World Renowned HPLC Media Reinvented for UHPLC!

Size: px
Start display at page:

Download "World Renowned HPLC Media Reinvented for UHPLC!"

Transcription

1 OMEGA World Renowned HPLC Media Reinvented for UHPLC! New. µm Staggering UHPLC Efficiencies and Performance Extreme Ruggedness and Mechanical Strength Perfect Complement to Kinetex Core-Shell Technology µm µm. µm Two Superb New Polar Selectivities for UHPLC and HPLC Polar C8 (. µm, µm, µm) PS C8 (. µm, µm, µm)

2 Enhanced with Years of Technology, Innovation, and Experience One of the world s leading HPLC brands, now enhanced for incredible UHPLC performance!. µm UHPLC columns culminate years of technological prowess, advancements, and innovation from Phenomenex! With astounding efficiency levels, highly versatile selectivities, and trusted accuracy, columns will take your UHPLC experience to a new level. Luna Omega UHPLC columns will boost your UHPLC instrumentation!

3 Why Luna Omega Should be in Your Lab? Omega Cutting-Edge UHPLC... p. Astounding Performance... p. Separation Muscle... p. Inert Foundation... p. Excellent Reproducibility... pp. 8-9 C8 C8 Selectivity... p. Utilizing Hydrophobicity... p. Polar C8 Polar C8 Selectivity... p. Enhanced Polar Retention... p. % Aqueous Stability... p. Polar and Non-polar Selectivity... p. Upgrading C8 Methods... p. Improving Existing Polar Methods... p. Polar Case Study: Catecholamines and PMETs... p. 8 Polar Case Study: ETG/ETS... p. 9 PS C8 PS C8 Selectivity... p. Enhanced Retention of Acids... p. Better Peak Shape for Bases... p. Excellent Loadability... p. Greater Method Flexibility... p. Improving Existing Basic Compound Methods... p. Reinvented Use Luna and Phases Together... p. UHPLC to HPLC to PREP Scalability... p. C8 and Polar C8 - Complementary Work Horses... pp. 8-9 Pairing With Core-Shell Technology... pp. - Column Lifetime... p. Sample Preparation... p. UHPLC Column Protection Guard Cartridge System... p. HPLC Column Protection Guard Cartridge System... p. Ordering Information... pp. -9 Phenomenex, Inc. All rights reserved.

4 Cutting-Edge. μm Silica Particle Luna is one of the most recognized HPLC brands on the market, delivering high efficiency, ruggedness, reproducibility and dependability for a wide range of analyses. The new. μm builds upon this legacy with an innovative yet rugged UHPLC silica particle architecture, designed and manufactured by Phenomenex based on more than years of applied knowledge, invention, and customer experience. Novel Design and Manufacturing Process Within the novel manufacturing process of. µm silica, we implement a proprietary processing technique to gain greater particle inertness, a stronger particle morphology, and more consistent porosity. Thermal Modified Pore Structure Consistent Porosity Most importantly, through our proprietary process, we eliminate micropores, further improving column efficiency, inertness, and reproducibility. Absence of Micropores C8 Polar C8 PS C8 TMS TMS Polar TMS TMS Polar + TMS TMS +

5 Astounding Performance The undeniably high efficiency levels found in each UHPLC column provide you with the potential of huge gains in method performance. While traditional silica and hybrid fully porous particles claim high performance, when compared to. μm, they drastically fall short and prevent UHPLC scientists from reaching their UHPLC potential. UHPLC Efficiency Comparison Luna Omega. µm C8 Thermo Scientific Hypersil GOLD.9 µm C8 Agilent ZORBAX Eclipse.8 µm XDB-C8 Thermo Scientific Syncronis. µm C8 Waters ACQUITY HSS.8 µm C8 Waters ACQUITY BEH. µm C8 AkzoNobel Kromasil.8 µm C8 ACE Excel µm C8 YMC -Triart.9 µm C8 Agilent ZORBAX.8 µm SB-C8,,,,,,, Efficiency (plates/meter) Dimension: x. mm Mobile Phase: Acetonitrile/Water (:) Flow Rate:. ml/min Temperature: Ambient Detection: nm System: ACQUITY UPLC

6 Separation Muscle Our industry leading bonding technologies in conjunction with high efficiency levels ensure excellent stationary phase coverage and improved separation power. Now, with. μm, you can turn difficult separations into resolution achievements. Luna Omega. µm C8.e.e.e.e.e.e.e 9.e 8.e.e.e.e.e.e.e.e Much Greater Resolution! min App ID 9 ACE Excel µm C8-AR.e.e.e.e.e.e.e 9.e 8.e.e.e.e.e.e.e.e. min App ID Agilent ZORBAX.8 µm XDB-C8.e.e.e.e.e.e.e.e.e.e.e.e.e.e.e. min App ID Columns:. µm C8 ZORBAX.8 µm XDB-C8 ACE Excel µm C8-AR Dimension: x. mm Mobile Phase: A:. % Formic Acid in Water B:. % Formic Acid in Methanol 9 Flow Rate:. ml/min Temperature: C Detection: MS/MS Sample:. Succinic acid. MMA. Glutaric acid. Methylsuccinate. Ethylmalonic acid. Hippuric acid. Homovanillic acid 8. Suberic acid

7 Inert Foundation UHPLC columns contain a unique silica modified using a proprietary, post-synthetic thermal treatment process to provide extraordinary mechanical strength and significantly greater inertness than traditional fully porous and hybrid materials. This greatly minimizes secondary interactions that negatively affect peak shape, allowing for greater method accuracy. Luna Omega. µm C Excellent Peak Shape App ID 8 min Waters ACQUITY BEH. µm C Poor Peak Shape App ID 8 min Thermo Scientific Hypersil GOLD.9 µm C Poor Peak Shape App ID 8 min Columns:. µm C8 ACQUITY BEH. µm C8 Hypersil GOLD.9 µm C8 Dimension: x. mm Mobile Phase: A:. % Formic Acid in Water B:. % Formic Acid in Acetonitrile Flow Rate:. ml/min Temperature: Ambient Detection: nm Sample:. Pindolol. Chlorpheniramine. Nortripytline. -Methyl--nitrobenzoic acid. -Methyl salicylaldehyde. Hexanophenone

8 Consistent Results C8 Batch-to-batch and column-to-column, Luna Omega media and columns are designed to be consistent and incredibly accurate tools for your analysis. Each batch and column are quality tested to ensure dependability and reproducibility. C8 Batch A Peak Capacity 8 App ID min C8 Batch B...8 Peak Capacity... 8 App ID min C8 Batch C Peak Capacity 8 App ID min Columns:. µm C8 Dimension: x. mm Part No.: B--AN Mobile Phase: A: Water B: Acetonitrile. 8 Flow Rate:. ml/min Temperature: Ambient Detection: nm Sample:. Estriol. Prednisolone. Hydrocortisone. Cortisone. Cortisone Acetate. -Hydroxycortisone. -Hydroxycortisone 8. Deoxycorticosterone 8

9 Consistent Results Polar C8 Just like Luna Omega C8, the Polar C8 is also stringently tested to make sure both batchto-batch and column-to-column quality stays at the highest level before it reaches your lab bench. Polar C8 Batch A Peak Capacity min App ID Polar C8 Batch B Peak Capacity QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV GL 9:8 min App ID Polar C8 Batch C min Peak Capacity App ID Columns:. µm Polar C8 Dimension: x. mm Part No.: B-8-AN Mobile Phase: A:. % Formic Acid in Water B:. % Formic Acid in Acetonitrile 9 Flow Rate:. ml/min Temperature: C Detection: nm Sample:. Uracil. Pindolol. Chlorpheniramine. Nortriptyline. -Methyl--nitrobenzoic acid. -Methyl salicylaldehyde. Hexanophenone 9

10 Selectivity Highlight C8 C8 Luna Omega C8 is an excellent first choice for chromatographers who are just starting method development or attempting to improve upon existing chromatographic results with other C8s. With its higher performance potential, excellent retention profile, and greater inertness, the C8 was designed to be the new all-purpose UHPLC solution for industries all over the world. Phase C8 Particle Size. µm Pore Size Å ph Range. - 8.* Surface Area m /g Carbon Load % Pressure Limit bar USP Listing L *ph stability under gradient conditions. ph stability is.- under isocratic conditions. TMS TMS Greater Retention and Better Results Higher efficiency levels in combination with excellent stationary phase coverage and greater particle inertness, translates to improved separation power for you. Now you can utilize the greater retention of Luna Omega C8 to tackle both easy and difficult separations.. µm C8 AU... min Waters ACQUITY BEH. µm C8 AU Peak Capacity 9 App ID 8 Peak Capacity App ID 8 Greater Peak Capacity and Retention Columns:. μm C8 ACQUITY BEH. μm C8 Dimension: x. mm Mobile Phase: A:. % Formic Acid in Water B:. % Formic Acid in Acetonitrile.. Flow Rate:. ml/min Temperature: Ambient Detection: nm Sample:. Acetaminophen. -Aminobenzoic Acid. -Hydroxybenzoic Acid. -Acetaminophenol. -Hydroxybenzoic Acid. Salicylicamide. Phenol 8. Benzoic Acid 9. Salicylic Acid... min

