Lux. Five Distinct Polysaccharide Phases to Resolve 92 % of Your Enantiomers* Lux Cellulose-1. Lux Cellulose-3. Lux Cellulose-2.

Size: px
Start display at page:

Download "Lux. Five Distinct Polysaccharide Phases to Resolve 92 % of Your Enantiomers* Lux Cellulose-1. Lux Cellulose-3. Lux Cellulose-2."

Transcription

1 Five Distinct Polysaccharide Phases to Resolve 9 % of Your Enantiomers* If Lux analytical columns ( 4.6 mm ID) do not provide at least an equivalent or better separation as compared to a competing column of the same particle size, similar phase and dimensions, send in your comparative data within 45 days and keep the Lux column for FREE. Lux columns offer a wide and complementary range of enantioselectivity for even the most difficult chiral separation projects. igh efficiency and loading capacity Stable in ormal Phase, Polar rganic, SF, and Reversed Phase onditions 3 µm and 5 µm packed columns and µm bulk media for scale up Technical Specifications Particle Size 3, 5, * µm p Stability -9 Maximum Pressure 3 bar Temperature Range -5 Shipping Solvent n-exane/-propanol (9:, v/v) SF Please inquire for availability ellulose-- Lux chiral columns are made with high quality silica, and undergo a specialized coating and packing process that ensures high efficiencies while maintaining essential enantiorecognition abilities. l l Lux ellulose- ellulose tris(3,5-dimethylphenylcarbamate) chiral lc LuX l ellulose-- ellulose- Lux ellulose- ellulose tris(3-chloro-4-methylphenylcarbamate) Lux ellulose-3 ellulose tris(4-methylbenzoate) l l ellulose-- Amylose-- Lux ellulose-4 ellulose tris(4-chloro-3-methylphenylcarbamate) Lux Amylose- Amylose tris(5-chloro--methylphenylcarbamate) * Based on 33 compounds screened on all five Lux phases Phenomenex 85

2 Achieve ptimal Resolution by Screening all Five omplementary Lux hiral olumns Utilizing differences in selectivity can help develop methods more efficiently by offering broad and contrasting chiral recognition abilities. Lux chiral selectors provide a variety of selectivities that give you the opportunity to screen for the ideal chiral separation. Etozolin SF LUX chiral lc Lux ellulose- a =.6 Lux ellulose-4 a =.35 Lux Amylose- a =.45 Lux ellulose- a =.48 App ID 948 App ID 946 App ID 95 App ID 947 onditions for all columns: Dimensions: 5 x 4.6 mm Mobile Phase: Acetonitrile /. % Diethylamine in mm 4 3 (6:4) Flow Rate: ml/min Detection: nm S ptimal Resolution Lux ellulose-3 a =.7 App ID 95 Based on a five phase screen under reversed phase conditions, the optimal chiral stationary phase for resolving Etozolin is Lux ellulose-3. omparative separations may not be representative of all applications. 86 Phenomenex

3 Lux hiral Stationary Phases The Lux line of cellulose and amylose-based chiral stationary phases includes five complementary selectivities. Lux Amylose-: hlorinated Amylose hiral Selector This first-to-market chlorinated amylose phenylcarbamate derivative offers complex chiral recognition components that greatly increase the chances of achieving chiral resolution. l Amylose-- Amylose tris(5-chloro--methylphenylcarbamate) -Phenylcyclohexanone Lux 5 µm Amylose- a =.4 App ID 898 a =.4 *IRALPAK 5 µm AD - App ID 897 onditions for both columns: Dimensions: 5 x 4.6 mm Mobile Phase:. % Diethylamine in exane /. % Diethylamine in Isopropanol (9:) Flow Rate: ml/min Detection: nm min min SF Lux ellulose-: Dimethyl ellulose hiral Selector This universally trusted cellulose phenylcarbamate derivative is absolutely essential to any chiral screen. Metoprolol a =.38 Lux 5µm ellulose- App ID 74 a =.6 *IRALEL 5µm D- App ID 743 ellulose-- ellulose tris(3,5-dimethylphenylcarbamate) onditions for both columns: Dimensions: 5 x 4.6 mm Mobile Phase:. % Diethylamine in Acetonitrile /. % Diethylamine in Isopropanol (95:5) Flow Rate: ml/min Detection: nm chiral lc LuX min omparative separations may not be representative of all applications. Phenomenex 87

