIFESTREAM Balloon Expandable
More informationNavigate Complex Interventions at Every Turn
Navigate Complex Interventions at Every Turn Keep Driving Forward The portfolio of Catheters places the power in your hands. Navigate tortuous anatomy with agility and precision. No matter the challenge,
More information1 Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis. N Engl J Med 352;13, March 31, 2005
The risk of ischemic stroke in patients with Intracranial Atherosclerotic Disease (ICAD) ranges from 7 to 24%. 1,2 Developed specifically for the treatment of ICAD, the Wingspan Stent System and Gateway
More informationYour heart is a muscular pump about the size of your fist, located
How Your Heart Works Your heart is a muscular pump about the size of your fist, located slightly to the left and behind your breastbone. Its function is to pump blood throughout your body. As your heart
More informationTechnique. Technique. Technique. Monitoring 1. Local anesthetic? Aseptic technique Hyper-extend (if radial)
Critical Care Monitoring Hemodynamic Monitoring Arterial Blood Pressure Cannulate artery Uses 2 Technique Sites Locate artery, prep 3 1 Technique Local anesthetic? Aseptic technique Hyper-extend (if radial)
More informationTHE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT
THE THE MORE MORE NATURAL APPROACH Natural Approach TO Optimal Fit TO OPTIMAL FIT Conformability without Compromise THE STANDARD IN Conformability AND Designed for flexibility and conformability in tortuous
More informationAdult Cannulae. product catalog
Adult Cannulae product catalog cardiac cardiac surgery solutions Table of Contents Arterial Cannulae 4 Curved Tip Aortic Arch Cannulae 4 Straight Tip Aortic Arch Cannulae 11 Flexible Aortic Arch Cannulae
More informationIndications. The AngioVac cannula is intended for use as a venous drainage cannula and for the removal of fresh, soft thrombi or emboli
Indications Straight Cannula or Cannula with 20 O Angle 17F Working Channel The AngioVac cannula is intended for use as a venous drainage cannula and for the removal of fresh, soft thrombi or emboli Radiopaque
More informationMICS & FEMORAL CANNULAE
MICS & FEMORAL CANNULAE Cannulae that can High performance cannulae for direct and femoral cannulation, either in conventional or minimally invasive cardiac surgery 1. Pfeiffer et al. Interactive Cardiovascular
More informationinterventional cardiology
interventional cardiology interventional cardiology prepare access navigate diagnose intervene close integrate Merit Medical offers an integrated suite of products designed to support interventional cardiology
More informationThruPort systems ProPlege peripheral retrograde cardioplegia device
ThruPort systems ProPlege peripheral retrograde cardioplegia device Training Module Lessons Lesson 1: ProPlege device Lesson 2: Preparing for the case Lesson 3: Utilizing the device Lesson 4: Troubleshooting
More informationCombine the best of both worlds
S c i e n c e B a s e d E v o l u t i o n s l e a d t o R e v o l u t i o n a r y S o l u t i o n s PIONEER CoCr STENT ON DEB Combine the best of both worlds A next step in cardiovascular treatment should
More informationAnatomy and Classification of Aortic Dissection
Aortic dissection is the most common disorder of the aorta that brings a patient to the emergency room. If left untreated, 75 percent of sufferers die in the first two weeks and 90 percent die in the first
More information5F Devices with 0.035
Ambulatory mamagement for PAD endovascular treatment 5F Devices with 0.035 Flavio Airoldi, MD Multmedica IRCCS Milan - ITALY flavio.airoldi@multimedica.it Is there a need for low profile delivery systems?
More informationTips and Tricks to Deliver a Stengraft to the Ascending Aorta
Tips and Tricks to Deliver a Stengraft to the Ascending Aorta Tilo Kölbel, MD, PhD University Heart Center University Hospital Eppendorf Hamburg, Germany Disclosures Research-grants, travelling, proctoring
More informationInstructions for Use. IJ Catheter Ultrasound Model Version 2400 Series
Instructions for Use IJ Catheter Ultrasound Model Version 2400 Series 3601 Sagamore Parkway North, Suite B Lafayette, IN 47904 Phone 765.742.4813 www.hemocleanse.com Instructions Revision 3.0 2014 Table
More informationPhoenix Atherectomy System Product Overview /LB
Phoenix Atherectomy System Product Overview Phoenix Atherectomy System- The next generation of atherectomy The first hybrid atherectomy system available Combines the benefits of existing atherectomy systems
More informationANGIOFLOW DIAGNOSTIC CATHETERS
ANGIOFLOW DIAGNOSTIC CATHETERS + Our difference is your speciality COMMITMENT AWARD WINNING CUSTOMER SERVICE The customer is our number one priority and we are committed to consistently delivering high
More informationThe Role of Mechanical Circulatory Support in Cardiogenic Shock: When to Utilize
The Role of Mechanical Circulatory Support in Cardiogenic Shock: Presented by Nancy Scroggins ACNP, CNS-CC CV Surgery ACNP Bayshore Medical Center The Role of Mechanical Circulatory Support in Cardiogenic
More information