11 Small and Large Compound Mixtures Strong and focused hydrophobic retention, incredible efficiency and valuable inertness of Luna Omega C8 columns make them an excellent choice for small mixtures of compounds differing in hydrophobicity as well as large mixtures of compounds like impurity/degradation profiles and peptide maps. Phenols AU Columns:. µm C8 Dimension: x. mm Part No.: B--AN Mobile Phase: A:. % Formic Acid in Water B:. % Formic Acid in Acetonitrile. 9 Flow Rate:. ml/min Temperature: C Detection: nm Sample:. -Hydroxyphenol. Phenol. -Nitrophenol. -Methylphenol. -Methylphenol.,-Dimethylphenol. -Naphthol App ID min Synthetic Cannabinoids.e.e.e.e.e 9.e 8.e.e.e.e.e.e.e.e. 8 9 min Columns:. µm C8 Dimension: x. mm Part No.: B--AN Mobile Phase: A:. % Formic Acid in Water B:. % Formic Acid in Acetonitrile Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample:. JWH- Butanoic acid metabolite. JWH- -hydroxybutyl metabolite. JWH-8 Pentanoic acid metabolite. JWH- -hydroxybutyl metabolite. JWH-8 -hydroxypentyl metabolite. AM- -hydroxypentyl metabolite. JWH-8 -hydroxypentyl metabolite 8. AM-9 9. AM-. JWH-. JWH-8 App ID C8 OTC Drug - Pill Formulation Profile AU.... min Columns:. µm C8 Dimension: x. mm Part No.: B--AN Mobile Phase: A: mm Potassium Phosphate ph. B: Acetonitrile. 8 Flow Rate:. ml/min Temperature: Ambient Detection: nm Sample: OTC Drug Pill App ID Peptide Map Digested BSA.e9.e9 9.e8 8.e8.e8.e8.e8.e8.e8.e8.e8. App ID min Columns:. µm C8 Dimension: x. mm Part No.: D--AN Mobile Phase: A:. % Formic Acid in Water B:. % Formic Acid in Acetonitrile. Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample: Tryptic digest of BSA

12 Selectivity Highlight Polar C8 Polar C8 Luna Omega Polar C8 is a novel UHPLC stationary phase capable of providing a unique selectivity within a wide elution window and increased retention for both polar and non-polar analytes. The all-purpose C8 ligand provides hydrophobic interactions while a polar modified particle surface provides enhanced polar retention and also aqueous stability. These attributes make the Polar C8 an excellent choice for balanced retention of polar and hydrophobic compounds as well as to solely enhance retention of highly polar compounds. A C8, But Different Phase Polar C8 Particle Size. µm, µm, µm Pore Size Å ph Range. - 8.* Surface Area m /g Carbon Load 9 % Pressure Limit bar USP Listing L *ph stability under gradient conditions. ph stability is.- under isocratic conditions. Polar C8 is a uniquely modified C8-based chemistry that has been optimized to improve the performance of polar analyses. This new particle surface chemistry makes the Polar C8 applicable to all industries that utilize UHPLC for mixtures of polar and non-polar compounds. Polar TMS TMS Polar C8 silica surface Polar C8 silica surface TMS TMS TMS Polar Polar TMS

13 Greater Polar Retention With its polar modified surface, the Luna Omega Polar C8 offers UHPLC users enhanced separation power that can greatly improve resolution values for target compounds. Nicotine and Metabolites.8e.e.e.e.e.8e.e.e.e.e 8.e.e.e.e.e.e.e.8e.e.e.e.e 8.e.e.e.e + Catecholamines 8.e.e.e.e.e.e.e.e 8.e.e.e.e.e.e.e.e + Greater Retention Greater Retention. μm Polar C8 min min App ID 9 Waters CORTECS. µm C8 App ID 9. µm Polar C8 App ID 9 min Waters ACQUITY BEH. µm C8 App ID 9 min Columns:. µm Polar C8 CORTECS. µm C8 Dimension: x. mm Mobile Phase: A: mm Ammonium Formate with.% Formic Acid B: Acetonitrile with.% Formic Acid Columns:. µm Polar C8 ACQUITY BEH. µm C8 Dimension: x. mm Mobile Phase: A: Water with.% Formic Acid B: Acetonitrile with.% Formic Acid.. 9 Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample:. Nornicotine. -Hydroxycotinine. Nicotine. Cotinine. Anabasine 9 Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample:. Norepinephrine. Epinephrine. Normetanephrine. Dopamine. Metanephrine Polar C8

14 % Aqueous Stability Polar C8 % of Initial Retention Time No Stationary Phase Collapse Traditional C8 phases are known to collapse under % aqueous conditions, causing retention loss of compounds and a method development headaches. That is why an advanced proprietary bonding technology was used for the Luna Omega Polar C8 in order to ensure aqueous stability. The graph below displays the excellent stability of Polar C8 in % aqueous buffer conditions for over weeks. Aqueous Stability of Polar C8 % % 8% % % % % Adenine G--MP Thymine Columns:. µm Polar C8 Dimension: x. mm Part No.: B-8-AN Mobile Phase: mm Ammonium Formate with. % Formic Acid Flow Rate:. ml/min Temperature: C Detection: nm Sample:. Adenine. Guanosine--Monophosphate. Thymine App ID Duration of Exposure Day Day Nucleosides in % Aqueous Conditions Use % aqueous conditions for the greatest polar acid/base retention.. µm Polar C8 App ID 8 min Waters ACQUITY BEH. µm C8 App ID 8 min Columns:. µm Polar C8 ACQUITY BEH. µm C8 Dimension: x. mm Mobile Phase: mm Ammonium Formate ph. Flow Rate:. ml/min Temperature: C Detection: 8 nm Sample:. Thiourea. -Fluorocytosine. Guanosine--Monophosphate. Adenine. Thymine

15 Versatility Hydrophobic and Polar Interactions Combined retention of polars and non-polars by the Luna Omega Polar C8 gives you an incredible range of potential success when working with methods from just about any industry. Here we illustrate the usefulness of these interaction mechanisms with water soluble vitamins from drink and tablet, a multi-compound antibiotic screen, and a UHPLC/MS/MS separation of algal toxins. Water Soluble Vitamins Algal Toxins (EPA ).e.8e.e.e.e.e 8.e.e.e.e.e.e.e.e.e.e.e.e.e.e.e Columns:. µm Polar C8 Dimension: x. mm Part No.: B-8-AN Mobile Phase: A: mm Ammonium Formate with. % Formic Acid B: Acetonitrile with. % Formic Acid. 9 Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample:. Pyridoxamine. Thiamine. Nicotinic acid. Pyridoxine min Vitamin Tablet min. Pantothenic acid. Folic acid. Riboflavin Standards App ID 8 min Vitamin Enriched Drink App ID 8 App ID 9 Relative Abundance RT:. -. Uracil-d RT:.9 AA: 9 SN: Anatoxin-a RT:.8 AA: SN: RT:.9 AA: 8 SN: RT:. AA: SN: RT:.8 AA: 8 SN: L-Phenylalanine-d Cylindrospermopsin RT:. AA: 9 SN: RT: 8. AA: 89 SN: 9 RT:. AA: 898 SN: RT: 9. AA: SN: NL:.E TIC F: + c ESI SRM ms. [ ] MS ICIS Testb NL:.E TIC F: + c ESI SRM ms. [ ] MS ICIS Testb RT: 9. AA: SN: NL:.E TIC F: + c ESI SRM ms. [.99-.] MS ICIS Testb NL:.8E TIC F: + c ESI SRM ms. [ ] MS ICIS Testb 8 min Find complete method at Phenomenex.com Application ID: 9 Polar C8 Antibiotic Screen.e.e.e.e App ID 8 min Columns:. µm Polar C8 Dimension: x. mm Part No.: B-8-AN Mobile Phase: A: mm Ammonium Formate with. % Formic Acid B: Acetonitrile with. % Formic Acid.. 9 Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ). Sulfaguanidine. Sulfadiazine. Cefalexin. Lincomycin. Amoxicillin. Sulfathiazole. Sulfapyridine 8. Cefazolin 9. Sulfamerazine. Ciprofloxacin. Sulfamethazine. Sulfamonomethoxine. Enrofloxacin. Difloxacin. Chlortetracycline. Sulfamethoxazole. Florfenicol 8. Sulfaquinoxaline 9. Oxacillin. Sulfadimethoxine

16 Highly Useful Alternative to the Common C8 Polar C8 Unlike traditional UHPLC C8 stationary phases, the polar and hydrophobic versatility of Polar C8 combined with its high efficiency levels allow for enhanced separation power. Combine that with % aqueous stability and you can really see how the Luna Omega Polar C8 can potentially lead to more separation success compared to traditional C8 columns. Ketotifen Impurity Profile Beta Blockers µm Polar C8 min Thermo Scientific Hypersil GOLD.9 µm C8 min min Greater retention and resolution of impurities App ID App ID. µm Polar C8 App ID Agilent ZORBAX.8 µm SB-C8 App ID min Columns:. µm Polar C8 Hypersil GOLD.9 µm C8 Dimension: x. mm Mobile Phase: A: Water with. % Formic Acid B: Acetonitrile with. % Formic Acid.. Flow Rate:. ml/min Temperature: Ambient Detection: nm Sample: Ketotifen Clean, sharp peaks and excellent resolution Columns:. µm Polar C8 ZORBAX.8 µm SB-C8 Dimension: x. mm Mobile Phase: A: mm Postassium Phosphate ph. B: Acetonitrile. Flow Rate:. ml/min Temperature: Ambient Detection: 8 nm Sample:. Atenolol. Pindolol. Timolol. Metoprolol. Labetolol. Propranolol