4 Lux ellulose-: hlorinated ellulose arbamate Phase This first-to-market halogenated cellulose phenylcarbamate derivative offers unique chiral recognition abilities that complement the rest of the Lux family of columns. l ellulose-- Tolperisone a =.69 Lux 5 µm ellulose- App ID a =.7 *IRALEL 5 µm D- App ID 73 ellulose tris(3-chloro-4-methylphenylcarbamate) onditions for both columns: Dimensions: 5 x 4.6 mm Mobile Phase:. % Diethylamine in exane /. % Diethylamine in Isopropanol (9:) Flow Rate: ml/min Detection: nm 4 6 min 4 6 min 3 3 SF LUX chiral lc Lux ellulose-3: ellulose Ester Phase This cellulose methylbenzoate derivative offers distinct and complementary chiral recognition abilities. ellulose- Disopyramide a =.8 R s =.3 Lux 5 µm ellulose-3 App ID min a =.7 R s =.3 *IRALEL 5 µm J- App ID min ellulose tris(4-methylbenzoate) onditions for both columns: Dimensions: 5 x 4.6 mm Mobile Phase:. % Diethylamine in exane /. % Diethylamine in Ethanol (9:) Flow Rate: ml/min Detection: nm omparative separations may not be representative of all applications. 88 Phenomenex

5 Lux ellulose-4: hlorinated ellulose arbamate Phase This chlorinated cellulose phenylcarbamate derivative offers unique chiral recognition abilities. l ellulose-- ellulose tris(4-chloro-3-methylphenylcarbamate) Tolperisone a =.7 Lux 5 µm ellulose-4 App ID 953 *IRALPAK 5 µm AD - a =. App ID 955 onditions for all columns: Dimensions: 5 x 4.6 mm Mobile Phase:. % Diethylamine in exane /. % Diethylamine in Isopropanol (9:) Flow Rate: ml/min Detection: nm 4 6 min 4 6 min 3 3 omparative separations may not be representative of all applications. SF hiral Screening and Separation Services PL SF Preparative Training For more information on our services or to begin a project, please contact your local Phenomenex chiral expert or us at: phenologix@phenomenex.com You can also visit us on the web at: chiral lc LuX Phenomenex 89

6 If Lux analytical columns ( 4.6 mm ID) do not provide at least an equivalent or better separation as compared to a competing column of the same particle size, similar phase and dimensions, send in your comparative data within 45 days and keep the Lux column for FREE. rdering Information 3 µm Analytical olumns (mm) SecurityGuard artridges (mm) Phases 5 x. 5 x. 5 x 4.6 x x x x.* 4 x 3.* /pk /pk ellulose- B-4458-B F-4458-B B-4458-E D-4458-E F-4458-E G-4458-E AJ-84 AJ-843 ellulose- B-4456-B F-4456-B B-4456-E D-4456-E F-4456-E G-4456-E AJ-8398 AJ-8366 ellulose-3 B-449-B F-449-B B-449-E D-449-E F-449-E G-449-E AJ-86 AJ-86 ellulose-4 B-449-B F-449-B B-449-E D-449-E F-449-E G-449-E AJ-866 AJ-867 Amylose- B-447-B F-447-B B-447-E D-447-E F-447-E G-447-E AJ-847 AJ-847 for ID:. 3. mm mm SF 5 µm Analytical olumns (mm) SecurityGuard artridges (mm) Phases 5 x. 5 x 4.6 x x x x.* 4 x 3.* /pk /pk ellulose- B-4459-B B-4459-E D-4459-E F-4459-E G-4459-E AJ-84 AJ-843 ellulose- B-4457-B B-4457-E D-4457-E F-4457-E G-4457-E AJ-8398 AJ-8366 ellulose-3 B-4493-B B-4493-E D-4493-E F-4493-E G-4493-E AJ-86 AJ-86 ellulose-4 B-449-B B-449-E D-449-E F-449-E G-449-E AJ-866 AJ-867 Amylose- B-447-B B-447-E D-447-E F-447-E G-447-E AJ-847 AJ-847 for ID:. 3. mm mm LUX chiral lc 5 µm Semi-Prep olumns (mm) SecurityGuard artridges (mm) Phases 5 x. 5 x. x. /3pk ellulose- F G AJ-844 ellulose- F G AJ-8399 ellulose-3 F G AJ-863 ellulose-4 F-449- G-449- AJ-868 Amylose- F-447- G-447- AJ-847 for ID: 9 6 mm µm Bulk Media Phases g kg ellulose- 4G K-4473 ellulose- 4G K-4464 Please inquire for µm Lux Amylose-, ellulose-3 or ellulose-4 media. 5 µm Axia Packed Preparative olumns (mm) SecurityGuard artridges (mm) Phases 5 x. 5 x. 5 x 3 5 x 5 5 x.** 5 x 3. + /ea /ea ellulose- F-4459-P-AX G-4459-P-AX G-4459-U-AX G-4459-V-AX AJ-845 AJ-846 ellulose- F-4457-P-AX G-4457-P-AX G-4457-U-AX G-4457-V-AX AJ-84 AJ-84 ellulose-3 F-4493-P-AX G-4493-P-AX G-4493-U-AX G-4493-V-AX AJ-864 AJ-865 ellulose-4 F-449-P-AX G-449-P-AX G-449-U-AX G-449-V-AX AJ-869 AJ-863 Amylose- F-447-P-AX G-447-P-AX G-447-U-AX G-447-V-AX AJ-8473 AJ-8474 for ID: 8 9 mm 3 49 mm *SecurityGuard Analytical artridges require holder, Part o. : KJ-48 SemiPrep SecurityGuard artridges require holder, Part o.: AJ-7 **PREP SecurityGuard artridges require holder, Part o. : AJ-83 PREP SecurityGuard artridges require holder, Part o. : AJ µm Method Screening Kits (save % when purchased as a kit) 5 x 4.6 mm 5 x 4.6 mm Screening Kit K-8483 K-848 Kit contains one column of each phase. olumn Performance heck Standard Part o. Description Unit Price AL-84 hiral Test Mix o. 5 (Lux) ea *IRALPAK, IRALEL, AD, D-, and J- are registered trademarks of DAIEL hemical Industries, Ltd. olumns used for comparison were manufactured by DAIEL hemical Industries, Ltd. 9 Phenomenex