17 Excellent Alternative to Existing Polar Columns Luna Omega Polar C8 is an incredibly high performing UHPLC column with a unique selectivity profile that can be used to upgrade existing methods or jumpstart new method development. Realize lower limits of detection with the increase in sensitivity levels or just utilize the efficiency gains to help resolve closely eluting peaks. Mycotoxins Screen.e.e.e.e.e.e + 8 min Conditions same for all columns: Columns:. µm Polar C8 ACQUITY HSS.8 µm T Dimension: x. mm Mobile Phase: A: Water with. % Formic Acid B: Acetonitrile with. % Formic Acid. 9. µm Polar C8 App ID.e.e.e.e.e.e + min Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample: Positive Mode (ESI+). -Acetyldeoxynivalenol. Aflatoxin G. Aflatoxin G. Aflatoxin B. Aflatoxin B. Aflatoxin M. HT Toxin 8. T Toxin 8 Waters ACQUITY HSS.8 µm T App ID Polar C8 SAMHSA Workplace Drug Testing Screen.8e.e.e.e.e 8.e.e.e.e. µm Polar C8 App ID 88 min.8e.e.e.e.e 8.e.e.e.e Waters ACQUITY HSS.8 µm T App ID 89 min Conditions same for all columns: Columns:. µm Polar C8 ACQUITY HSS.8 µm T Dimension: x. mm Mobile Phase: A: Water with. % Formic Acid B: Acetonitrile with. % Formic Acid. Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample:. Morphine. Codeine. Amphetamine. MDA. Methamphetamine. -MAM. MDMA 8. MDEA 9. BZE. PCP. THC-COOH. THC

18 Polar Case Study Catecholamines and Metabolites Polar C8 Current analytical tests for pheochromocytoma (tumor of chromaffin cells of the adrenal medulla) focus on measuring for elevated levels of plasma free metanephrine and normetanephrine, which are continually secreted by the tumors. Supplementary methods also analyze the metabolites of metanephrine and normetanephrine, including vanillylmandelic acid. With such a range of polar compounds, the aqueous stability and enhanced polar retention of the Luna Omega Polar C8, both play an strong part in generating excellent separation between all these important analytes. Catecholamines (ESI+) 8.e.e.e.e.e.e.e.e PMETs from Plasma (ESI+) 8.e.e.e.e.e.e.e.e 9 App ID 9 min App ID 9 min Catecholamine Metabolites (ESI-).e Flow Rate:. ml/min.e 9.e.e.e 8 App ID 9 min Conditions for all columns unless otherwise noted: Columns:. µm Polar C8 Dimension: x. mm Part No.: D-8-AN Mobile Phase: A: Water with. % Formic Acid B: Acetonitrile with. % Formic Acid. Flow Rate:. ml/min Temperature: C 9 Detection: MS/MS (SCIEX API ) Sample: Positive Mode (ESI+). Norepinephrine. Epinephrine. Normetanephrine. Dopamine. Metanephrine. -Methoxytyramine Negative Mode (ESI-). Vanillylmandelic acid (VMA) 8. -Hydroxyindoleacetic acid (-HIAA) 9. Homovanillic acid (HVA) Recommended Sample Preparation Method Product: Strata -X-CW Microelution 9-Well Plate Part No.: 8M-S-GA Condition: µl Methanol Equilibrate: µl Water Load Sample: µl Plasma diluted with µl Water Wash : µl Water Wash : µl : Acetonitrile/IPA Dry for minute at Hg to remove excess wash solvent Elute: x µl 8: Acetonitrile/Water with % Formic acid 8

19 Polar Case Study ETG/ETS Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are metabolites of ethanol that are used by analytical laboratories to detect recent ethanol ingestion. In this application, the Luna Omega Polar C8 provides excellent separation between EtG and EtS, along with valuable separation from a urine interference peak and where other matrix suppression is common. Additionally, the high efficiency levels provided by the. µm allow for a highly sensitive, yet rapid method. ETG and ETS from Urine Sample.e.e.e.e.8e.e.e.e.e.8e.e.e.e 8.e.e.e.e.8e.e.e.e.e.8e.e.e.e 8 ETS ETG Overlaid XIC App ID 9 XIC to ETS min App ID 9 min Polar C8 9 8 XIC to ETG App ID 9 min Columns:. µm Polar C8 Dimension: x. mm Part No.: D-8-AN Mobile Phase: A: mm Ammonium Formate with. % Formic Acid B: Acetonitrile with. % Formic Acid. Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample: Negative Mode (ESI-). Urine interference. ETS. ETG 9

20 Selectivity Highlight PS C8 PS C8 Luna Omega PS C8 is a unique mixed-mode stationary phase that provides incredibly useful polar and non-polar retention. The surface of the PS C8 contains a positive charge which aids in the retention of acidic compounds through ionic interactions, while the C8 ligand promotes general reversed phase retention. This mixed-mode selectivity allows for greater separation between compounds with varying functional groups. Phase PS C8 Particle Size. µm, µm, µm Pore Size Å ph Range. - 8.* Surface Area m /g Carbon Load 9 % Pressure Limit bar USP Listing L *ph stability under gradient conditions. ph stability is.- under isocratic conditions. + TMS TMS + A C8, But More Positive PS C8 has been fine-tuned and manufactured by Phenomenex to provide a mixed selectivity that is highly useful for method development involving either combinations of polars and non-polars, or just one single compound class with small changes in functional groups. C8 silica surface PS C8 silica surface TMS TMS + TMS + + TMS

21 Enhanced Retention of Acids With its positive surface (PS) the Luna Omega PS C8 provides valuable increase in retention of acids through ionic/polar interactions. In addition, the C8 ligand also stimulates hydrophobic retention that greatly promotes increased resolution between analytes of interest. MMA and Succinic Acid.e.8e.e.e.e.e 8.e.e.e.e.e.e.e.e Organic Acids.e.e.e 9.e 8.e.e.e.e.e.e.e.e.e.e.e 9.e 8.e.e.e.e.e.e.e.e min 8 Waters ACQUITY HSS.8 μm T min 9. μm PS C8 min Greater Retention and Resolution Increased Resolution 8 App ID ACE Excel μm C8-AR App ID 9. µm PS C8 App ID 8 min 9 App ID 89 Columns:. μm PS C8 ACE Excel μm C8-AR Dimension: x. mm Mobile Phase: A: Water with. % Formic Acid B: Acetonitrile with. % Formic Acid Columns:. μm PS C8 ACQUITY HSS.8 μm T Dimension: x. mm Mobile Phase: A: Water with.% Formic Acid B: Acetonitrile with.% Formic Acid.. Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample:. Succinic acid. MMA Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample:. Lactic acid. Succinic acid. MMA. Glutaric acid. Ethylmalonic acid. Methyl succinate. Hippuric acid 8. Suberic acid 9. Sebacic acid PS C8

22 Better Peak Shape for Bases PS C8 AU AU While traditional alkyl phases are prone to show tailing for basic compounds because of secondary interactions occurring at the silica surface, the surface of the Luna Omega PS C8 was designed with positive charges that serve to repel strong basic species and consistently display sharp peak shape. Pharmaceutical Compound Mixture Better Peak Shape Waters ACQUITY BEH. μm C8. μm PS C8 App ID min App ID min Columns:. μm PS C8 ACQUITY BEH. μm C8 Dimension: x. mm Mobile Phase: A: Water with.% Formic Acid B: Acetonitrile with.% Formic Acid. 8 9 Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample:. Uracil. Pindolol. Chlorpheniramine. Nortriptyline. -Methyl--nitrobenzoic acid. -Methyl salicylaldehyde. Hexanophenone Intact Insulin.e.e.e.e.e.e.e.e.e.e.e.e Better Peak Shape. µm PS C8 Thermo Scientific Hypersil GOLD.9 µm C8 Agilent ZORBAX.8 µm SB-C8 min App ID 9, 9 and 9 Columns:. μm PS C8 Hypersil GOLD.9 μm C8 ZORBAX.8 µm SB-C8 Dimension: x. mm Mobile Phase: A: Water with.% Formic Acid B: Acetonitrile with.% Formic Acid. 8 Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample: Insulin

23 Excellent Loadability AU The combination of great surface coverage and novel surface chemistry results in narrow peak shapes for an extended amount of sample loaded on the Luna Omega PS C8. This can visually be seen in the examples below where the excellent peak shape at different loads is kept relatively constant on the PS C8, while more conventional UHPLC columns show tailing and much greater peak broadening as more sample is loaded. Amitriptyline µg Load mau 8 Amitriptyline Loading Study μm PS C8 Supelco Titan.9 µm C8 AMT HALO µm C8... min Better Peak Shape Over All Loads App ID min. µm PS C8 App ID Columns:. μm PS C8 Titan.9 µm C8 HALO µm C8 Dimension: x. mm Mobile Phase: Water with.% Formic Acid / Acetonitrile with.% Formic Acid (8:) Flow Rate:. ml/min Temperature: C Detection: nm Sample: Amitriptyline Columns:. μm PS C8 ACQUITY BEH. μm C8 Dimension: x. mm Mobile Phase: A: Water with.% Formic Acid B: Acetonitrile with.% Formic Acid Flow Rate:. ml/min Temperature: C Detection: nm Sample: Amitriptyline 8 PS C8 AU Waters ACQUITY BEH. μm C8... min App ID 8 Peak Width at % PS C8 and Competitors x. mm µg on column App ID 9 Better Peak Shape Over All Loads Luna. µm PS C8 HALO µm C8 ACQUITY BEH. µm C8 Hypersil GOLD.9 µm C8