SIMPLIFIED CHIRAL SEPARATIONS. FIVE Complementary Chiral Phases. for Greater Selectivity. Resolve 92 %

SIMPLIFIED CHIRAL SEPARATIONS. FIVE Complementary Chiral Phases. for Greater Selectivity. Resolve 92 % SIMPLIFIED IRAL SEPARATIS FIVE omplementary hiral Phases for Greater Selectivity Resolve 9 % of all your Enantiomers using Screening Kits * FREE hiral Screening and Separation Services. *Based on screening

More information

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced SIMPLIFIED IRAL SEPARATIS Lux ellulose- Guaranteed Alternative to IRALEL D- Exceptional Quality Sensibly Priced Lux ellulose- ellulose tris(3,5-dimethylphenylcarbamate) This dimethyl cellulose selector

More information

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases T-1164 APPLICATIS Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases Marc Jacob, Liming Peng, Michael Klein, Tom eveland,

More information

COSMOSIL CHiRAL Series

COSMOSIL CHiRAL Series Immobilized Polysaccharide Derivative-Based Chiral Columns CSMSIL CiRAL Series Immobilized chiral selectors can withstand many different solvents Sharpen peaks with 3 μm particles Preparative separations

More information

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB: Exceed your Purification Goals Guaranteed The Axia Prep Column Advantage Extended column lifetime Reproducibility: column-to-column and batch-to-batch igher efficiency Improved peak shape Increased loadability

More information

Prep Columns. and Bulk Media. and Bulk Media

Prep Columns. and Bulk Media. and Bulk Media Prep Columns and Bulk Media Axia Columns...346-355 Process Chromatography...356-36 Bulk Media...356-36 Columns, Scout and Preparative...359-36 Sepra Bulk Sorbents... 36 Prep Columns and Bulk Media 345-36

More information

Immobilized Chiral Stationary Phases

Immobilized Chiral Stationary Phases Immobilized Chiral Stationary Phases Immobilization Silica Polymer Proprietary Immobilization Techniques CSP CIRALPAK CIRALPAK CIRALPAK CIRALPAK CIRALPAK CIRALPAK Immobilized Chiral Stationary Phases I-CSP

More information

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1 APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there

More information

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit Kinetex 5 µm Core-Shell Columns Deliver Significant Improvements in Chromatographic Efficiency and Resolution versus Traditional Fully Porous 5 µm Columns Philip J. Koerner and Jeff Layne Phenomenex, Inc.,

More information

Ultimate Core Performance to Maximize Your Investment

Ultimate Core Performance to Maximize Your Investment Thermo Scientific Accucore HPL olumns Phase Overview Ultimate ore Performance to Maximize Your Investment Phase Overview Founded on state-of-the-art ore Enhanced Technology and utilizing vast experience

More information

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance

More information

Preparative Chromatography Meets UHPLC

Preparative Chromatography Meets UHPLC Preparative Chromatography Meets UHPLC The Power of Kinetex Core-Shell Technology with the Performance of Piston Packed Prep Columns Ultra-High Efficiencies Ultra-Long Lifetimes NO Added Pressure Two Award

More information

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology. Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology Jeff Layne, Phenomenex, Inc. Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 951 USA With virtually

More information

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market Better UHPLC Performance Starts NW.7 µm Core-Shell * Columns The IRST and NLY sub- µm core-shell columns on the market Phenomenex India Laxmi Cyber City, Ground loor, B Block, Survey no: Kondapur, Hyderabad

More information

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed! U.S. Patent No. 6, 162, 362 Column Protection for UHPLC, HPLC to PREP Protect HPLC columns and extend lifetime Virtually no change in chromatography Available in analytical, semi-prep, and preparative

More information

YMC Chiral columns. Polysaccharides NEA(R)(S) CD BR

YMC Chiral columns. Polysaccharides NEA(R)(S) CD BR YMC Chiral columns Polysaccharides NEA(R)(S) CD BR HPLC Columns for Optical Isomer Separation Chirality has become vitally important in the production of pharmaceuticals, agrochemicals, food and related

More information

Core-Shell Technology for Proteins and Peptides

Core-Shell Technology for Proteins and Peptides Core-Shell Technology for Proteins and Peptides Better BioSeparations on HPLC and UHPLC Systems www.phenomenex.com/aeris Aeris Core-Shell Technology Core-Shell Particles Precision Engineered for Protein

More information

Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids

Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids David S. Bell, Carmen T. Santasania, Jennifer Claus, Wayne K. Way, and Craig R. Aurand Supelco, Div. of

More information

YMC CHIRAL columns. Polysaccharides NEA(R)(S) CD BR

YMC CHIRAL columns. Polysaccharides NEA(R)(S) CD BR YMC CHIRAL columns Polysaccharides NEA(R)(S) CD BR HPLC Columns for Optical Isomer Separation Chirality has become vitally important in the production of pharmaceuticals, agrochemicals, food and related

More information

Ultra Columns. also available. ordering note

Ultra Columns. also available. ordering note : 3μm or 5μm particles; 100Å pore size Our broadest selection of stationary phases, including unique phases. High density bondings, for maximum retention. High-purity, Type B silica gives excellent peak

More information

C30 ISOMERS HAVE MET THEIR MATCH

C30 ISOMERS HAVE MET THEIR MATCH C30 ISOMERS HAVE MET THEIR MATCH INTRODUCING THE NEW! Built on proven Fused-Core particle technology, the is designed to deliver fast separations ideal for lipids and isomers compared to your C18. FEATURES

More information

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput ULTIMATE HPLC/UHPLC CMB Kinetex Luna mega Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput NEW MEGA Core-Shell Technology Luna mega Luna mega PS Kinetex. Kinetex Luna mega Cutting

More information

Sepax Technologies, Inc.

Sepax Technologies, Inc. Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid

More information

METHAMPHETAMINE & AMPHETAMINE

METHAMPHETAMINE & AMPHETAMINE METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine Rapid and Accurate Chiral Separation Polysaccharide Chiral Chiral LC LC Columns and SFC PHEN-RUO-49 Revision: Lux 3 µm AMP Column High Efficiency LC/MS/MS

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Poor retention

More information

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Yes You Can! New! Amazing EVO C18. Core-Shell Technology Core-Shell Technology Yes You Can! New! Amazing EVO C8 Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity THE PAST Fully Porous You used

More information

[ APPLICATION NOTE ] The Separation of 8 -THC, 9 -THC, and Their Enantiomers by UPC 2 Using Trefoil Chiral Columns INTRODUCTION APPLICATION BENEFITS

[ APPLICATION NOTE ] The Separation of 8 -THC, 9 -THC, and Their Enantiomers by UPC 2 Using Trefoil Chiral Columns INTRODUCTION APPLICATION BENEFITS The Separation of 8 -THC, 9 -THC, and Their Enantiomers by UPC 2 Using Trefoil Chiral Columns Jacquelyn Runco, Andrew Aubin, and Catharine Layton Waters Corporation, Milford, MA, USA APPLICATION BENEFITS