24 Method Development Flexibility PS C8 The combination of available Luna Omega stationary phases represent an outstanding tool set for the separation of acids, bases, neutrals or mixtures. Use the C8 to focus on hydrophobic interactions or the mixedmode functionality of the Polar C8 and PS C8 to get enhanced retention of both polars and non-polars. Pharmaceutical Drug Impurity Profile Useful alternative peak elution order. μm PS C8 8 9 min App ID. μm Polar C8 App ID 8 9 min μm C8 8 9 min App ID Columns:. μm PS C8. μm Polar C8. μm C8 Dimension: x. mm Mobile Phase: A: Water with.% Formic Acid B: Acetonitrile with.% Formic Acid Flow Rate:. ml/min Temperature: C Detection: nm Sample: Proprietary drug impurity profile

25 Improving Existing Basic Compound Methods Luna Omega PS C8 is a brilliant UHPLC stationary phase with a distinctive selectivity profile that can spur new method development. At the same time, this versatile phase can also upgrade existing methods by way of increases in sensitivity and efficiency levels to help resolve closely eluting peaks. Peptides by LC/MS.e.e.e.e 9.e 8.e.e.e.e.e.e.e.e.e.e.e.e 9.e 8.e.e.e.e.e.e.e.e Beta-Blockers μm PS C8 -. min μm PS C8 Waters ACQUITY CSH. µm C8 min -. min App ID App ID.e.e.e.e 9.e 8.e Better Sensitivity Luna Omega.e min.e ACQUITY.e CSH.e.e.e.e App ID App ID App ID Columns:. μm PS C8 ACQUITY CSH. µm C8 Dimension: x. mm Mobile Phase: A: Water with.% Formic Acid B: Acetonitrile with.% Formic Acid min Waters CORTECS. μm C8+. 9 Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample:. Angiotensin II. Met-Enkephalin. Leu-Enkephalin Columns:. μm PS C8 CORTECS. μm C8+ Dimension: x. mm Mobile Phase: A: mm Ammonium Formate ph. B: Acetonitrile Flow Rate:. ml/min Temperature: C Detection: 8 nm Sample:. Pindolol. Timolol. Metoprolol. Labetolol. Propranolol PS C8

26 Use Luna and Phases Together Combine the new Luna Omega µm Polar C8 and PS C8 with Luna µm phases like Phenyl-Hexyl and PFP() to expand your HPLC method development choices or try different separation modes with Luna phases such as Silica(), NH, and HILIC. Ezetimibe Degradation Profile mau 8 - mau Luna μm PFP() min μm Polar C8 App ID 9 Columns: Luna μm PFP() μm Polar C8 Luna μm Phenyl-Hexyl Luna μm C8() Dimension: x. mm Mobile Phase: A: Water B: Acetonitrile Flow Rate: ml/min Temperature: C Detection: nm Sample: Ezetimibe Degradation Profile 8 App ID 98 - min mau Luna μm Phenyl-Hexyl 8 App ID 99 - min mau Luna μm C8() 8 App ID 8 - min

27 UHPLC to HPLC to PREP Scalability With direct selectivity scalability from Luna Omega. µm to µm you can fluidly transfer methods from UHPLC platforms to HPLC and preparative instrumentation. Additionally, you can easily go in reverse and use a. µm to analyze fractions taken from a µm preparative column. Direct Scalability. µm to µm mau. μm Polar C8 μm Polar C8 min App ID Columns:. μm Polar C8 µm Polar C8 Dimension: x. mm Mobile Phase: A: Water with.% Formic Acid B: Acetonitrile with.% Formic Acid 9 Flow Rate:. ml/min Temperature: C Detection: nm Sample:. Uracil. Pindolol. Chlorpheniramine. Nortriptyline. -Methyl--nitrobenzoic acid. -Methyl salicylaldehyde. Hexanophenone UHPLC to HPLC to PREP Analyze Prep Fractions via UHPLC UHPLC Scout min Dimension: x. mm Flow Rate:. ml/min Preparative Purification mau 8 Dimension: x. mm Flow Rate: ml/min 8 App ID App ID Optimized HPLC mau 8 8 Dimension: x. mm Flow Rate:. ml/min App ID Conditions for all columns (as noted): Columns: μm PS C8 Mobile Phase: A: Water with.% TFA B: Acetonitrile with.% TFA Temperature: C Detection: nm Sample:. Impurity. Proprietary API. Impurity 9

28 Complementary UHPLC Work Horses Combine the versatile interaction mechanisms of the Luna Omega C8 and Polar C8 to achieve successful separations and improve upon challenging existing methods. Natural Cannabinoids mau mau µm Polar C8 8 9 min Greater hydrophobic retention App ID 8. µm C8 App ID 8 Columns:. µm Polar C8. µm C8 Dimension: x. mm Mobile Phase: A: mm Ammonium Formate ph. B: Acetonitrile. 9 9 Flow Rate:. ml/min Temperature: C Detection: nm Sample:. CBDV. Cannabidiol. CBG. Cannabidolic Acid. CBG-A. Cannabinol. Delta 9 THC 8. Delta 8 THC 9. CBC. THCA-A 8 9 min Influence Selectivity with % Aqueous Stability and Polar Interactions Intact Peptides mau mau. µm Polar C8. µm C8 App ID min Use the % aqueous stability of polar C8 to aid in better retention of polar compounds App ID 9 Conditions for all columns except where noted: Columns:. µm Polar C8. µm C8 Dimension: x. mm Mobile Phase: A: Water with. % TFA B: Acetonitrile with. % TFA Flow Rate:. ml/min Temperature: C Detection: nm Sample:. Gly-Tyr. Val-Tyr-Val. Met-Enkephalin. Leu-Enkephalin. Angiotensin II min 8

29 Complementary UHPLC Work Horses For the analysis of a large screen or mixture of compounds, you can benefit greatly from utilizing both the Luna Omega C8 and Polar C8 during method development. The strong focused hydrophobic retention of the C8 will provide excellent non-polar retention and separation, while the Polar C8 provides a complementary hydrophobic/polar combined selectivity that can retain and separate typically early eluting compounds Tryptic Digest - Peptide Map of BSA.e9.e9.e9.e9 9.e8 8.e8.e8.e8.e8.e8.e8.e8.e8 8. µm Polar C min App ID 99 Greater resolution of early, more polar eluters.e8.e8 8.e8.e8.e8. µm Polar C8 App ID.e8.e8 8.e8.e8.e8. µm C8 App ID.e8.e8 8 9 min 8 9 min Better resolution of more hydrophobic compounds.e9.e9 9.e8 8.e8.e8.e8.e8.e8.e8.e8.e8.. µm C8 min App ID Conditions same for all columns: Columns:. µm C8. µm Polar C8 Dimension: x. mm Mobile Phase: A:. % Formic Acid in Water B:. % Formic Acid in Acetonitrile. Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample: Digested BSA 9

30 + Kinetex = Happy UHPLC Increase your method development options by screening a combination of core-shell and fully porous selectivities. Natural Cannabinoids mau mau mau Excellent resolution 8 9 min Faster analysis with similar peak order Alternative peak elution order Luna Omega. µm Polar C8 8 9 min App ID 8 App ID 8 App ID 8 Kinetex. µm F Kinetex. µm Biphenyl TMS TMS Polar Polar F F F F F TMS TMS F TMS TMS Biphenyl 8 9 min Columns:. µm Polar C8 Kinetex. µm Biphenyl Kinetex. µm F Dimension: x. mm Mobile Phase: A: mm Ammonium Formate ph. B: Acetonitrile. 9 9 Flow Rate:. ml/min Temperature: C Detection: nm Sample:. CBDV. Cannabidiol. CBG. Cannabidolic Acid. CBG-A. Cannabinol. Delta 9 THC 8. Delta 8 THC 9. CBC. THCA-A

31 + Kinetex = Happy UHPLC Combining orthogonal UHPLC particle morphologies and selectivities like the C8, Kinetex Biphenyl, and Kinetex EVO C8 will drastically increase your probability of separation success! Morphine Drugs of Abuse Analysis Luna Omega. µm C8 ph. ADVANTAGE Excellent inertness and strong hydrophobic retention Kinetex. µm Biphenyl Kinetex. µm EVO C8 App ID App ID min ph. ADVANTAGE Extra aromatic (pi-pi) and dipole-dipole retention App ID min ph 8. ADVANTAGE Excellent peak shape and retention of bases at high ph min Conditions for all columns except where noted: Columns:. µm C8 Kinetex. µm Biphenyl Kinetex. µm EVO C8 Dimension: x. mm Mobile Phase:. µm C8 and Kinetex. µm Biphenyl A:. % Formic Acid in Water B:. % Formic Acid in Acetonitrile Kinetex. µm EVO C8 A: mm Ammonium Bicarbonate ph B: Acetonitrile. 9 9 Flow Rate:. ml/min Temperature: C Detection: MS/MS (SCIEX API ) Sample: Drugs of Abuse