More information

Choosing Preparative Columns

Choosing Preparative Columns Choosing Preparative Relationship between Column I.D., Sample Loading Volume and Flow Rate In preparative operations, column internal diameter sizes from 6.0 to 100 mm are widely used. When the analytical

More information

Ultra Columns HPLC COLUMNS

Ultra Columns HPLC COLUMNS Acetaminophen, Narcotic Analgesics.............519 Aldehydes, Ketones...........................500 Beclomethasone.............................523 Corticosteroids..............................529 Explosives..................................501

More information

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable,

More information

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 1 PFP Application Note Clinical Research Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd Abstract

More information

TSKgel Size Exclusion Chromatography Columns

TSKgel Size Exclusion Chromatography Columns TSKgel Size Exclusion Chromatography Columns Silica-based for protein analysis: TSKgel SW mab TSKgel SW TSKgel SWXL TSKgel SuperSW Polymer-based for desalting: TSKgel BioAssist DS Columns Polymethacrylate-based

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Poor

More information

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns. For Far Greater UHPLC Column Performance... You Must Have Kinetex Core-Shell UHPLC Columns www.phenomenex.com/kinetex The UHPLC Core-Shell Advantage Kinetex Core-Shell Technology produces increased efficiencies

More information

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm

More information

Agilent Technologies Prep LC Columns

Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies has always taken seriously its responsibility to ensure your success. That s why all our instruments and supplies

More information

176 YMC Chiral Columns

176 YMC Chiral Columns 176 YMC Chiral Columns YMC Chiral Columns 177 Chiral Columns Content YMC Chiral NEA(R)(S)... 178-181 YMC Chiral CD BR... 182-185 Ordering Information... 186 HPLC Columns for Optical Isomer Separation Introduction

More information

Roc On with These Dependable LC Columns

Roc On with These Dependable LC Columns Roc LC s Conventional column built to be the cornerstone for your lab; pressure rated for any 400 bar system. Solid and reliable delivers the peak shape, reproducibility, ruggedness, and performance you

More information

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) Michael Rummel, Matthew Trass, Michael Campognone, and Sky Countryman Phenomenex, Inc., 411 Madrid Avenue, Torrance,

More information

250 YMC Chiral Columns

250 YMC Chiral Columns 250 YMC Chiral Columns YMC Chiral Columns 251 Chiral Columns Contents Verified stability with TFA CHIRAL ART Coated Polysaccharide Derivatives Series... 252-263 Only REAL alternative on the market! CHIRAL

More information

HPLC. Varian Dynamax Preparative HPLC Columns

HPLC. Varian Dynamax Preparative HPLC Columns HPLC Varian Dynamax Preparative HPLC Columns Preparative HPLC Simple, successful and economical Linear scale-up move from analytical separation to preparative purification quickly and simply. Dynamic Axial

More information

A Validated Chiral Liquid Chromatographic Method for The Enantiomeric Separation of Dapoxetine Hydrochloride

A Validated Chiral Liquid Chromatographic Method for The Enantiomeric Separation of Dapoxetine Hydrochloride Received on 15/05/2012; Revised on 22/05/2012; Accepted on 09/06/2012 A Validated Chiral Liquid Chromatographic thod for The Enantiomeric Separation of Dapoxetine Hydrochloride T.Rohith 1 and S. Ananda

More information

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky

More information

Figure 1. Core-Shell Particle Technology

Figure 1. Core-Shell Particle Technology Purification of Chlorogenic cid from Green Coffee using Kinetex Core-Shell Technology in xia Preparative Formats Zeshan qeel Technical Magician Zeeshan loves to collect watches and the ack to the Future

More information

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column Diamond Analytics Technical Note: T131-1 Separation of Vitamin D and Vitamin D Metabolites on FLARE C1 MM (Mixed Mode) HPLC Column Introduction In this technical note, the versatility of the diamond-based

More information

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and

More information

Natural Product Preparative HPLC Purification from Complex Crude Extraction Mixtures by Granular Bonded and Unbonded Silica Gel

Natural Product Preparative HPLC Purification from Complex Crude Extraction Mixtures by Granular Bonded and Unbonded Silica Gel Natural Product Preparative PLC Purification from Complex Crude Extraction Mixtures by Granular Bonded and Unbonded Silica Gel Lori Sandford Paul Garms Theresa Riley Jochen Saar Grace Davison Discovery

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns Core-Shell Technology 11 HPLC Myths Uncovered & Why You Must Have Kinetex Core-Shell HPLC Columns 2.6 www.phenomenex.com/kinetex HPLC myths have been around since the early 19 s! From the one about the

More information

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants Selectivity Comparison of Agilent Poroshell 1 Phases in the Separation of Butter Antioxidants Application Note Food Testing & Agriculture Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd. Abstract

More information

Comparison of a UPLC Method across Multiple UHPLC Systems

Comparison of a UPLC Method across Multiple UHPLC Systems Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid

More information

ACE C18-AR Use the Power!