32 Excellent Lifetime. µm media was designed to be durable and withstand the high pressures and rigors of UHPLC work in combination with providing excellent performance. Accelerated Lifetime Study.% 9.% 8.%.% % Increase over Initial Backpressure.%.%.%.%.%.%.% Injection Cycle App ID Luna Omega. µm C8 (AVG) Waters ACQUITY BEH. µm C8 (AVG) Conditions same for both columns: Columns:. µm C8 ACQUITY BEH. µm C8 Dimension: x. mm Mobile Phase: A:. % Formic Acid in Water B:. % Formic Acid in Acetonitrile. Flow Rate:. ml/min Temperature: C Detection: nm Sample: Protein Matrix 9 Extend UHPLC Column Lifetime Even More with SecurityGuard ULTRA See page for details

33 Sample Preparation Further Improve Lifetime with Sample Preparation Both UHPLC instrumentation and columns can benefit from consistent removal of microparticulates/contaminants that may appear in solvents, samples or specific matrices. Over time these problematic compounds can build up on instrumentation and columns, leading to the need for costly maintenance and repair. Strata-X polymeric SPE, Novum liquid extraction, and Phenex syringe filters are excellent options to try. Polymeric SPE Very targeted form of sample preparation that allows you to isolate your analyte of interest while removing any interfering compounds in your sample StrataX novum simplified liquid extraction Remove interferences such as proteins, phospholipids, salts, and more in a quick and simple procedure Novum Convenient and inexpensive way to remove particulates from LC samples Phenex

34 Protect any UHPLC Column Protect your UHPLC column, including Luna Omega. µm columns, from damaging contaminants and microparticulates with the SecurityGuard ULTRA guard cartridge system! Simple to use Extend column lifetime Pressure rated to, psi (,8 bar) Fits virtually all manufacturers columns. to. mm ID ULTRA UHPLC Column Protection From Injector SecurityGuard ULTRA UHPLC Column to Detector Holder Cartridge Contaminants Trapped SecurityGuard ULTRA Guard Cartridge System (Cartridge connected to Holder) Compounds of Interest Contaminants and Particulates Frit * Cartridge schematic not drawn to scale Material Chamber See it in action:

35 Protect any HPLC Column The easiest way to extend column performance is to prevent contaminants and particulates from getting into your Luna Omega µm column with the SecurityGuard Standard guard cartridge system. Protects and extends column lifetimes Virtually no change in chromatography Simple to use HPLC Column Protection From Injector Fingertight connection to virtually any female inverted endfitting worldwide 9 Cartridge Replaced 8 Guard Cartridge System HPLC Column to Detector A B Contaminants Trapped A B Cutaway view showing cartridge can be easily inspected for contaminants Universal Fingertight connection to HPLC column no wrenches required contaminants compounds of interest Backpressure (Bar) - Injections Column returns to initial backpressure Accelerated lifetime test using endogenous biomolecule matrix on a µm x. mm column with SecurityGuard cartridges. Backpressure values represent additional backpressure contributed by SecurityGuard. The SecurityGuard analytical cartridge holder (patented) directly finger-tightens into virtually any manufacturer s column endfitting. Contaminants are retained by an inexpensive disposable cartridge instead of damaging your valuable HPLC and SFC column investment. Simply replace SecurityGuard cartridges instead of your expensive columns. In this graph, once the expired SecurityGuard cartridge was replaced, the pressure immediately dropped and the column performance was restored allowing for extended column use. See it in action:

36 Luna and Column Characteristics Luna Omega Phases Description Particle Sizes (µm) Pore Size (Å) Surface Area (m /g) Carbon Load (%) ph Stability C8 C8 ligand optimized for improved * peak shape Polar C8 Enhanced selectivity/retention for.,, * polar analytes without diminishing useful non-polar retention PS C8 Mixed-mode functionality offering.,, * enhanced retention of polar acids along with improved peak shape for strong bases * ph stability under gradient conditions. ph stability is. - under isocratic conditions. Reversed Phase Normal Phase HILIC IEX Luna Phases Description Particle Sizes (µm) Silica() Unbonded silica,,, -PREP, Pore Size (Å) Surface Area (m/g) Carbon Load (%) ph Stability. -. C Carbon ligand, * C8() C8() C8 ligand optimized for improved peak shape C8 ligand optimized for improved peak shape,,, -PREP,.,,,, -PREP, * * CN Versatile CN phase,,.. -. NH Rugged and reproducible NH,, Phenyl-Hexyl Phenyl phase attached to C (hexyl) ligand,,, -PREP, * SCX Benzene sulfonic acid, Binding. -. Capacity:. meq/g HILIC Reproducible, cross-linked diol, PFP() Pentafluorophenyl with a C (propyl) linkage, * ph range is. - 9 under gradient conditions. ph range is. - under isocratic conditions. Reversed Phase Normal Phase HILIC IEX Find more information on all these phases online at

37 Ordering Information Buy Luna Omega Now. μm Microbore Columns (mm) Phases x. x. x. Polar C8 B-8-A D-8-A F-8-A C8 B--A D--A F--A SecurityGuard. μm Minibore Columns (mm) ULTRA Cartridges Phases x. x. x. x. /pk Polar C8 A-8-AN B-8-AN D-8-AN F-8-AN AJ-9 PS C8 A--AN B--AN D--AN F--AN AJ-98 C8 A--AN B--AN D--AN F--AN AJ-9 for. mm ID SecurityGuard µm Minibore and MidBore Columns (mm) Cartridges (mm) Phases x. x. x. x. x. x. x. x.* / pk Polar C8 A--AN B--AN D--AN F--AN B--Y D--Y F--Y AJ- PS C8 A-8-AN B-8-AN D-8-AN F-8-AN B-8-Y D-8-Y F-8-Y AJ- for ID:.-. mm SecurityGuard µm Analytical Columns (mm) Cartridges (mm) Phases x. x. x. x. x.* / pk Polar C8 B--E D--E F--E G--E AJ- PS C8 B-8-E D-8-E F-8-E G-8-E AJ- for ID:.-8. mm SecurityGuard µm Minibore and MidBore Columns (mm) Cartridges (mm) Phases x. x. x. x. x. x. x. x.* / pk Polar C8 A--AN B--AN D--AN F--AN B--Y D--Y F--Y AJ- PS C8 A--AN B--AN D--AN F--AN B--Y D--Y F--Y AJ- for ID:. -. mm SecurityGuard μm Analytical Columns (mm) Cartridges (mm) Phases x. x. x. x. x.* / pk Polar C8 B--E D--E F--E G--E AJ- PS C8 B--E D--E F--E G--E AJ- for ID:.-8. mm SecurityGuard μm Axia Packed Preparative Columns (mm) Cartridges (mm) Phases x. x. x x x x.** x. /ea /ea Polar C8 F--P-AX G--P-AX F--U-AX G--U-AX G--V-AX AJ- AJ- PS C8 F--P-AX G--P-AX F--U-AX G--U-AX G--V-AX AJ-8 AJ-9 for ID:. mm for ID: mm SecurityGuard ULTRA Cartridges require holder, Part No.: AJ-9 * SecurityGuard Analytical Cartridges require holder, Part No.: KJ-8 ** PREP SecurityGuard Cartridges require holder, Part No.: AJ-8 PREP SecurityGuard Cartridges require holder, Part No.: AJ-8 If Luna analytical columns do not provide at least an equivalent separation as compared to a competing column of the same particle size, similar phase and dimensions, return the column with comparative data within days FOR A FULL REFUND. Phenomenex l WEB:

38 Ordering Information Buy Luna Now SecurityGuard μm Microbore and Minibore Columns (mm) Cartridges (mm) Phases x. x. x. x. x. x. x. x.* / pk Silica() A--B B--B F--B G--B AJ- C A--B B--B F--B AJ-9 C8 () F-9-A A-9-B B-9-B F-9-B G-9-B AJ-89 C8 () B--A F--A G--A A--B B--B F--B G--B AJ-8 CN B--B F--B AJ- Phenyl-Hexyl B--A A--B B--B F--B G--B AJ- NH B-8-A F-8-A A-8-B B-8-B F-8-B G-8-B AJ- PFP() A-8-B B-8-B F-8-B AJ-8 for ID:. -. mm SecurityGuard μm MidBore Columns (mm) Cartridges (mm) Phases x. x. x. x. x.* / pk Silica() B--Y F--Y AJ- C F--Y AJ-9 C8() A-9-Y B-9-Y F-9-Y G-9-Y AJ-89 C8() A--Y B--Y F--Y G--Y AJ-8 CN B--Y F--Y G--Y AJ- Phenyl-Hexyl B--Y F--Y G--Y AJ- NH B-8-Y F-8-Y G-8-Y AJ- SCX F-98-Y AJ-8 HILIC F--Y AJ-88 PFP() B-8-Y F-8-Y AJ-8 for ID:. -. mm SecurityGuard μm Analytical Columns (mm) Cartridges (mm) Phases x. x. x. x.* / pk Silica() B--E AJ-8 C B--E AJ-9 C8() A-9-E B-9-E C-9-E AJ-9 C8() A--E B--E C--E AJ-8 CN A--E B--E C--E AJ- Phenyl-Hexyl A--E B--E AJ- NH B-8-E AJ- SCX B-98-E AJ-8 HILIC AJ-89 PFP() B-8-E AJ-8 for ID:.-8. mm *SecurityGuard Analytical Cartridges require holder, Part No.: KJ-8 Find. µm and µm Luna column options at 8 Phenomenex l WEB:

39 Ordering Information Buy Luna Now μm Analytical and Semi-Prep Columns (mm) SecurityGuard Cartridges (mm) Phases x. x. x. x x. * x / pk / pk Silica() D--E F--E G--E G--N AJ-8 AJ- C D--E F--E G--E G--N AJ-9 AJO- C8() D-9-E F-9-E G-9-E G-9-N AJ-9 AJ- C8() D--E F--E G--E G--N AJ-8 AJ- CN D--E F--E G--E G--N AJ- AJ- Phenyl-Hexyl D--E F--E G--E G--N AJ- AJ- NH D-8-E F-8-E G-8-E G-8-N AJ- AJ- SCX D-98-E F-98-E G-98-E G-98-N AJ-8 AJ-9 HILIC D--E F--E G--E G--N AJ-89 AJ-89 PFP() D-8-E F-8-E G-8-E G-8-N AJ-8 AJ-8 for ID: mm 9 - mm SecurityGuard μm Axia Packed Preparative Columns (mm) Cartridges (mm) Phases x. x. x. x. x. ** /ea Silica() D--P-AX F--P-AX G--P-AX AJ-9 C G--P-AX C8() F-9-P-AX G-9-P-AX AJ-8 C8() B--P-AX D--P-AX F--P-AX G--P-AX AJ-89 CN G--P-AX AJ-8 Phenyl-Hexyl D--P-AX F--P-AX G--P-AX AJ-8 NH F-8-P-AX G-8-P-AX AJ-8 PFP() D-8-P-AX F-8-P-AX G-8-P-AX AJ-8 HILIC D--P-AX F--P-AX G--P-AX AJ-889 for ID: 8-9 mm SecurityGuard μm Axia Packed Preparative Columns (mm) (cont'd) Cartridges (mm) Phases x x x x /ea Silica() G--U-AX AJ-8 C8() D-9-U-AX AJ-8 C8() B--U-AX D--U-AX G--U-AX AJ-8 Phenyl-Hexyl G--U-AX AJ-8 PFP() D-8-U-AX AJ-88 HILIC G--U-AX AJ-88 for ID: - 9 mm * SecurityGuard Analytical Cartridges require holder, Part No.: KJ-8 SemiPrep SecurityGuard Cartridges require holder, Part No.: AJ-98 ** PREP SecurityGuard Cartridges require holder, Part No.: AJ-8 PREP SecurityGuard Cartridges require holder, Part No.: AJ-8 Phenomenex l WEB: 9

40 Australia t: + ()-98- f: + ()-98- auinfo@phenomenex.com Austria t: + ()-9- f: + ()-9- anfrage@phenomenex.com Belgium t: + () (French) t: + () 8 (Dutch) f: + ()-89 beinfo@phenomenex.com Canada t: + (8) -8 f: + () 8-8 info@phenomenex.com China t: f: +8 () - phen@agela.com Denmark t: f: + 8 nordicinfo@phenomenex.com Finland t: +8 ()9 89 f: + 8 nordicinfo@phenomenex.com France t: + () 9 f: + () 9 franceinfo@phenomenex.com Germany t: +9 ()-88- f: +9 ()-88- anfrage@phenomenex.com India t: +9 ()- f: +9 ()- indiainfo@phenomenex.com Ireland t: + () f: + -9 eireinfo@phenomenex.com Italy t: +9 f: +9 italiainfo@phenomenex.com Luxembourg t: + ()-8 f: + ()-89 nlinfo@phenomenex.com Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: + ()-8 f: + ()-89 nlinfo@phenomenex.com New Zealand t: + ()9-89 f: + ()9-89 nzinfo@phenomenex.com Norway t: + 8 f: + 8 nordicinfo@phenomenex.com Puerto Rico t: + (8) -HPLC f: + () 8-8 info@phenomenex.com Spain t: f: espinfo@phenomenex.com Sweden t: + ()8 9 f: + 8 nordicinfo@phenomenex.com United Kingdom t: + ()- f: + ()-9 ukinfo@phenomenex.com USA t: + () - f: + () 8-8 info@phenomenex.com All other countries Corporate Office USA t: + () - f: + () 8-8 info@phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR_W Terms and Conditions Subject to Phenomenex Standard Terms & Conditions, which may be viewed at www. phenomenex.com/termsandconditions. Trademarks Luna, Kinetex, and Strata are registered trademarks and SecurityGuard, Novum, Phenex, Axia, and MidBore are trademarks of Phenomenex. ACE is a registered trademark and Excel is a trademark of Advanced Chromatography Technologies Limited. Waters, ACQUITY, UPLC, and CORTECS are registered trademarks of Waters Corporation. Agilent and ZORBAX are registered trademarks of Agilent Technologies, Inc. Thermo Scientific is a registered trademark and Syncronis is a trademark of Thermo Fisher Scientific. Hypersil GOLD is a registered trademark of Thermo Hypersil-Keystone LLC. AkzoNobel and Kromasil are registered trademarks of AkzoNobel Pulp and Performance Chemicals AB. YMC is a registered trademark of YMC Co., Ltd. API is a trademark of AB SCIEX Pte. Ltd. AB SCIEX is being used under license. Supelco is a registered trademark and Titan is a trademark of Sigma-Aldrich Co. LLC. HALO is a registered trademark of Advanced Materials Technology, Inc. ("AMT"). Disclaimer Phenomenex is not affiliated with Advanced Chromatography Technologies Limited, Agilent Technologies, AkzoNobel, Thermo Fisher Scientific, YMC, Waters Corporation, Sigma-Aldrich, or AMT. Axia column and packing technology is patented by Phenomenex. U.S. Patent No.,, 8 Kinetex EVO is patented by Phenomenex. U.S. Patent Nos.,, and 8,8,8 and foreign counterparts. SecurityGuard is patented by Phenomenex. U.S. Patent No.,, CAUTION: this patent only applies to the analytical-sized guard cartridge holder, and does not apply to SemiPrep, PREP or ULTRA holders, or to any cartridges. Strata-X is patented by Phenomenex. U.S. Patent No.,9, Phenomenex, Inc. All rights reserved.

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1 APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there

More information

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns. For Far Greater UHPLC Column Performance... You Must Have Kinetex Core-Shell UHPLC Columns www.phenomenex.com/kinetex The UHPLC Core-Shell Advantage Kinetex Core-Shell Technology produces increased efficiencies

More information

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you! Core-Shell Technology NEW Kinetex enyl Biph Biphenyl TM S TM Selectivity that a C8 just can t give you! S Bip he ylhenyl Bnip Remarkable Separation Power Rugged and Reliable % Aqueous Stable Kinetex Core-Shell

More information

Preparative Chromatography Meets UHPLC

Preparative Chromatography Meets UHPLC Preparative Chromatography Meets UHPLC The Power of Kinetex Core-Shell Technology with the Performance of Piston Packed Prep Columns Ultra-High Efficiencies Ultra-Long Lifetimes NO Added Pressure Two Award

More information

Core-Shell Technology for Proteins and Peptides

Core-Shell Technology for Proteins and Peptides Core-Shell Technology for Proteins and Peptides Better BioSeparations on HPLC and UHPLC Systems www.phenomenex.com/aeris Aeris Core-Shell Technology Core-Shell Particles Precision Engineered for Protein

More information

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology. Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology Jeff Layne, Phenomenex, Inc. Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 951 USA With virtually

More information

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Yes You Can! New! Amazing EVO C18. Core-Shell Technology Core-Shell Technology Yes You Can! New! Amazing EVO C8 Develop robust methods from ph - Get improved peak shape for bases Easily reduce run times and increase sensitivity THE PAST Fully Porous You used

More information

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit Kinetex 5 µm Core-Shell Columns Deliver Significant Improvements in Chromatographic Efficiency and Resolution versus Traditional Fully Porous 5 µm Columns Philip J. Koerner and Jeff Layne Phenomenex, Inc.,

More information

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market Better UHPLC Performance Starts NW.7 µm Core-Shell * Columns The IRST and NLY sub- µm core-shell columns on the market Phenomenex India Laxmi Cyber City, Ground loor, B Block, Survey no: Kondapur, Hyderabad

More information

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance

More information

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm

More information

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology Core-Shell Technology Kinetex EVO C8 HPLC/UHPLC Core-Shell Columns Greater Polar Retention with % Aqueous Stability Robust Methods from ph - Improved Peak Shape for Bases NEW.7 µm NEW. µm µm Unconventionally

More information

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Michael McGinley, Deborah Jarrett, and Jeff Layne Phenomenex, Inc., 411 Madrid Avenue, Torrance, CA 91 USA Aeris WIDEPORE

More information

Protect Your Mass Spec

Protect Your Mass Spec Protect Your Mass Spec Sample Preparation Solutions for Biological Samples www.phenomenex.com/bioms Dirty Samples Could be Costing You Money and Sensitivity Biological samples contain a wide variety of

More information

Finally, a Solid Phase Extraction product for Drugs of Abuse

Finally, a Solid Phase Extraction product for Drugs of Abuse n io t c a r t x E e s a h P d li Finally, a So e s u b A f o s g u r D r fo product Imagine Only Needing 1 SPE Sorbent For All of Your Drugs of Abuse Extractions Extract over 11 drugs using the same sorbent

More information

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns Core-Shell Technology 11 HPLC Myths Uncovered & Why You Must Have Kinetex Core-Shell HPLC Columns 2.6 www.phenomenex.com/kinetex HPLC myths have been around since the early 19 s! From the one about the