ACE C18-AR Use the Power! combines the retention and separation characteristics of a C18 phase with the extra selectivity of an integral phenyl functional group. The combination provides extra resolving power for a wide variety

More information

Analytical and Preparative SFC Columns

Analytical and Preparative SFC Columns Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...

More information

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Application Note Pharmaceutical QA/QC Author Siji Joseph Agilent Technologies, Inc. Bangalore,

More information

Separation and identification of cis and trans isomers of 2-butene-1,4-diol and lafutidine by HPLC and LC-MS *

Separation and identification of cis and trans isomers of 2-butene-1,4-diol and lafutidine by HPLC and LC-MS * 74 Journal of Zhejiang University SIEE ISS 19-395 http://www.zju.edu.cn/jzus E-mail: jzus@zju.edu.cn Separation and identification of cis and trans isomers of 2-butene-1,4-diol and lafutidine by PL and

More information

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns Separation of Macrocyclic Lactones (Avermectins) on FLARE C8 MM & FLARE C8+ Columns Introduction Diamond Analytics Technical Note: T05- Avermectins are a series of 6-membered macrocyclic lactone derivatives

More information

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability YMC-Actus Columns for Semi-preparative HPLC Selectivity Durability Loadability Fast semi-preparative chromatography Semi-preparative chromatography is the link between analytical HPLC and preparative LC.

More information

InertSustainBio C18. Rapid Separations of Proteins and Peptides

InertSustainBio C18. Rapid Separations of Proteins and Peptides InertSustainBio C18 Rapid Separations of Proteins and Peptides High Recoveries of Proteins and Peptides The 200A pore size silica creates the opportunity to separate compounds having a molecular weight

More information

Kromasil The way to peak performance in liquid chromatography

Kromasil The way to peak performance in liquid chromatography Kromasil The way to peak performance in liquid chromatography Kromasil product catalogue Kromasil is offered in a wide assortment of columns and in bulk amounts from parts of kilograms to metric tons.

More information

HICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies NEW PRODUCTS Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email: sales@hichrom.co.uk

More information

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. Fast High peak capacity Low back pressure PROTEIN PEPTIDE UHPLC COLUMNS Put these new, high-performance

More information

ACE Excel UHPLC Columns

ACE Excel UHPLC Columns Excel UHPLC Columns info@ace-hplc.com Advanced Chromatography Technologies Ltd www.ace-hplc.com Australia & New Zealand contact: infor@winlab.com.au or call + 0 Outline Introduction Key Product Points

More information

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology Core-Shell Technology Kinetex EVO C8 HPLC/UHPLC Core-Shell Columns Greater Polar Retention with % Aqueous Stability Robust Methods from ph - Improved Peak Shape for Bases NEW.7 µm NEW. µm µm Unconventionally

More information

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you! Core-Shell Technology NEW Kinetex enyl Biph Biphenyl TM S TM Selectivity that a C8 just can t give you! S Bip he ylhenyl Bnip Remarkable Separation Power Rugged and Reliable % Aqueous Stable Kinetex Core-Shell

More information

Catalogue. Resins and Columns For High Performance Liquid Chromatography

Catalogue. Resins and Columns For High Performance Liquid Chromatography Catalogue Resins and Columns For High Performance Liquid Chromatography Updated August 11, 2008 Contents Benson Polymeric provides premium polymeric column packing materials and prepacked columns for use

More information

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix Application Note Separation of clindamycin phosphate and process impurities Category Pharmaceutical analysis Matrix Drugs Method UHPLC Keywords Antibiotics, process impurities, quality control Analytes

More information

YMC Chiral Columns. CHIRAL ART Polysaccharides YMC CHIRAL NEA & CD BR. NP / RP / SFC Coated / Immobilised (Semi-)prep.

YMC Chiral Columns. CHIRAL ART Polysaccharides YMC CHIRAL NEA & CD BR. NP / RP / SFC Coated / Immobilised (Semi-)prep. NEW & UNIQUE CHIRAL SELECTOR! YMC Chiral Columns Polysaccharides YMC CHIRAL NEA & CD BR NP / RP / SFC Coated / Immobilised (Semi-)prep www.ymc.de 2 Chiral Columns HPLC Columns for Optical Isomer Separation

More information

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined ProteCol LC Columns - Exceed the limit A premium inert range of LC columns delivering optimal peak shape. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing

More information

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1. APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,

More information

UNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance

UNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance UNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance Revolutionary aqueous durability Aqueous to non-aqueous High speed normal phase separation 3μm particle size Superior resolution

More information

CHAPTER-2. Table of Contents. S.No. Name of the Sub-Title Page No. 2.1 Literature survey for simultaneous estimation of selected drugs by RP-HPLC

CHAPTER-2. Table of Contents. S.No. Name of the Sub-Title Page No. 2.1 Literature survey for simultaneous estimation of selected drugs by RP-HPLC 21 CHAPTER-2 Table of Contents Chapter 2. Literature Survey S.No. Name of the Sub-Title Page No. 2.1 Literature survey for simultaneous selected drugs by RP-HPLC 2.2 Literature survey for simultaneous

More information

Chromatography on Immobilized Artificial Membrane

Chromatography on Immobilized Artificial Membrane Chromatography on Immobilized Artificial Membrane Principles of measuring compounds affinity to phospholipids using immobilized artificial membrane chromatography Chromatography on Immobilized Artificial

More information

GlycanPac AXR-1 Columns

GlycanPac AXR-1 Columns CHRMATGRAPHY GlycanPac AXR- Columns For High Resolution Glycan Analysis Product Specifications The Thermo Scientific GlycanPac AXR- columns are highperformance, silica-based HPLC columns for simultaneous

More information

Optimizing Chiral Separations and Purification of Enantiomers Through Selective Sample Slicing and Column Switching

Optimizing Chiral Separations and Purification of Enantiomers Through Selective Sample Slicing and Column Switching Optimizing Chiral Separations and Purification of Enantiomers Through Selective Sample Slicing and Column Switching Application Note PHA0113 Keywords Enantiomers, Purification, Chiral Pharmaceuticals,

More information

YMC HILIC Columns for Polar Analytes

YMC HILIC Columns for Polar Analytes YMC HILIC Columns for Polar Analytes Polar Analytes Advantages In general, reliable applications in HPLC require a minimum retention factor (k ) of 2. In the widely used reversed phase methods polar compounds

More information

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity ACE CN-ES Combining CN polar selectivity with enhanced hydrophobicity Extended Spacer Extra Stability New stationary phase technology for UHPLC and HPLC separations Alternative polar selectivity for method

More information

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available ACE HILIC UHPLC and HPLC s For Reproducible Polar Analyte Separations Three HILIC Chemistries Available ACE HILIC s What is HILIC? Hydrophilic Interaction Liquid Chromatography (HILIC) was first described

More information

Chiral Screening for SFC and UHPLC with the Agilent 1260 Infinity II SFC/UHPLC Hybrid System

Chiral Screening for SFC and UHPLC with the Agilent 1260 Infinity II SFC/UHPLC Hybrid System Application Note Small Molecule Pharmaceutical Chiral Screening for SFC and UHPLC with the Agilent 16 Infinity II SFC/UHPLC Hybrid System Author Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

More information

LC Columns with Liquid Separation Cell Technology

LC Columns with Liquid Separation Cell Technology Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,

More information

Achiral SFC: Development of an Orthogonal SFC Method for Mometasone Furoate Impurity Analysis

Achiral SFC: Development of an Orthogonal SFC Method for Mometasone Furoate Impurity Analysis Achiral SFC: Development of an Orthogonal SFC Method for Mometasone Furoate Impurity Analysis Zhenyu Wang Merck Research Laboratories NJCG 2013 Outline SFC chronicle The journey of a half century Re-birth

More information

Rebaudioside a From Multiple Gene Donors Expressed in Yarrowia Lipolytica

Rebaudioside a From Multiple Gene Donors Expressed in Yarrowia Lipolytica Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016 Rebaudioside a From Multiple Gene Donors Expressed in Yarrowia Lipolytica This

More information

John P. McCauley and Rui Chen Waters Corporation, Milford, MA, USA INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEY WORDS

John P. McCauley and Rui Chen Waters Corporation, Milford, MA, USA INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEY WORDS Enantiomeric and diastereomeric separations of fragrance and essential oil components using the ACQUITY UPC 2 System with ACQUITY UPC 2 Trefoil Columns John P. McCauley and Rui Chen Waters Corporation,