More information

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput ULTIMATE HPLC/UHPLC CMB Kinetex Luna mega Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput NEW MEGA Core-Shell Technology Luna mega Luna mega PS Kinetex. Kinetex Luna mega Cutting

More information

METHAMPHETAMINE & AMPHETAMINE

METHAMPHETAMINE & AMPHETAMINE METHAMPHETAMINE & AMPHETAMINE Enantiomers from Urine Rapid and Accurate Chiral Separation Polysaccharide Chiral Chiral LC LC Columns and SFC PHEN-RUO-49 Revision: Lux 3 µm AMP Column High Efficiency LC/MS/MS

More information

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns Core-Shell Technology NEW Kinetex Whoa! I can even separate structural isomers! TMS TMS HPLC/UHPLC Core-Shell Columns Reduce Method Development Time by Days Greater Reproducibility than other PPs Glorious

More information

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1. APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,

More information

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD Determination of Sugars in Animal Feed using HPLC-ELSD Laura Snow, Zeshan Aqeel, Allen Misa and Scott Krepich Phenomenex, Inc., Madrid Ave., Torrance, CA 9050 USA Laura Snow Scientist- Phenologix Outside

More information

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite T-1154 APPLICATIS Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS Matthew Trass, Shahana Huq, Seyed Sadjadi, Sky Countryman and Zdravko

More information

PAIN PANEL. Research and Solutions

PAIN PANEL. Research and Solutions PAIN PANEL Research and Solutions Pain management drug use and abuse has increased significantly in recent years. The 21 National Survey on Drug Use & Health (NSDUH) reports that 17.3% of first-time drug

More information

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced SIMPLIFIED IRAL SEPARATIS Lux ellulose- Guaranteed Alternative to IRALEL D- Exceptional Quality Sensibly Priced Lux ellulose- ellulose tris(3,5-dimethylphenylcarbamate) This dimethyl cellulose selector

More information

APPLICATIONS TN Analytical Method

APPLICATIONS TN Analytical Method APPLICATIONS Simultaneous Determination of Antidepressants and Metabolites in Urine Using Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry (UHPLC-MS/MS) using a Kinetex Core-Shell

More information

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases T-1164 APPLICATIS Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases Marc Jacob, Liming Peng, Michael Klein, Tom eveland,

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns Shuguang Li, Sky Countryman, and Erica Pike Phenomenex,

More information

Hyper-fast & Super-rugged

Hyper-fast & Super-rugged Hyper-fast & Super-rugged UHPLC & HPLC columns FALL 2013 PRODUCT CATALOG Hyper-fast & Super-rugged UHPLC & HPLC columns he introduction of HALO columns, developed using innovative Fused-Core particle

More information

ACE C18-AR Use the Power!

ACE C18-AR Use the Power! combines the retention and separation characteristics of a C18 phase with the extra selectivity of an integral phenyl functional group. The combination provides extra resolving power for a wide variety

More information

Phospholipid Removal Solutions

Phospholipid Removal Solutions Remove Phospholipids Remove Protein No Method Development www.phenomenex.com/phree One Quick Method, Three Big Advantages 1 2 Remove Proteins that can clog HPLC columns Eliminate Phospholipids that cause

More information

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC New Luna Omega 1.6 µm UHPLC Coumns The Fina Word in Fuy Porous UHPLC Enhanced with 2 Years of Technoogy, Innovation, and Experience One of the word s eading HPLC brands, now enhanced for incredibe UHPLC

More information

Figure 1. Core-Shell Particle Technology

Figure 1. Core-Shell Particle Technology Purification of Chlorogenic cid from Green Coffee using Kinetex Core-Shell Technology in xia Preparative Formats Zeshan qeel Technical Magician Zeeshan loves to collect watches and the ack to the Future

More information

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction.

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction. Polymeric SPE Strata-X- Drug B Simplify Your Solid Phase Extraction QC Tested for Drugs of Abuse No Equilibration or Conditioning Required NEW! Drug B Plus for In-Well Hydrolysis www.phenomenex.com/strataxdrug

More information

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB: Exceed your Purification Goals Guaranteed The Axia Prep Column Advantage Extended column lifetime Reproducibility: column-to-column and batch-to-batch igher efficiency Improved peak shape Increased loadability

More information

Labs Across the World Are Advancing Their Protein Precipitation

Labs Across the World Are Advancing Their Protein Precipitation Phospholipid Removal Solutions Labs Across the World Are Advancing Their Protein Precipitation Achieve Cleaner Samples Extend HPLC Column Lifetime Improve Analyte Sensitivity Reduce Mass Spec Maintenance

More information

APPLICATIONS TN Materials and Methods

APPLICATIONS TN Materials and Methods APPLICATIONS A Simple, Fast, and Efficient HPLC Method for Sensitive, Accurate, and Reproducible Quantitation of Vitamin C in Human Plasma by Applying Impact Protein Precipitation Plate Technology with

More information

Restek Ultra II HPLC Columns

Restek Ultra II HPLC Columns Restek Ultra II HPLC Columns THE Choice for All U(HPLC) Systems November 2009 1 www.chromtech.net.au, sales@chromtech.net.au, Tel: 03 9762 2034, Fax: 03 9761 1169 Topics for Today Introducing Restek Ultra

More information

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes Application Guide PAIN PANEL Screen 41 compounds in under 4 minutes Solutions for large compound screens and individual compound classes such as benzodiazepines, opiates, and more Achieve resolution of

More information

Analytical and Preparative SFC Columns

Analytical and Preparative SFC Columns Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...

More information

Sepax Technologies, Inc.

Sepax Technologies, Inc. Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid

More information

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) APPLICATIONS A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE) Ann Montross Technical Specialist Ann enjoys cooking/baking and roasting her

More information

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse Keep It Clean Solid Phase Extraction Solutions for Drugs of Abuse Analysis Neutral Drugs of Abuse Basic Drugs of Abuse Strata -X-Drug B: Basic Drugs of Abuse Working with basic drugs? Here are 3 reasons

More information

ACE Excel UHPLC Columns

ACE Excel UHPLC Columns Excel UHPLC Columns info@ace-hplc.com Advanced Chromatography Technologies Ltd www.ace-hplc.com Australia & New Zealand contact: infor@winlab.com.au or call + 0 Outline Introduction Key Product Points

More information

The Raptor HILIC-Si Column

The Raptor HILIC-Si Column The Raptor HILIC-Si Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution

More information

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed! U.S. Patent No. 6, 162, 362 Column Protection for UHPLC, HPLC to PREP Protect HPLC columns and extend lifetime Virtually no change in chromatography Available in analytical, semi-prep, and preparative

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

Keep it Clean with Strata -X

Keep it Clean with Strata -X Simplified Solid Phase Extraction Solutions Neutral Compounds Acidic Compounds Basic Compounds Strong Acids (pk a < 2 Weak Acids (pk a 2-4 Neutral Compounds Weak Bases (pk a 8-10 Strong Bases (pk a > 10

More information

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS Introduction Drug analysis from whole blood is gaining popularity due to a more complete measurement

More information

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex.6 µm Core-Shell Technology Column Philip J. Koerner, Matthew Trass, and Jeff Layne Phenomenex, Inc., Madrid Ave.,

More information

A New Era in SFC Column Technology

A New Era in SFC Column Technology B TM A ew Era in SFC Column Technology Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level

More information

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky

More information

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity ACE CN-ES Combining CN polar selectivity with enhanced hydrophobicity Extended Spacer Extra Stability New stationary phase technology for UHPLC and HPLC separations Alternative polar selectivity for method

More information

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated Fast, Rugged Raptor Columns with Time-Tested Selectivity Selectivity Accelerated Stationary Phase: Biphenyl CH 3 Si CH 3 O Pure Chromatography www.restek.com/raptor The Raptor Biphenyl Column With Raptor

More information

Fortis Method Development Options

Fortis Method Development Options Method Dev Fortis Method Development Options Choice of Stationary phase functionality Based on Ultra pure silica Reversed Phase (RP) and Normal Phase (NP) options Fortis Ho - Polar endcapped C8 - Increased

More information

Agilent Technologies Prep LC Columns

Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies has always taken seriously its responsibility to ensure your success. That s why all our instruments and supplies

More information

APPLICATION TN Materials and Methods Reagents and Chemicals

APPLICATION TN Materials and Methods Reagents and Chemicals TN-8 APPLICATION Fast Analysis of Sucrose,, and Composition in Fruit Juices and Processed Beverages using Simplified HPLC Methodology Brian Rivera Product Manager In addition to chromatography, Brian also

More information

Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694

Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694 Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694 Ed Mauney, Hillel K. Brandes, William H. Campbell, Wayne K. Way, Richard A. Henry, David S. Bell, and Carmen T. Santasania

More information

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and

More information

Ultimate Core Performance to Maximize Your Investment

Ultimate Core Performance to Maximize Your Investment Thermo Scientific Accucore HPL olumns Phase Overview Ultimate ore Performance to Maximize Your Investment Phase Overview Founded on state-of-the-art ore Enhanced Technology and utilizing vast experience

More information

Separations. Sweet Sugar. Are in Your Future. New. Luna Omega SUGAR LC Column OMEGA

Separations. Sweet Sugar. Are in Your Future. New.   Luna Omega SUGAR LC Column OMEGA OMEGA Sweet Sugar Separations Are in Your Future New Luna Omega SUGAR LC Column Improved carbohydrate retention and separation with novel HILIC selectivity Enhanced lifetime with highly robust and efficient