More information

Studies on stereoselective separations of the azole antifungal drugs ketoconazole and itraconazole using HPLC and SFC on silica-based polysaccharides

Studies on stereoselective separations of the azole antifungal drugs ketoconazole and itraconazole using HPLC and SFC on silica-based polysaccharides SFC Dossier Studies on stereoselective separations of the azole antifungal drugs ketoconazole and itraconazole using HPLC and SFC on silica-based polysaccharides A. Thienpont 1, J. Gal 2, C. Aeschlimann

More information

column If you would like a subscription, or more information, please contact your nearest Waters Office.

column If you would like a subscription, or more information, please contact your nearest Waters Office. column Waters A Reprint from Spring 995 If you would like a subscription, or more information, please contact your nearest Waters Office. Check the Waters website for up-to-date information: http://www.waters.com

More information

Unequalled durability against water elution. % tr

Unequalled durability against water elution. % tr Unequalled durability against water elution 2 Revolutionary aqueous durability for aminopropyl phase 1 3 4 1. fructose (2.5mg/mL) 3. sucrose (2.5mg/mL) 500 hr 2. glucose 400 hr Aqueous to non-aqueous Normal

More information

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns Shuguang Li, Sky Countryman, and Erica Pike Phenomenex,

More information

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific Thermo Scientific GlycanPac AXR-1 Column Product Manual P/N: April, 2014 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXR-1 Columns GlycanPac AXR-1, 1.9 µm, Analytical, 2.1 x 150 mm (P/N

More information

Improved Pirkie Type 1 Amide Type: Asymmetric carbon atoms are bonded directly with CONH group

Improved Pirkie Type 1 Amide Type: Asymmetric carbon atoms are bonded directly with CONH group 1 sur 6 26/06/2013 14:16 Special Merits of SUMICHIRAL OA 1.The large number of theoretical plates of the columns offer high resolution. 2.The packing materials have chemical stability and the columns have

More information

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method International Journal of PharmTech Research CODEN (USA): IJPRIF ISSN : 0974-4304 Vol.5, No.4, pp 1736-1744, Oct-Dec 2013 Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin

More information

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior InertSustain Phenylhexyl A ew Second Choice Column to Change Chromatographic Behavior Providing Alternative Selectivity to C8 Phases InertSustain Phenylhexyl columns are bonded with phenylhexyl groups,

More information

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages APPLICATION NOTE 21671 Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages Authors Jon Bardsley, Thermo Fisher Scientific, Runcorn, UK Keywords Vanquish Flex, Acclaim PolarAdvantage

More information

Restek PAL SPME Fibers cat.#

Restek PAL SPME Fibers cat.# 1 Restek PAL SPME Fibers cat.# 27478 27483 Solid phase microextraction (SPME) fibers are used to extract organic compounds from solid, liquid, and vapor matrices onto a stationary phase that is bonded

More information

Phases Available Description Applications Additional Notes RCM-Monosaccharide (L19 packing)*

Phases Available Description Applications Additional Notes RCM-Monosaccharide (L19 packing)* Carbohydrate and Organic Acid Analysis Excellent resolution Wide range of selectivities Excellent column-to-column reproducibility Recommended alternative to Bio-Rad, Supelco Supelcogel and Waters Sugar-Pak

More information

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS Tanya Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Some of the most challenging methods

More information

Protect Your Mass Spec

Protect Your Mass Spec Protect Your Mass Spec Sample Preparation Solutions for Biological Samples www.phenomenex.com/bioms Dirty Samples Could be Costing You Money and Sensitivity Biological samples contain a wide variety of

More information

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis Product # LS-UR2-2.1x100 Ludger Document # LS-uR2-DMB-Guide-v2.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United Kingdom

More information

Macrocyclic Chiral Stationary Phases

Macrocyclic Chiral Stationary Phases Macrocyclic Chiral Stationary Phases Daniel W. Armstrong Robert A. Welch Professor University of Texas at Arlington Department of Chemistry and Biochemistry Arlington, TX 76019 Macrocycles in Separations

More information

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System Application Note Food, Hydrocarbon Processing Authors Michael Woodman Agilent Technologies,

More information

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Michael McGinley, Deborah Jarrett, and Jeff Layne Phenomenex, Inc., 411 Madrid Avenue, Torrance, CA 91 USA Aeris WIDEPORE

More information