More information

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm HPLC SMB smometry Euroline Eurospher II Eurospher II the logical choice After more than years on the market, our Eurospher stationary phase has established a reputation for being a first-class packing

More information

Effective Surface Area (m 2 /g) Pore Size (Å)

Effective Surface Area (m 2 /g) Pore Size (Å) n e w Ultra-High Performance on Any LC System Achieve sub- µm performance within HPLC backpressure limitations Substitute µm and µm columns for -x higher efficiency Obtain higher throughput without sacrificing

More information

Prep Columns. and Bulk Media. and Bulk Media

Prep Columns. and Bulk Media. and Bulk Media Prep Columns and Bulk Media Axia Columns...346-355 Process Chromatography...356-36 Bulk Media...356-36 Columns, Scout and Preparative...359-36 Sepra Bulk Sorbents... 36 Prep Columns and Bulk Media 345-36

More information

Abstract. Introduction

Abstract. Introduction A Fast Dilute-And-Shoot Method for Simultaneous 5-Hydroxyindoleacetic Acid (5-HIAA), Vanillylmandelic Acid (VMA), and Homovanillic Acid (HVA) LC-MS/MS Analysis in Human Urine By Shun-Hsin Liang and Sue

More information

C30 ISOMERS HAVE MET THEIR MATCH

C30 ISOMERS HAVE MET THEIR MATCH C30 ISOMERS HAVE MET THEIR MATCH INTRODUCING THE NEW! Built on proven Fused-Core particle technology, the is designed to deliver fast separations ideal for lipids and isomers compared to your C18. FEATURES

More information

Supported Liquid Extraction (SLE) For Food Applications

Supported Liquid Extraction (SLE) For Food Applications Supported Liquid Extraction (SLE) For Food Applications Novum Synthetic SLE Unique, Synthetic Sorbent that Provides Consistent, Reliable Results Strata DE Diatomaceous Earth SLE Cost-Effective, Guaranteed

More information

Gerry Hendrickx Regional Sales Manager Central Europe. Developments in Waters Column Chemistries : BEH Technology

Gerry Hendrickx Regional Sales Manager Central Europe. Developments in Waters Column Chemistries : BEH Technology Gerry Hendrickx Regional Sales Manager Central Europe Developments in Waters Column Chemistries : BEH Technology XTerra Columns: First Generation Hybrid Particles Initial Launch 1999 Advantages of XTerra

More information

Impurity Profiling of Carbamazepine by HPLC/UV

Impurity Profiling of Carbamazepine by HPLC/UV Application Note: 52049 Impurity Profiling of Carbamazepine by HPLC/UV Terry Zhang, Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela Hypersil GOLD Carbamazepine Drug Analysis

More information

2012 Waters Corporation 1

2012 Waters Corporation 1 An Introduction to Waters HPLC and ACQUITY UPLC Column Technologies for small molecule analysis Esa Lehtorinne Esa_Lehtorinne@waters.com Tel: +358-9-5659 5659 6288 Fax: +358-9-5659 5659 6282 Waters Finland

More information

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability ACE C8-AR A C8 bonded phase with unique selectivity Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and aromatic mixed mode interaction High efficiency µm, µm, µm and 0µm particles

More information

Raptor HILIC-Si: Simplify the Switch to HILIC

Raptor HILIC-Si: Simplify the Switch to HILIC Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed

More information

HICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies NEW PRODUCTS Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email: sales@hichrom.co.uk

More information

Dikma Technologies Inc.

Dikma Technologies Inc. Dikma HPLC / UHPLC Columns Selection Guide HPLC Column Selection Chart Sample MW Sample Solubility Separation Mode Dikma Recommended Column Page Fat Soluble Normal Phase Platisil NH 2 Platisil CN Platisil

More information

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology Kinetex. µm UHPLC Coumns The chosen core-she brand to drive UHPLC performance to the next eve Simpy Advantageous The band broadening (wide peaks) and engthy retention times of traditiona fuy porous products

More information

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable,

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Poor retention

More information

Thermo Scientific Hypersil BDS Columns

Thermo Scientific Hypersil BDS Columns Technical Guide Version 2 Thermo Scientific Hypersil BDS Columns Robust and rugged, delivering excellent reproducibility and peak symmetry Part of Thermo Fisher Scientific Thermo Scientific Hypersil BDS

More information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA

More information

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior InertSustain Phenylhexyl A ew Second Choice Column to Change Chromatographic Behavior Providing Alternative Selectivity to C8 Phases InertSustain Phenylhexyl columns are bonded with phenylhexyl groups,

More information

Raptor HILIC-Si: Simplify the Switch to HILIC

Raptor HILIC-Si: Simplify the Switch to HILIC Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed

More information

CANNABIS TESTING ACCESSORIES

CANNABIS TESTING ACCESSORIES CANNABIS TESTING ACCESSORIES HPLC/GC/Sample Prep www.phenomenex.com/cannabis Popular Accessories for Cannabis Testing Cannabis Testing Accessories Sample Preparation Vials Sample Preparation Phenex Syringe

More information

Ultra Columns. also available. ordering note

Ultra Columns. also available. ordering note : 3μm or 5μm particles; 100Å pore size Our broadest selection of stationary phases, including unique phases. High density bondings, for maximum retention. High-purity, Type B silica gives excellent peak

More information

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs APPLICATION Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs Seyed Sadjadi, Shahana Huq, Sean Orlowicz, and Laura Snow Phenomenex, 4 Madrid Avenue, Torrance,

More information

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column Diamond Analytics Technical Note: T131-1 Separation of Vitamin D and Vitamin D Metabolites on FLARE C1 MM (Mixed Mode) HPLC Column Introduction In this technical note, the versatility of the diamond-based

More information

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. Fast High peak capacity Low back pressure PROTEIN PEPTIDE UHPLC COLUMNS Put these new, high-performance

More information

SeQuant ZIC -HILIC For all who expect more...

SeQuant ZIC -HILIC For all who expect more... SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Poor

More information

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword   Pinnacle II Columns : 3μm or 5μm particles; 110Å pore size Silica at, for total control of quality and reproducibility. Excellent replacement for the original Hypersil material. Physical and chromatographic properties similar

More information

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) Michael Rummel, Matthew Trass, Michael Campognone, and Sky Countryman Phenomenex, Inc., 411 Madrid Avenue, Torrance,

More information

Comparison of a UPLC Method across Multiple UHPLC Systems

Comparison of a UPLC Method across Multiple UHPLC Systems Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid

More information

Dikma Technologies Inc.

Dikma Technologies Inc. Dikma HPLC / UHPLC Columns Selection Guide Dikma Technologies Inc. www.dikmatech.com HPLC Column Selection Chart Sample MW Sample Solubility Separation Mode Dikma Recommended Column Fat Soluble Normal

More information

LC-MS/MS Method for the Determination of Tenofovir from Plasma

LC-MS/MS Method for the Determination of Tenofovir from Plasma LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract

More information

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using 500 MG CLEAN UP CCX2 and LC-MS/MS

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using 500 MG CLEAN UP CCX2 and LC-MS/MS Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using 500 MG CLEAN UP CCX2 and LC-MS/MS UCT Part Numbers: CUCCX256 - Clean-Up CCX2 (C8 + Carboxylic Acid) 500mg/6mL

More information

Ultra Columns HPLC COLUMNS

Ultra Columns HPLC COLUMNS Acetaminophen, Narcotic Analgesics.............519 Aldehydes, Ketones...........................500 Beclomethasone.............................523 Corticosteroids..............................529 Explosives..................................501

More information

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using CLEAN UP CCX2 and LC-MS/MS

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using CLEAN UP CCX2 and LC-MS/MS Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using CLEAN UP CCX2 and LC-MS/MS UCT Part Numbers CUCCX256 Clean Up CCX2 (C8 + Carboxylic Acid) 500mg / 6mL SPE Cartridge

More information

GlycanPac AXR-1 Columns

GlycanPac AXR-1 Columns CHRMATGRAPHY GlycanPac AXR- Columns For High Resolution Glycan Analysis Product Specifications The Thermo Scientific GlycanPac AXR- columns are highperformance, silica-based HPLC columns for simultaneous

More information

YMC-Triart C18. Multi-layer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology

YMC-Triart C18.  Multi-layer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology YMC-Triart C18 Versatile hybrid silica based HPLC Column The Selectivity Company Multi-layer hybrid material for HPLC ph and temperature stability Innovative micro-reactor technology www.ymc.de 2 YMC-Triart

More information

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available ACE HILIC UHPLC and HPLC s For Reproducible Polar Analyte Separations Three HILIC Chemistries Available ACE HILIC s What is HILIC? Hydrophilic Interaction Liquid Chromatography (HILIC) was first described

More information

The LC Column Playbook

The LC Column Playbook The LC Column Playbook Mark Powell Applications Engineer Technical Support 1 Overview How do we achieve our goal: Resolution? Efficiency Particle size Column length Selectivity Bonded phase Mobile phase

More information

Am I getting the very best value from my UHPLC analyses?

Am I getting the very best value from my UHPLC analyses? Am I getting the very best value from my UHPLC analyses? Stephen Luke LC Columns Product Manager 1 Primary reasons for UHPLC use Very fast Very high resolution Column 2.1 x 50 mm Column 2.1 x 150 mm Run

More information